Page 537
Configuring the Mobile Computer
11. The Download File? menu appears. Download File?
Download Cancel Show Parms Previous Top
Figure 14-11. Download File? Menu
14-19
Page 538
14-20
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
12. Use the up and down scroll buttons to select Show Parms to verify the file to download. Press Enter to display the Parameters screen.
Download: "Partition Name" via "Device Parameters" Press Enter to Continue
Figure 14-12. Parameters Screen Partition Name is the name of the partition selected in the Initial Program Loader menu. Device Parameters is the device selected in the Select Transport menu with the baud rate for serial downloads, or DHCP address for wireless downloads. 13. Press Enter to return to the Download File? menu.
Page 539
Configuring the Mobile Computer
14. Use the up and down scroll buttons to select Download. Press Enter. The Downloading screen appears.
Downloading: Partition Name Device Parameters Device Status
Figure 14-13. Downloading Screen Before the download starts, if Serial was selected in the Select Transport menu, Waiting for Data appears in the Device Status field. If Wireless S24XX was selected in the Select Transport menu, the IP address appears in the Device Status field. 15. On the development computer, click Load on the TCM toolbar. The Load Terminal window Serial tab appears.
Figure 14-14. Load Terminal Window - Serial and Ethernet Tabs
14-21
Page 540
14-22
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
16. For Serial port connections, click the Serial tab and select the Image Files To Load, Comm Port and Baud Rate from their respective drop-down lists. For Wireless connections, click the Ethernet tab. A list of available devices and their IP addresses appear. Only those devices placed into the Wireless transport mode of IPL appear in this dialog. Select the files to download and the device to receive the files. To load a device, the status must be "Active." 17. Click Download to begin the operation. 18. During download, the Downloading screen on mobile computer displays the Device Status and a progress bar. 19. When complete, Device Status displays Result was Success, or in the case of an error, the cause of the error. 20. On completion, press Enter to return to the IPL menu to select the next partition to download. 21. To exit IPL, select the System Reset item from the IPL menu (see Figure 14-7 on page 14-13).
Page 541
Configuring the Mobile Computer
TCM Error Messages TCM validates the cells in the partition table when the Execute button is clicked. Cells highlighted in red contain an error. Partition loading is disabled until all errors are corrected.
Table 14-3. TCM Error Messages Error
Description/Solution
Failed to build images: flash file system DLL not loaded!
TCM could not load the DLL required to build images for the targeting flash file system. Reinstall TCM or recover the DLL.
Failure finding directory xxx
Building process failed because directory xxx was not found.
Failure creating volume
Building process failed because a certain disk volume could not be created.
Failure adding system file to image
Build process failed because TCM failed to add a certain system file to the disk image.
INVALID PATH
The path for the image file to build is not valid.
Nothing Selected To Build
In the Config Build window, no item is selected to build.
Illegal ESS ID
In the Build ESSID Partition window, no ESS ID was entered or the ESS ID entered was illegal.
Disk Full
TCM failed to create Hex image file at the selected path. Check available disk space.
Target Disk Full
Build process failed because TCM failed to add file to the image of a disk volume. Remove some files or increase the disk size.
Hex file is READ ONLY
The Hex image file to be created exists and is read-only. Delete the existing file or change its attribute.
Error opening the file xxx with write access
TCM could not open file xxx with write access. Check if file is in use.
Failure creating binary file
TCM failed to open/create an intermediate binary file.
Hex File To load is missing or invalid
In Load Terminal window, the file selected to load has invalid status.
Could not locate mobile computer While loading the Script Properties window, TCM could not find the TCM.ini section name in TCM.ini file corresponding to the mobile computer type specified by the current opening script. Either TCM.ini or the script file is invalid. Incorrect disk sizes in TCM.ini file The total disk size specified in the script does not match the total disk size defined in the corresponding TCM.ini section. Check if the script is corrupt or the TCM.ini has changed after the script was created. INVALID DIRECTORY
In Script Properties window, the selected System File Path is not a valid directory.
14-23
Page 542
14-24
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
Table 14-3. TCM Error Messages (Continued) Error
Description/Solution
One of the disk sizes is one sector In Script Properties window, one of the disks is too small (one sector in size). This may in size cause problem while building images, especially when cushion is enabled. Increase the disk size. INVALID VOLUME NAME
In Script Properties window, one of the volume labels is not valid.
Corrupt TCM.INI file! (Invalid value of VolumeDivisor)
The VolumeDivisor entry is missing or invalid in the TCM.ini. Reinstall TCM or recover TCM.ini.
