Page 201
Appendix G Troubleshooting Introduction The MK1200 troubleshooting is provided in three sections: •
Troubleshooting on page G-3 offers troubleshooting scenarios for the MK1200.
•
OS Upgrade Troubleshooting on page G-6 provides OS upgrade troubleshooting scenarios for the MK1200.
•
MK1200 Version Information on page G-7 describes how to identify the MK1200 version.
Troubleshooting Notes When configuring the MK1200 System Menu screens, save and reboot the MK1200 to apply the changes. To save some Control Panel changes across cold boot cycles, on the MK1200, select Start > Programs > Save Configuration (see Control Panel Configuration Parameters on page 3-20).
Page 202
G-2
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Troubleshooting •
MK1200 does not turn on on page G-3
•
MK1200 appears to lock up upon bootup on page G-3
•
MK1200 does not respond to polls from the host computer on page G-3
•
MK1200 does not send data to host computer on page G-3
•
Web Kiosk Software Suite does not work after making changes to the MK1200 on page G-3
•
Scanner does not recognize configuration bar codes on page G-4
•
Parameter changes made using System Menu were not retained after the MK1200 was re-booted on page G-4
•
Reg file values are not copied into the Registry at boot time on page G-4
•
The screen does not respond to pen input on page G-4
•
AirBeam fails to start; abstart.exe crashed at boot up on page G-4
•
Need to determine a device MAC address on page G-4
•
The wireless MK1200 does not retain its WEP Key encryption after a reboot on page G-4
•
After configuring the wireless MK1200 using the mkconfig.reg file, Mobile Companion does not automatically launch on page G-4
•
The Mobile Companion icon does not appear in the task tray on page G-5
•
When downloading files to the MK1200 from a .zip file using ActiveSync, a message displays indicating there is not enough free disk space to copy the application on page G-5
•
When downloading a large file over ethernet, IE issues an insufficient memory message on page G-5
•
When upgrading using a CF/PC card, the MK1200 cannot find files on the card on page G-5
•
Flash file system is corrupt on page G-5.
•
Copying large amount of files from CF or PC card to the application folder fails with error "Access is denied" on page G-5
•
After rebooting the MK1200, you can't navigate using the buttons on page G-5
Page 203
Troubleshooting
G-3
Table G-1 Troubleshooting
Problem
Possible Causes
Possible Solutions
MK1200 does not turn on
No power to the MK1200.
- Power through AC outlet - Connect the Symbol approved power supply to an AC power source and to the MK1200 power connector. See Figure 1-3 on page 1-5. - Power through power-over-Ethernet - Connect 8-wire Ethernet cable to MK1200 LAN port. - Connect other end of Ethernet cable to Bias-T Power-Over-Ethernet (POE). - Connect Bias-T POE power supply to an AC outlet. - Perform continuity check on the Ethernet cable.
MK1200 appears to lock up upon bootup
A utility with no user interface was specified as the first user application, or user application failed to run.
Either specify no user application, or a UI-based application as the first user application. If no user application is specified, Explorer.exe is used. Note: this is a substitution of Explorer.exe as the user application, not protected mode.
MK1200 does not respond to polls from the host computer
No communication between the host and MK1200.
Check cables to the MK1200. Ensure the MK1200 address is the address the host is polling. Check communication parameters. Open a command window using Start > Programs > Command and type ipconfig to list the status of all radio and ethernet interfaces.
MK1200 does not send data to host computer
Web Kiosk Software Suite does not work after making changes to the MK1200
MK1200 is not programmed to work with the host.
Check setup communication parameters.
MK1200 is not connected to the host.
Check cables to host computer.
Web Kiosk Software Suite parameter settings inconsistent with latest program changes and/or corrupt files.
Locate and delete the files associated with the Web Kiosk Software Suite (in the My Computer/Application folder). Then reload the files associated with the Web Kiosk Software Suite. See Installing the Web Kiosk Software Suite on page 6-3.
Page 204
G-4
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Table G-1 Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
Scanner does not recognize configuration bar codes
The scan driver does not support parameter bar code scanning.
Configure the scanner using scanning C API or Active X scanner object.
Parameter changes made using System Menu were not retained after the MK1200 was re-booted
Parameter changes were not saved.
See Setting Defaults Using the System Menu on page 3-5.
Reg file values are not copied into the Registry at boot time
More than one .reg file and duplicate registry entries are present.
Review all .reg files in /Application and /Platform and ensure they have no conflicts.
The screen does not respond to pen input
The screen is not properly calibrated, or is off center.
See Stylus Settings/Touch Screen Calibration on page 3-23
AirBeam fails to start; abstart.exe crashed at boot up
System Menu or RDM is used to enable DHCP receive options.
Do not use the System Menu or RDM to enable DHCP receive options 1, 3, 6, 15, 44, 46, 47, 66, and 67. They are already enabled in dhcpoptions.reg as a part of the AirBeam package. Refer to AirBeam documentation for this configuration.
