Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 29

Cyclone M2000 Series Product Reference Guide, pages 21 to 30

Pages 21 to 30 of 287

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol M2004, Symbol M2005 and Symbol M2007

Page 21

Setting Up Your Scanner

Switching Cables Different cables are required for different hosts. To change the scanner cable: 1. Unplug the installed cable’s modular connector by depressing the connector clip through the access hole on the bottom of the scanner with a screwdriver or paper clip.

Access Hole

Figure 1-2. Bottom of M2000 Scanner 2. Carefully slide out the cable. 3. Follow the previous steps to connect a new cable.

Caution Be sure you are using the correct cable for your host. Using a cable incompatible with the host may cause damage to your scanner or host.

Wall Mounting the Scanner An optional wall-mount bracket is available for using the M2000 in presentation applications. To wall-mount the M2000: 1. Place the bracket in its desired location on the wall, and place a pencil mark on the wall through each keyhole in the bracket. 2. Remove the bracket, and insert the screws provided into the pencil marks on wall. Do not tighten them all the way; leave enough space for the bracket’s keyholes to slide onto.

1-5

Page 22

CycloneTM M2000 Series Product Reference Guide

3. Insert the bracket’s keyholes over the screws, and slide the bracket down to secure. If necessary, tighten the screws.

Figure 1-3. Installing the Wall Mount Bracket 4. Slide the base of the scanner into the bracket, oriented so the scan window faces down.

Accessories Required Accessories These items must be included to complete the system, and are available through contacting your local Symbol representative or business partner. !

Host interface cables for RS-232 operation (available in 6-foot and 8.5-foot lengths.) " 25-Pin Male D Connector (TxD on Pin 3) " 25-Pin Male D Connector (TxD on Pin 2) " 25-Pin Female D Connector (TxD on Pin 3) " 25-Pin Female D Connector (TxD on Pin 2) " 9-Pin Female D Connector (PC AT: TxD on Pin 3)

!

16-foot Synapse cable

!

Synapse adapter cable

!

Power supply (select one): " 115 VAC Power Supply " 220/240 VAC Power Supply (Europe)

1-6

Page 23

Setting Up Your Scanner

" 100 VAC Power Supply (Japan) !

User documentation (CycloneTM M2000 Series Product Reference Guide).

Optional Accessories An optional Wall Mount Bracket is not included in the standard configuration, and is available through contacting your local Symbol representative or business partner.

Electronic Article Surveillance (EAS) (Optional) Because there are several Checkpoint EAS systems available, your local Checkpoint representative should install the EAS cable. To contact your local Checkpoint representative inside the U.S. call 800-257-5540, ext. 4300. Outside the U.S., call (609) 848-1800, ext. 4300. If you are using an EAS cable, refer to the Universal Cable EAS Installation Sheet (Symbol p/n 70-32824-xx).

1-7

Page 24

CycloneTM M2000 Series Product Reference Guide

1-8

Page 25

Chapter 2 Scanning Introduction This chapter describes the various laser patterns and scanning modes available in the M2000 scanner, provides instructions and tips for scanning, and lists beeper and LED indications.

Scanning Modes The M2000 may be used on the counter-top or in a hand-held orientation. In hand-held use, the scanner operates in triggered mode where you pull the trigger to activate the scan pattern and decode the bar code. In counter-top use, the scanner operates in continuous (constanton) mode, where it automatically decodes a bar code presented in its field of view.

Laser Patterns The scanner emits one of four laser patterns: !

Cyclone Omnidirectional Pattern is a highly efficient scan pattern which decodes 1D and EAN/UCC reduced space symbologies in any orientation.

!

Cyclone Semi-omnidirectional Pattern, an alternative to the full omnidirectional pattern, scans highly truncated bar codes. The bar code must be presented horizontally with up to 20o tilt.

2-1

Page 26

CycloneTM M2000 Series Product Reference Guide

!

Raster Laser Pattern directly opens the laser to a raster pattern for scanning 1D, PDF417, RSS, and composite codes.

!

Slab Laser Pattern creates a slab raster pattern (optimal for 1D, small PDF417, and RSS codes) which opens vertically for PDF417 symbols using the Smart Raster feature. This feature autodetects the type of bar code being scanned and adjusts its pattern accordingly. This provides optimal performance on 1D, PDF417, EAN/UCC, RSS and composite codes.

