Page 41

Parameter Menus

Table 3-1. Default Table (continued) Parameter Prefix/Suffix Values Prefix Suffix Scan Data Transmission Format

Default

Page # 3-89

Enter Enter Data as is

3-90

Slab/Raster: Enable Omni: Disable

3-92

Baud Rate

9600

3-93

Parity

None

3-95

Check Parity

Enable

3-97

Hardware Handshaking

None

3-98

Software Handshaking

None

3-101

Stop Bit Select

1

3-103

Intercharacter Delay

0

3-103

2 sec

3-104

Host Serial RTS Line State

Low RTS

3-104

Beep on <BEL>

Disable

3-105

Data Transmission Format

8-bit

3-105

Set USB Defaults

--

3-106

USB Device Type

IBM Hand-Held USB

3-107

Country Selection

North American, Standard

3-109

Decode Buffering

RS-232 Options

Host Serial Response Time-out

USB (M2007 only)

3-7

Page 42

CycloneTM M2000 Series Product Reference Guide

Table 3-1. Default Table (continued) Parameter

Default

Page #

No Delay (0 ms)

3-113

Disable

3-114

Send Bar Codes with Unknown Characters

3-115

Buffer All Symbols/ Transmit Macro PDF when Complete

3-117

Transmit Each Symbol in Codeword Format

Disable

3-119

Transmit Unknown Codewords

Disable

3-120

Escape Character

None

3-121

Delete Character Set ECIs

Enable

3-122

ECI Decoder

Enable

3-123

Transmit File Name

Disable

3-124

Transmit Block Count

Disable

3-125

Transmit Time Stamp

Disable

3-125

Transmit Sender

Disable

3-126

Transmit Addressee

Disable

3-126

Transmit Checksum

Disable

3-127

Transmit File Size

Disable

3-127

Transmit Macro PDF Control Header

Disable

3-128

Keystroke Delay CAPS LOCK Ignore Unknown Characters

Macro PDF Macro PDF Transmit/Decode Mode

ECI

Transmit Macro PDF User-Selected Field

3-8

Page 43

Parameter Menus

Table 3-1. Default Table (continued) Parameter

Default

Page #

Last Block Marker

Disable

3-128

Flush Macro Buffer

N/A

3-129

Abort Macro PDF Entry

N/A

3-129

3-9

Page 44

CycloneTM M2000 Series Product Reference Guide

Set Default Parameter Scanning this bar code returns all parameters to the values listed in Table 3-1 on page 3-2.

Set All Defaults

3-10

Page 45

Parameter Menus

Host Type If you’re using a Synapse cable, your host is autodetected, so you don’t have to scan a host bar code. If not, select an IBM 46XX or RS-232 host from the following bar code menus.

IBM 46XX Host Types To select one of the following as a POS Interface, scan the appropriate bar code below. Note: To properly communicate with 468X/9X terminals, the driver corresponding to the port being used must be loaded and enabled when you are configuring your terminal system. See your terminal’s operating manual for details.

Port 5B

Port 9B

Port 17/9E

3-11

Page 46

CycloneTM M2000 Series Product Reference Guide

RS-232C Host Types Three RS-232C hosts are set up with their own parameter default settings (Table 3-2). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still apply. Table 3-2. Terminal Specific RS-232C Parameter

ICL

Fujitsu

Nixdorf Mode A/Mode B

Yes

Yes

Yes

Data Transmission Format

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR (1013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

Parity

Even

None

Odd

Hardware Handshaking

RTS/CTS Option 3

None

RTS/CTS Option 3

Software Handshaking

None

None

None

Serial Response Time-out

9.9 Sec.

2 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

Beep On <BEL>

Disabled

Disabled

Disabled

RTS Line State

High

Low

*Low = No data to send

Transmit Code ID

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.

3-12

Page 47

Parameter Menus

RS-232C Host Types (continued) Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID characters as listed in Table 3-3. These Code ID characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals. Note: These Code IDs do not apply when Standard RS-232C is selected. Table 3-3. Terminal-Specific Code ID Characters Code Type

ICL

Fujitsu

Nixdorf

UPC-A

A

A

A0

UPC-E

E

E

C0

EAN-8

FF

FF

B

EAN-13

F

F

A

Code 39

C <len>

None

M

Codabar

N <len>

None

N

Code 128

L <len>

None

K

I 2 of 5

I <len>

None

I

UCC/EAN 128

L <len>

None

P

Bookland EAN

F

F

A

3-13

Page 48

CycloneTM M2000 Series Product Reference Guide

RS-232C Host Types (continued) To select an RS-232C host interface, scan one of the following bar codes.

ICL RS-232C

Standard RS-232C

OPOS

Nixdorf RS-232C Mode B

Nixdorf RS-232C Mode A

Fujitsu RS-232C

3-14

Page 49

Parameter Menus

Scanning Options Hand-Held Scan Pattern Mode Select one of the following scan pattern options to use when the scanner is in hand-held use (see Scanning Modes on page 2-1 for descriptions):

Smart Raster

Always Raster

Programmable Raster

Slab Pattern

Omnidirectional Cyclone Pattern

Semi-omni Pattern

3-15

Page 50

CycloneTM M2000 Series Product Reference Guide

Scan Pattern Mode Selector Select whether the user can select the hand-held laser pattern via the Scan Pattern Mode Selector button.

Enable Mode Selector Button

Disable Mode Selector Button

3-16