Page 528
14-10
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
Opening a New or Existing Script A script file can be created from scratch or based on an existing script file. Click Create to create a new script or click Open to open an existing script (for example, a script provided in the DCP for MC9000w). If an existing script is opened and changes are made, saving the changes overwrites the original script. To use an original or Symbol supplied standard script as a base and save the changes in a new script, use the Save As function to save the script using a different file name.
Updating TCM 1.X Scripts Script files that were created with older versions of TCM can be upgraded to TCM 2.0 scripts. Click Open to open an existing script created with an older version of TCM. The Conversion window appears automatically.
Figure 14-4. Conversion Window - Upgrading to TCM 2.0
Copying Components to the Script Script contents are managed using standard file operations such as New Folder, Delete and Rename. Items can be added to the script by clicking files and folders in the File Explorer window and dragging them to the Script window. The File Explorer window supports standard windows; multiple files may be selected by clicking while holding the SHIFT or CTRL keys.
Saving the Script Modifications to a script file can be saved using the Save or the Save As function. Saving changes to an existing script writes over the original script. To use a Symbol-supplied standard script as a base and save the changes in a new script, use the Save As function.
Page 529
Configuring the Mobile Computer
Building the Image Once the script is created, the hex image defined by the script can be built. As part of the build, TCM performs a check on the script which verifies that all files referenced in the script exist. This check is important for previously created scripts to ensure that files referenced in the script are still in the designated locations. To build scripts: 1. Click Build on the TCM toolbar. The Configure Build window appears.
Figure 14-5. Configure Build Window 2. Select the items (partitions) to build using the check box(es) to the left of each named partition. 3. The Build Path defines where to store all built partitions. 4. Select (hex image) COMPRESSION to reduce the size and speed up the download. 5. Click OK and follow the on-screen instructions.
14-11
Page 530
14-12
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
If one of the partitions being built is the ESSID, a prompt appears requesting the ESSID value. Deselect the HR (High Rate) check box when building ESSID images for a device with an FH radio.
Figure 14-6. Build ESSID Partition Window If one of the partitions being built is the Splash Screen, a prompt appears requesting both the source Bitmap file and the destination HEX file. 6. A check is performed and if there are no errors, the partition hex files are created. If the build fails, the hex files are not be created and TCM displays an error message. Two of the most common reasons for a build failure are: •
•
Files defined in the script can not be found. This error can occur when the files referenced by the script are no longer stored on the development computer or the folders where they are stored were renamed. The total amount of flash memory space required by the script exceeds the image size. To correct this, reduce the number of files in the partition or increase the size of the partition. See Defining Script Properties on page 14-8 for more information about setting the image size appropriately.
Sending the Hex Image Once the hex file is built, it can be downloaded to the mobile computer. To load the hex files on to the mobile computer: 1. For downloads using a serial connection, connect the mobile computer to the development computer using the Single Slot Serial/USB cradle or CAM. 2. Press and hold the left scan button and the Power button simultaneously until the mobile computer resets into IPL.
Page 531
Configuring the Mobile Computer
The mobile computer must be inserted in the cradle or attached to the CAM, both with their appropriate power supplies connected to a power source, for the mobile computer to reset into IPL.
3. When the Initial Program Loader menu appears, release the scan and Power buttons. Initial Program Loader Platform Application PRIMFIRM SECFIRM ESSID Config Block Windows CE Monitor Rom Files Splash Screen Power Micro Partition Table System Reset Auto Select
Figure 14-7. Initial Program Loader (IPL) Menu The Rom Files menu option is for internal use only.
To insure a successful download, do not remove power from the mobile computer while in IPL mode. CAUTION
14-13
Page 532
14-14
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
4. Choose Auto Select or use the up and down scroll buttons to select the partition to download, then press Enter.
Table 14-2. IPL Menu Partitions Partition Name
Description
Platform
Contains the files in the Platform folder.
Application
Contains the files in the Application folder.
PRIMFIRM
Contains the primary radio firmware for the Spectrum24 HR radio card. Note: These partitions must be loaded to use wireless downloads through IPL with the HR radio. They are only used by IPL and are not required by the Operating System or the S24 FH radios.
SECFIRM
Contains the secondary radio firmware for the Spectrum24 HR radio card. Note: These partitions must be loaded to use wireless downloads through IPL with the HR radio. They are only used by IPL and are not required by the Operating System or the S24 FH radios.
ESSID
Identifies the ESSID, used for wireless downloads. Note: This partition specifies the ESSID to be used for IPL downloads via all S24 radios. If the partition is not present, then an ESSID of 101 is assumed. This partition is only used by IPL and is not required by the Operating System.
Config Block
Contains information to correctly configure the Operating System for the mobile computer. This information is loaded by the manufacturer. Note: Great care should be taken to ensure that an incorrect config block is not loaded into the mobile computer. Loading an incorrect config block prevents the correct operation of the computer.
Windows CE
Contains the operating system for the mobile computer.
Monitor
Contains the Monitor and IPL programs.
Rom Files
This partition is for internal use only.
Splash Screen
Contains the splash screen that displays while booting the mobile computer. Note: Splash screens are generated from .bmp images and must be less than or equal to 240 pixels wide and 296 pixels deep. For mono displays, the bmp image must be 4 bpp and for color screens the color depth must be 8 bpp. Note: 8 bits per pixel only applies to splash screen images. Once Windows CE is running, the color density is 16 bits per pixel.
Power Micro
The Power Micro is a small computer contained within the mobile computer that controls several system resources. In the unlikely event that the Power Micro Firmware needs updating, selecting this item allows the device to be programmed.
Page 533
Configuring the Mobile Computer
Table 14-2. IPL Menu Partitions (Continued) Partition Name
Description
Partition Table
Contains the partition information for all other partitions. Note: The partition table should never need changing unless the sizes of the platform and application images are changed within TCM. If this is done, then the new partition table should be loaded first, followed by both platform and application in any order.
System Reset
Selecting this item provides a simple method to exit IPL and to boot the operating system.
Auto Select
Selecting this item allows one or more files to be downloaded without having to manually select the destination. (The content of the files being downloaded automatically directs the file to the correct destination.) For technical reasons, Auto Select cannot be used to download Monitor, Power Micro, or Partition Table. These items must be specifically selected.
If the platform or application partition sizes are changed, you must download a new partition table first.
14-15
Page 534
14-16
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
5. IPL displays the Select Transport menu which lists the available methods of downloading the file. Select Transport Wireless S24 XX Serial Previous Top
Figure 14-8. Select Transport Menu If the mobile computer does not have a radio, then the WirelessS24XX selection is not available on the Transport menu.
6. Use the up and down scroll buttons to select the method of transport, then press Enter.
Page 535
Configuring the Mobile Computer
7. If you selected the Serial transport method, the Baud Rate Menu appears. Baud Rate Menu 115200 57600 38400 19200 9600 Previous Top
Figure 14-9. Baud Rate Menu 8. Use the up and down scroll buttons to select the appropriate baud rate, then press Enter.
14-17
Page 536
14-18
MC9000-K/S with Windows® Mobile 2003 Software for Pocket PCs PRGe
9. If you selected the Wireless S24XX transport method, the Address Configuration menu appears. Address Configuration
(DHCP) EShell MXIP (DHCP) Previous Top
Figure 14-10. Address Configuration Menu For wireless downloads, the ESSID partition must be loaded with the correct ESSID.
10. Use the up and down scroll buttons to select DHCP, then press Enter.