One pattern can be selected for counter-top mode and another for hand-held mode via programming bar code in Chapter 3, Parameter Menus. For hand-held mode, you may alternatively select a pattern by pressing the Scan Pattern Mode Selector button when the scanner is lifted off the counter. Raster Pattern Indicator

Omni Pattern Indicator

Single-Scan Line Indicator

Scan Pattern Mode Selector

Figure 2-1. Top of M2000 Scanner To scan in hand-held mode, pick up the scanner and hold it within the scanning range for the bar code. A sensor on the bottom of the scanner’s stand detects when the scanner is lifted off the counter, and automatically switches to the programmed hand-held laser pattern.

2-2

Page 27

Scanning

Smart Raster In Smart Raster operation, a trigger pull causes a slab raster pattern to appear. If the target is a 1-D bar code, the scanner decodes the symbol. If the target bar code is a 2-D bar code, the scanning patterns open up to a full, optimized raster pattern as soon as the scanner is properly aligned over the bar code. “Slab” Raster Pattern

Y-Axis

Y-Axis

Open Raster Pattern

Horizontal Displacement (X - Axis)

Figure 2-2. M2000 Scanning Patterns

Scanning 1D or 2D Bar Codes When scanning a bar code: !

Keep the scan pattern parallel to the symbol’s rows.

!

Hold the scanner as still as possible.

!

Hold the scanner at an angle which does not cause specular reflection (see Specular Reflection on page 2-5).

!

Hold the scanner close for dense symbols, and farther away for large symbols. Practice shows what works.

2-3

Page 28

CycloneTM M2000 Series Product Reference Guide

!

When using the raster pattern, if the pattern does not cover the top and bottom of a 2D symbol, pull the scanner back until it does. Make sure the scan pattern extends at least three quarters of an inch beyond the edges of the bar code.

3/4”

3/4”

Figure 2-3. Raster Pattern Expanded Over PDF417 Symbol !

If the vertical scan pattern is not high enough to cover a “tall” PDF417 symbol, move the scanner slowly down toward the bottom of the symbol, keeping the beam horizontal to the rows, and then slowly back upward to the top.

Figure 2-4. Moving Scan Pattern Upward and Downward on “Tall” PDF Symbol !

The scan beam does not have to be perfectly parallel with the top and bottom of the symbol (up to a 4o tilt is permitted).

!

Be sure the symbol is in good condition.

The scanner emits a short, high-tone beep and lights the three green LEDs to indicate a successful decode. Decoded data is transmitted to the host device. Be sure that the RS-232C or IBM 4683 parameters (e.g., baud rate, parity) are set properly. Communication parameters are described in Chapter 3, Parameter Menus.

2-4

Page 29

Scanning

Specular Reflection When laser beams reflect directly back into the scanner from the bar code, they can “blind” the scanner and make decoding difficult. This is specular reflection. To avoid this, scan the bar code so that the beam does not bounce directly back. But don’t scan at too oblique an angle; the scanner needs to collect scattered reflections from the scan to make a successful decode. Practice quickly shows what tolerances to work within.

Tilt Back At Slight Angle (Up to 30°)

Specular reflection: reflected beam interferes.

Bar Code

30o

No specular reflection. Decode can occur.

Bar Code

Figure 2-5. Avoiding Specular Reflection When scanning a 1D bar code, there is only a small specular dead zone to avoid (+ 2o from the direct laser beam). The specular dead zone is larger for scanning PDF417 (+ 9o from the direct laser beam). However, the scanner is not effective if its beams hit the bar code’s surface at an angle greater than 30o from the normal to that surface.

2-5

Page 30

CycloneTM M2000 Series Product Reference Guide

Beeper Definitions Table 2-1 provides standard beeper definitions. Table 2-1. Standard Beeper Definitions Beeper Sequence

Indication

Standard Use Short high tone

A non-composite bar code symbol was decoded (if decode beeper is enabled).

3 short high tones

Power-on or reset. Occurs immediately after the scanner is turned on, indicating that the system software is working properly. If three beeps occur during normal operation, it is due to a reset and any work in progress is lost. If this occurs often, contact the Symbol Services Division.

Parameter Menu Scanning 2 short high tones

Correct entry scanned or correct menu sequence performed.

High/low tone

Keyboard parameter selected. Enter value using numeric bar codes.

High/low/high/low tone

Successful program exit with change in the parameter setting.

Low/high tone

Input error, incorrect bar code, or “Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.

Communication 4 short low tones

Communication error.

High/high/high/low tone Receive error. Low/high/low tone

2-6

ADF transmit error.