Invalid version of TCM script file
The TCM script was not created by this version of TCM.
Corrupt or missing TCM.ini file
TCM could not find TCM.ini file.
FAILED CONNECTION TO COM PORT (Could not get status)
While downloading images to mobile computer, TCM failed to connect to the selected COM port. Check if the COM port is free and is properly configured.
FAILED CONNECTION TO While downloading images, TCM failed to connect to the mobile computer. Check if TERMINAL (Terminal Not the correct flow control protocol is selected and the mobile computer is properly Connected Properly/Terminal Not connected and is in a listening state. Ready to Receive)
Page 543
Configuring the Mobile Computer
IPL Error Detection While receiving data, IPL performs many checks on the data to ensure that the data is received correctly. If an error is detected, IPL immediately aborts the download, and reports the error on an error screen. Error screens may vary depending on the action being performed. A sample error screen may look like the screen pictured below:
Downloading: Platform via Serial Port 115200 Error # -2 : Messages: Cancelled by user
Press any key to continue
Figure 14-15. IPL Error Screen This error message screen displays until you press any key. Once the screen is acknowledged, IPL returns to the Initial Program Loader main menu to wait for a new selection. To find the probable cause of the error, use the error number and/or the error text displayed on the screen to look up the error in Table 14-4..
Table 14-4. IPL Errors Error Text
Error Number
Probable Cause
Unknown error
-1
A general error occurred. Retry the download. If the failure persists, it is most likely due to a hardware failure; the mobile computer requires servicing.
Cancelled by user
-2
The user canceled the download.
14-25
Page 544
14-26
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
Table 14-4. IPL Errors (Continued) Error Text
Error Number
Probable Cause
Can't open the source
-7
An error occurred opening the source device (either radio card or Serial port). Check source device connectivity and retry.
Can't open the destination
-8
An error occurred opening the destination device (either flash ROM or Power Micro). Retry the download. If the failure persists, it is most likely due to a hardware failure; the mobile computer requires servicing.
Can't read from the source device
-9
The source device (either radio card or Serial port) could not be read from. Check source device connectivity and retry.
Can't write to the destination device
-10
The destination device (either flash ROM or Power Micro) could not be written to. Retry the download. If the failure persists, it is most likely due to a hardware failure; the mobile computer requires servicing.
Transmission checksum error
-11
An error occurred during transmission from the source device (either radio card or Serial port) and the checksum check failed. Check source device connectivity and retry.
Readback checksum error
-12
A checksum, generated from reading back data that was written to the destination device, was incorrect. An error during transmission or a write error to the destination device could cause this.
There is no more heap space available
-14
There is no more heap space available for the download procedure. Restart IPL and retry the download. If the failure persists, contact service with details of what is being downloaded.
Insufficient data available to complete record
-21
A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX file format.
Invalid Symbol HEX file
-23
A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX file format.
Unrecognized or unsupported HEX record
-24
The Symbol HEX file being downloaded contains an invalid or unrecognized HEX record. Ensure the file is in proper Symbol HEX file format.
Page 545
Configuring the Mobile Computer
Table 14-4. IPL Errors (Continued) Error Text
Error Number
Probable Cause
Invalid data in HEX file
-25
The Symbol HEX file being downloaded contains invalid data. Ensure the file is in proper Symbol HEX file format with valid HEX data.
Exceeded max size
-26
The download file is too large to fit into the space allocated for it. Either make the file smaller or increase the space allocated for it by altering the partition table.
Partition is not valid on this device
-27
The downloaded file specifies a partition entry that does not exist on the device. Only download files that are valid for this device, or change the partition table so that the new file is valid on the device.
Wrong destination code
-28
A specific partition was chosen from the Main Menu (not Auto Select) but the file selected for download was for another partition. Ensure that the partition selected from the Main Menu matches the file selected for download.
File type does not support IPL Auto Select
-29
Monitor, Power Micro and Partition Table cannot be loaded with Auto Select. Select the appropriate area, and try again.
Non-contiguous record found
-30
A Symbol HEX file download was attempted but the HEX file is invalid. Ensure the file is in Symbol HEX file format.
Timed Out - No data
-31
IPL was waiting for data from the source device but timed out before receiving any. Check the source device connectivity and retry.
Fail: Buffer Overrun
-32
The serial port device could not keep up with incoming data. Retry the serial download with a lower baud rate.
Partition Table not Valid
-33
The size of flash memory is different than that described in the partition table. Retry the download with the correct partition table file.
Invalid file format
-34
The file format is invalid. Only Symbol HEX files are supported by IPL.
14-27