Need to determine a device MAC address
N/A
Open Start > Programs > CommandPrompt. Type ipconfig /all to display the MAC address next to ‘address’.
The wireless MK1200 does not retain its WEP Key encryption after a reboot
Encryption keys not saved in spectrum24.reg or Aegis.reg file in the Application partition.
Set encryption keys using Mobile Companion, then use the Save Spectrum24 Settings or Save Aegis Settings tool to save them. Check communication parameter settings. Open a command window using Start > Programs > Command and type ipconfig to list the status of all radio and ethernet interfaces.
After configuring the wireless MK1200 using the mkconfig.reg file, Mobile Companion does not automatically launch
Incorrect Profile Name in the Mobile Companion Mode tab.
Assign the profile name “Default” in the Mode tab. This field is case-sensitive - enter this as a capital “D” and lower case “efault”. Apply all settings desired, including encryption keys, to this profile. Save the configuration.
Page 205
Troubleshooting
G-5
Table G-1 Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
The Mobile Companion icon does not appear in the task tray
Poor RF card connection or bad RF card.
Remove the PCMCIA card cover (see Installing/Removing the RF Card on page 2-16). Press the card ejector button to release the card, then press the card back into its connector to secure it in place. Reboot the MK1200. If the Mobile Companion icon still does not appear in the task tray, replace the RF card.
The radio software is not present in the \platform folder.
Verify presence of radio software or re-install \Platform partition software.
When downloading files to the MK1200 from a .zip file using ActiveSync, a message displays indicating there is not enough free disk space to copy the application
Files cannot download directly from a .zip file.
Extract/unzip the files to the host computer, then transfer the unzipped files to the MK1200 using ActiveSync.
When downloading a large file over ethernet, IE issues an insufficient memory message
For some file types, IE requires free RAM equivalent to twice the file's size.
This is an IE limitation.
When upgrading using a CF/PC card, the MK1200 cannot find files on the card
The CF/PC card is not formatted properly for the MK1200.
Format the CF/PC card as FAT16.
Flash file system is corrupt
Reset or power loss during write to file system.
Format file system partition using Start >
Copying large amount of files from CF or PC card to the application folder fails with error "Access is denied"
Archive bit of the folder properties set.
Clear the archive bit of folder properties.
After rebooting the MK1200, you can't navigate using the buttons
In the MK1200, by default, the focus is not set to desktop after a reboot.
Tap the touch pad once.
Settings > Control Panel > Storage Manager, and re-install partition data.
If problems still occur, see MK1200 Version Information on page G-7 for system information before calling for service help.
Page 206
G-6
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
OS Upgrade Troubleshooting •
Monitor Upgrade Troubleshooting on page G-6.
•
Partition Table Upgrade Troubleshooting on page G-6
•
Command File Upgrade Troubleshooting on page G-6 NOTE
If OS upgrading repeatedly fails when using a CF card, use the Fat-16 system to format the CF card before saving the upgrade files.
Table G-2 OS Upgrade Troubleshooting
Problem
Possible Causes
Possible Solutions
Downloading Message, error screen
Monitor upgrade error.
Remove power from the MK1200, and restore power to reboot the MK1200. Hold the A button during the reboot. The IPL main menu displays. Repeat the monitor upgrade procedure.
MK1200 does not boot after performing a monitor update
Monitor upgrade failure.
Failures during the monitor upgrade often render the MK1200 inoperable. If the MK1200 does not boot after performing a monitor update, contact the Symbol Global Customer Interaction Center.
Monitor Upgrade Troubleshooting
Partition Table Upgrade Troubleshooting Downloading Message, error screen
Partition table upgrade error.
Remove power from the MK1200, and restore power to reboot the MK1200. Hold the A button during the reboot. The IPL main menu displays. Repeat the partition table upgrade procedure.
Data Abort Exception Error
Partition table upgrade error.
Remove power from the MK1200, and restore power to reboot the MK1200. Hold the A button during the reboot. The IPL main menu displays. Repeat the partition table upgrade procedure.
Command File Upgrade Troubleshooting The mon> error message displays
Command file upgrade error.
Remove power from the MK1200, and restore power to reboot the MK1200. Hold the A button during the reboot. The IPL main menu displays. Repeat the partition table upgrade procedure.
Page 207
Troubleshooting
G-7
MK1200 Version Information If an MK1200 is configured to launch an application on power-up, bypass this upon booting to access the Windows® CE Desktop. See Accessing the Windows® CE Desktop on page 7-7. 1.
From the Windows® task bar, select Start > Settings > Control Panel.
2.
Select MK1200 identification from the Control Panel window to view the following information:
• Device name • Description • OS version • Monitor version • Display type • Memory sizes. The Remote Device Manager (RDM) provides more detailed version information. See Monitoring MK1200s on a Network on page 4-15.
Page 208
G-8
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide