Page 189
Appendix F OS Upgrade Procedures Introduction MK1200 operating system upgrade procedures enable software updates and/or feature enhancements. This appendix provides upgrading instructions using a CF/PC card and the Initial Program Loader (IPL). To upgrade the MK1200 operating system: 1.
Review Upgrade Requirements on page F-2.
2.
Perform Monitor Upgrade on page F-4.
3.
Perform Partition Table Upgrade on page F-6.
4.
Perfrom Command File Upgrade on page F-7.
Page 190
F-2
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Upgrade Requirements Hardware Requirements •
CF or PC storage card with the appropriate upgrade files. NOTE
•
Symbol recommends using a freshly formatted CF/PC card for storing the upgrade files. Format the CF/PC card using the FAT file system in the host computer, then copy the upgrade files to the CF/PC card. The upgrade may fail if the CF/PC card contains a corrupt file system. The MK1200 is equipped with a PCMCIA slot only. This slot is used to connect the Spectrum24 radio card in MK1200 devices with a wireless facility. You must remove this card before upgrading. Use a CF card with a CF/PC card adapter.
ESD mat and equipment required to properly ground the operator. CAUTION
NOTE
When removing an access cover, follow proper ESD precautions to avoid damaging sensitive components. These include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded. Failure to apply proper ESD precautions can damage the MK1200 and void the warranty.
The MK Series includes two different platforms and operating files based on operating systems for the MK1200 (wired) versus the MK1250 (RF).
Software Requirements The files required to upgrade the MK12xx include: •
Command file for the MK1200:
• PC_MK1200_XXX.mcf •
Command file for the MK1250:
• PC_MK1250_XXX.mcf •
The following partition files:
• Monitor file: 11xxc42Monxxxx.bgz • OS file: 12xxc42OSxxxxxx.bgz • Platform file: 11xxc42Plat32Mxxx.hex • Partition Table file: 11xxc42Pt32Mxxx.hex • Application Partition file: 11xxc42App32Mxxx.hex • Splash Screen file: 12xxc42cSplxxx.hex
Procedural Requirements •
Monitor Upgrade on page F-4
•
Partition Table Upgrade on page F-6
•
Command File Upgrade on page F-7
•
Calibrating the Screen on page F-10 (optional).
Page 191
OS Upgrade Procedures
F-3
IPL Menu Navigation IPL is a menu-based method of downloading partitions to non-volatile storage (flash) on the MK1200. You can download the following partitions: •
OS Partition
•
Platform Partition
•
Application Partition
•
Partition Table
•
Splash Screen
•
Monitor.
Use the MK1200 buttons to navigate IPL menus and make selections. The buttons and their functions are shown in Figure F-1.
A Button Scroll Down
B Button Scroll Up
C Button Select Menu Option
Figure F-1 Button Functions
OS Upgrade To upgrade the MK1200 operating system using a CF/PC card, see the following sections to perform monitor, partition table, and command file upgrades. To begin the operating system upgrade: 1.
Power off the MK1200.
2.
Remove the PCMCIA access cover (see Figure 1-1 on page 1-3).
3.
Insert the PC card into the PCMCIA card slot.
Page 192
F-4
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Monitor Upgrade
NOTE
A failure during the monitor upgrade can cause the MK1200 to become inoperable.
To perform a monitor upgrade: 1.
Enter IPL mode by powering on the MK1200 while holding the A button. The Initial Program Loader main menu displays. Initial Program Loader Timer off Platform Application Windows CE Monitor Splash Screen Partition Table Command File System Reset Auto Select
Figure F-2 IPL Main Menu 2.
From the Initial Program Loader main menu, press the A or B button to highlight Monitor.
3.
Press the C button to select Monitor. The Select Transport menu displays. Select Transport Timer off PC Card Scanner/Printer - Serial Previous Top
Figure F-3 Select Transport Menu 4.
Press the A or B button to select the file media source and highlight PC Card.
Page 193
OS Upgrade Procedures
5.
Press the C button to select PC Card. The Select File Name menu displays. Select File Name Timer off 11xxc42Monxxxx.bgz 12xxc42OSxxxxxx.bgz 11xxc42Plat32Mxxx.hex 11xxc42Pt32Mxxx.hex 11xxc42App32Mxxx.hex 12xxc42cSplxxx.hex Previous Top
Figure F-4 Select File Name Menu 6.
Press the A or B button to highlight the monitor upgrade file, 11xxc42Monxxxx.bgz.
7.
Press the C button to select 11xxc42Monxxxx.bgz. The Download File? menu displays. Download File? Timer off Download Cancel Show Parms Previous Top
Figure F-5 Download File? Menu 8.
Press the A or B button to highlight Download.
9.
Press the C button to initiate the monitor file download. When the monitor upgrade begins, the following message displays. Downloading: Monitor Via PC Card 11xxc42Monxxxx.bgz ############# 100%Your terminal needs to be rebooted. Please press button A to reboot.
Figure F-6 Monitor Upgrade, Downloading Message NOTE
If an error occurs, remove power from the MK1200 and restore power to reboot the MK1200. Hold the A button during the reboot. The IPL main menu displays. Repeat the Monitor upgrade procedure.
10. When the new monitor is successfully loaded, the MK1200 prompts to press a button, then reboots. 11. Continue the OS upgrade by holding the A button during the reboot to display the IPL main menu.
F-5
Page 194
F-6
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
12. Proceed to Partition Table Upgrade.
Partition Table Upgrade To perform a partition table upgrade: 1.
From the IPL main menu, press the A or B button to highlight Partition Table.
