Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 29

Cyclone M2000 Series Product Reference Guide, pages 31 to 40

Pages 31 to 40 of 287

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol M2004, Symbol M2005 and Symbol M2007

Page 31

Scanning

Macro PDF Table 2-2 provides beeper definitions for Macro PDF mode. See Macro PDF Features on page 3-116 for an explanation of Macro PDF. Table 2-2. Macro PDF Beeper Indications Beeper Sequence

Indication

Error Long low tone

Hi-level decode error caused by incorrect symbol.

2 long low tones

File ID error. A bar code not in the current MPDF sequence was scanned.

3 long low tones

Out of memory. There is not enough buffer space to store the current MPDF symbol.

4 long low tones

Bad symbology. You scanned a 1-D or 2-D bar code in an MPDF sequence, a duplicate MPDF label, an incorrect sequence, or are trying to transmit an empty or illegal MPDF field.

5 long low tones

Flushing buffer.

Fast warble tone

Successful parameter scanned.

Decode Beep Sequence Short tone

Standard decode and transmit beep for all symbols.

Short low tone

1D portion of composite code was decoded. Decode beep follows when entire composite code is decoded.

Short high tone

2D portion of composite code was decoded. Decode beep follows when entire composite code is decoded.

Double short tone

MPDF symbol is buffered. A single beep indicates transmission of the buffered data.

2-7

Page 32

CycloneTM M2000 Series Product Reference Guide

LED Indications The lit LED indicates the selected scan pattern for hand-held and counter-top mode. In handheld mode, pressing the Scan Pattern Mode Selector button selects the next pattern, and lights the corresponding LED. (The counter-top laser pattern is selectable only via programming bar code.) When a bar code is successfully decoded, all three LEDs light momentarily. Raster Pattern Indicator Omni Pattern Indicator

Slab Pattern Indicator Scan Pattern Mode Selector

Figure 2-6. Laser Pattern Indicators

Maintenance The M2000 scanner is designed to provide reliable service over an extended period of time. The only maintenance required is cleaning the exit window. !

Do not allow any abrasive material to touch the window.

!

Remove any dirt particles with a damp cloth.

!

Wipe the window using a tissue moistened with ammonia/water.

!

Do not spray water or other cleaning liquids directly into the window.

2-8

Page 33

Scanning

Troubleshooting Table 2-3. Troubleshooting Problem

Possible Solution

Nothing happens when you follow the operating instructions.

Check the system power. Make sure you are using the correct interface cable for the host device. Check for loose cable connections. Make sure the scanner is programmed to read the symbology you are trying to read. See Chapter 3, Parameter Menus. Check the label to make sure it is not defaced; if damaged beyond its error correction capability, it will not decode. Try scanning a test symbol of the symbology you are trying to read.

Your scanner operates but scanned data is not displayed correctly.

Check the system power. Check for loose cable connections. Check that the communication parameters (baud rate, parity, stop bits, etc.) are set properly for the host device. If you’re working with a Synapse cable, refer to your Interface Guide.

The laser does not activate, which is You may be scanning in an inappropriately hot environment. followed by a beep sequence. Remove the scanner from the environment, or allow the laser to cool down. Transmitting PDF bar code data The scanner / wand emulation Synapse cable has a transmission through a scanner/wand emulation limit of approximately 46 characters. This does not apply to Synapse cable causes transmit other Synapse cables. errors. For the M2007 (USB), no data transmits, or incorrect data transmits, or a low/low/low/low tone sounds.

Check cable connection to scanner and host. Make sure the correct device options and country code parameters are set for the currently attached scanner. Increase Intercharacter Delay.

USB parameters are not working.

Make sure you’ve selected the correct parameter set. If you scanned a Set Defaults bar code, re-enter your parameters.

2-9

Page 34

CycloneTM M2000 Series Product Reference Guide

2-10

Page 35

Chapter 3 Parameter Menus Introduction The M2000 Series Scanner can be programmed to perform various functions, or activate different features. This chapter describes each feature and provides the programming bar codes necessary for selecting these features for your scanner. Before programming, follow the setup instructions in Chapter 1, Setting Up Your Scanner. The M2000 Series Scanner is shipped with the default settings shown in Table 3-1 on page 32. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change the default values by scanning single bar codes or short bar code sequences in this chapter. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the Set All Defaults bar code on page 3-10.

Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter. For example, if you want to set the baud rate to 9600, simply scan the 9600 bar code listed under Baud Rate on page 3-93. The scanner issues a warble tone, signifying a successful parameter entry. If you want to set specific code lengths or specify Serial Response Time-Out, you have to scan several bar codes. This procedure is described later in this chapter.

Errors While Scanning If you make an error during a scanning sequence, just rescan the correct parameter.