2.
Press the C button to select Partition Table. The Select Transport menu displays. Select Transport Timer off PC Card Scanner/Printer - Serial Previous Top
Figure F-7 Select Transport Menu 3.
Select the file media source by pressing the A or B button to highlight PC Card.
4.
Press the C button to select PC Card. The Select File Name menu displays. Select File Name Timer off 11xxc42Monxxxx.bgz 12xxc42OSxxxxxx.bgz 11xxc42Plat32Mxxx.hex 11xxc42Pt32Mxxx.hex 11xxc42App32Mxxx.hex 12xxc42cSplxxx.hex Previous Top
Figure F-8 Select File Name Menu 5.
Press the A or B button to highlight the partition table upgrade file, 11xxc42Pt32Mxxx.hex.
6.
Press the C button to select 11xxc42Pt32Mxxx.hex. The Download File? menu displays. Download File? Timer off Download Cancel Show Parms Previous Top
Figure F-9 Download File? Menu 7.
Press the A or B button to highlight Download.
Page 195
OS Upgrade Procedures
8.
F-7
Press the C button to select Download and initiate the partition table upgrade. When the partition table upgrade begins, the following Downloading message displays. Downloading: Partition Table Via PC Card 11xxc42Pt32Mxxx.hex Result was Success! Please press Enter to continue
Figure F-10 Partition Table Upgrade, Downloading Message NOTE
9.
If an error screen displays, remove power from the MK1200 and restore power to reboot the device. Hold the A button during the reboot. The IPL main menu displays. Repeat the Partition Table upgrade procedure.
When the message Please press Enter to continue displays, press the C button to continue the OS upgrade and proceed to Command File Upgrade.
Command File Upgrade To perform a command file upgrade: 1.
From the IPL main menu, press the A or B button to highlight Command File.
2.
Press the C button to select Command File. The Select Transport menu displays. Select Transport Timer off PC Card Scanner/Printer - Serial Previous Top
Figure F-11 Select Transport Menu 3.
Select the file media source by pressing the A or B button to highlight PC Card.
4.
Press the C button to select PC Card. The Select File Name menu displays. Select File Name Timer off PC_MK1200_XXX.mcf PC_MK1250_XXX.mcf Previous Top
Figure F-12 Select File Name Menu
Page 196
F-8
MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
5.
Select the command file by pressing the A or B button to highlight the appropriate file to download. NOTE
6.
If the mon> error message displays, remove power from the MK1200 and restore power to reboot the device. Hold the A button during the reboot. The IPL main menu displays. Repeat the Command File upgrade procedure.
Press the C button to select the file. The Download File? menu displays. Download File? Timer off Download Cancel Show Parms Previous Top
Figure F-13 Download File? Menu 7.
Press the A or B button to highlight Download.
8.
Press the C button to select Download and initiate the command file upgrade.
Page 197
OS Upgrade Procedures
9.
When the command file upgrade begins, the following message displays. Downloading: Command File Via PC Card PC_MK1200_XXX.mcf Obtaining script file from given transport . . . ################### 100% Begin script execution ----------------------------------------------------------Partition Table ################### 100% Download complete in 0.656 seconds (12487 bytes/second) ---------------------------------------------------------------Splash Screen ################### 100% Download complete in 3.257 seconds (94131 bytes/second) ---------------------------------------------------------------Platform ################### 100% Download complete in 14.337 seconds (365000 bytes/second) ---------------------------------------------------------------Application ################### 100% Download complete in 39.38 seconds (718000 bytes/second) ---------------------------------------------------------------################### 100%Your terminal needs to be rebooted. Please press button A to reboot.
Figure F-14 Command File Upgrade, Downloading Message NOTE
If an error screen displays, remove power from the MK1200 and restore power to reboot the device. Hold the A button during the reboot. The IPL main menu displays. Repeat the Command File upgrade procedure.
10. Press and release button A to perform a warm boot. When the desktop displays, remove power from the
MK1200. Remove PC card and replace the PCMCIA access covers (see Figure 1-2 on page 1-4).
F-9
Page 198
F - 10 MK1200 MicroKiosk for CE .NET 4.2 Product Reference Guide
Calibrating the Screen Use the Calibration screen to align the touch screen: 1.
Remove and restore power to the MK1200 to reboot.
2.
From the Windows CE Desktop window, press buttons A, C, and D simultaneously to display the Calibration screen.
Figure F-15 Calibration Screen NOTE
To access the Calibration screen from the Windows CE Control Panel, tap Start > Settings > Control Panel. Double-tap the Stylus icon, tap the Calibration tab, and tap the Recalibrate button. The Calibration screen displays.
3.
Carefully press and briefly hold the stylus tip on the center of the Calibration screen target. Repeat the procedure as the target moves and stops at different locations on the screen.
4.
The Confirm Calibration Resave screen displays. Press the left two buttons (A and B) to accept the new settings or press the right two buttons (C and D) to retain the existing calibration settings.
Figure F-16 Save Settings, Calibration Screen
Page 199
OS Upgrade Procedures F - 11
Update Corona Scanner Engine Firmware Unzip ScanflashVX.X_CE4.x.zip file and copy its contents to the root "\" directory on the MK1200 device. The zip file contains: •
Corona scanner firmware binary image file (*.FDL)
•
ScanFlash.exe
•
ScanFlash.bat.
•
Execute the ScanFlash.bat file to update the Corona Scanner Engine firmware. NOTE
Do not disrupt power to the MK1200 while updating scanner engine firmware. Doing so can damage the scanner engine.
Page 200