3-1

Page 36

CycloneTM M2000 Series Product Reference Guide

Default Table Table 3-1 lists the defaults for all parameters, and the page number each parameter appears on. If you wish to change any option, scan the appropriate bar code(s). Table 3-1. Default Table Parameter

Default

Page #

Set Default Parameter

All Defaults

3-10

Host Type

See page 3-11

3-11

Smart Raster

3-15

Hand-Held Scan Pattern Mode Selector

Enable

3-16

Counter-top Scan Pattern Mode

Cyclone

3-17

Raster Height

15

3-18

Raster Expansion Rate

11

3-18

Aiming Mode

Slab Raster

3-19

Trigger Mode

Level

3-20

Time-out Between Same Symbol

0.6 sec

3-21

Time-out Between Different Symbols

0.0 sec

3-21

Laser On Time

5.0 sec

3-22

30 Minutes

3-22

Enable

3-23

Beeper Volume

High Volume

3-23

Beeper Tone

High Frequency

3-24

Disable

3-24

Scanning Options Hand-Held Scan Pattern Mode

Time Delay to Low Power Mode Beep After Good Decode

Transmit “No Decode” Message

3-2

Page 37

Parameter Menus

Table 3-1. Default Table (continued) Parameter Linear Code Type Security Levels: Hand Held Counter-top

Default

Page # 3-25

2 1

Bi-directional Redundancy

Disable

3-27

Autodiscriminate Response Time

1.0 second

3-27

Composite Codes CC-C

Disable

3-28

Composite Codes CC-A/B

Disable

3-29

UPC-A

Enable

3-30

UPC-E

Enable

3-30

UPC-E1

Disable

3-31

EAN-8

Enable

3-31

EAN-13

Enable

3-32

Bookland EAN

Disable

3-32

UPC/EAN Coupon Code

Disable

3-33

Decode UPC/EAN Supplementals

Ignore

3-33

12

3-35

Transmit UPC-A Check Digit

Enable

3-35

Transmit UPC-E Check Digit

Enable

3-36

Transmit UPC-E1 Check Digit

Enable

3-36

UPC-A Preamble

System Character

3-37

UPC-E Preamble

System Character

3-38

UPC/EAN

Decode UPC/EAN Supplemental Redundancy

3-3

Page 38

CycloneTM M2000 Series Product Reference Guide

Table 3-1. Default Table (continued) Parameter

Default

Page #

UPC-E1 Preamble

System Character

3-39

Convert UPC-E to A

Disable

3-40

Convert UPC-E1 to A

Disable

3-41

EAN-8 Zero Extend

Disable

3-42

EAN Zero Extend Type

Type is EAN-13

3-42

UPC/EAN Security Level

0

3-43

Linear UPC/EAN Decode

Disable

3-45

UPC Half Block Stitching

Enable

3-45

Linked 1D Send Mode

Disable

3-46

UPC Composite Mode

Always Linked

3-47

Code 128

Enable

3-48

UCC/EAN-128

Enable

3-48

ISBT 128

Disable

3-49

Code 128 Decode Performance

Enable

3-50

Code 128 Decode Performance Level

Level 1

3-51

Code 39

Enable

3-52

Trioptic Code 39

Disable

3-52

Convert Code 39 to Code 32

Disable

3-53

Code 32 Prefix

Enable

3-54

Code 128

Code 39

3-4

Page 39

Parameter Menus

Table 3-1. Default Table (continued) Parameter

Default

Page #

Length within Range: 01-55

3-55

Code 39 Check Digit Verification

Disable

3-57

Transmit Code 39 Check Digit

Disable

3-57

Code 39 Full ASCII Conversion

Disable

3-58

Code 39 Decode Performance

Enable

3-59

Code 39 Decode Performance Level

Level 1

3-60

Disable

3-61

Length within Range: 04-55

3-62

Disable

3-64

1 Discrete Length: 14

3-65

I 2 of 5 Check Digit Verification

Disable

3-67

Transmit I 2 of 5 Check Digit

Disable

3-68

Convert I 2 of 5 to EAN 13

Disable

3-69

Disable

3-70

1 Discrete Length: 12

3-71

Disable

3-73

Set Length(s) for Code 39

Code 93 Code 93 Set Length(s) for Code 93

Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5

Discrete 2 of 5 Discrete 2 of 5 Set Length(s) for D 2 of 5 Codabar Codabar

3-5

Page 40

CycloneTM M2000 Series Product Reference Guide

Table 3-1. Default Table (continued) Parameter

Default

Page #

Length within Range: 05-55

3-74

CLSI Editing

Disable

3-76

NOTIS Editing

Disable

3-76

Disable

3-77

Length Within Range: 06 - 55

3-78

One

3-80

Transmit MSI Plessey Check Digit

Disable

3-80

MSI Plessey Check Digit Algorithm

Mod 10/Mod 10

3-81

PDF417

Enable

3-82

MicroPDF417

Disable

3-82

MicroPDF Performance

Standard

3-83

Code 128 Emulation

Enable

3-84

RSS-14

Disable

3-85

RSS-Limited

Disable

3-85

RSS-Expanded

Disable

3-86

None

3-87

Set Lengths for Codabar

MSI Plessey MSI Plessey Set Length(s) for MSI Plessey

MSI Plessey Check Digits

PDF417/MicroPDF417

RSS Codes

Data Options Transmit Code ID Character

3-6