Page 31
LT 1820 Product Reference Guide: Programming the LT 1820
NOTIS Editing This option strips the start and stop characters from decoded Codabar symbols.
Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters, or whether the unit will autodiscriminate between the two. Supplementals are additionally appended characters, according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+5). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/ EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LT 1820 will, after additional processing to ensure a good decode, transmit either.
Beep After Good Decode Determine if the unit beeper will sound during normal scanning. Usually it is desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. See Beeper Definitions on page 4-14.
Beeper Volume Use this parameter to program the beeper for Full or Low volume.
Trigger Mode (for triggered models only) Select whether you would like to use the scanner with the trigger (Triggered Mode) for low power consumption, or if you’d like the laser to be in a constant blinking state (Triggerless Mode) using continuous power. The Triggered Mode has been designed for battery operation and is recommended for use with portable terminals.
4-6
Page 32
LT 1820 Product Reference Guide: Programming the LT 1820
Decode Redundancy Use this parameter to indicate whether the scanner must read a bar code one time (LEVEL 0), two times (LEVEL 1), or three times (LEVEL 2) before decoding it. A higher level of redundancy ensures the accuracy of a decode in, for example, poor quality symbols.
Scan and Store (Code 39 Buffering) When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See Code 39 Buffering (Scan and Store) beginning on page 4-16 for further details. When the scan and transmit option is selected, decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer. Scan and Store affects Code 39 decodes only. If you select scan and store, it is recommended that you configure the scanner to decode Code 39 symbology only.
Baud Rate Baud rate is the number of bits of data transmitted per second. The unit's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.
Parity A parity check bit is the most significant bit of each ASCII coded character. If you select ODD parity, the parity bit will have a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
4-7
Page 33
LT 1820 Product Reference Guide: Programming the LT 1820
If you select EVEN parity, the parity bit will have a value, 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. Select MARK parity and the parity bit will always be 1. Select SPACE parity and the parity bit will always be 0. Select the parity type according to host device requirements.
Hardware Handshaking Hardware handshaking allows you to check the readiness of the receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is needed to prevent loss of transmitted data. Select whether the scan data is to be transmitted as soon as it is available or whether transmission follows the RTS/CTS procedure. See Communication Protocols on page 4-18 for more details.
Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. These options may be combined, for example ACK/NAK with ENQ. 1. No Software Handshaking 2. ACK/NAK Only The ACK/NAK option checks the success or failure of transmission. The scanner expects one of the following host responses after a data transmission: <ACK> - Acknowledges a valid and successful transmission. <NAK> - Indicates a problem with the transmission. Whenever a <NAK> is received, the unit retransmits the same data and awaits an ACK/NAK response. After three unsuccessful attempts to transmit the same data, the scanner aborts any further communication attempts on that message. Transmission error is indicated by the unit sounding 4 long beeps.
4-8
Page 34
LT 1820 Product Reference Guide: Programming the LT 1820
3. ENQ ONLY The ENQ option needs the host to request data before it is transmitted to the host. This ensures that data transmission occurs only when the host is ready to receive. When you select the wait for ENQ option, the scanner waits for an ENQ, Enquire, character from the host before it transmits data; otherwise, the unit transmits data without waiting for an ENQ character from the host. With ENQ enabled, the scanner must receive an ENQ from the host within a 2 second period after the last activity or 4 long beeps are sounded to indicate a transmission error; the unit is now ready to scan again. 4. ACK/NAK with ENQ This combines both handshaking options.
Xmit “No Decode” Character This feature gives you the option to transmit “NR” when a symbol does not decode. Prefixes and suffixes enabled will be appended around this character. Note: This option is available in Triggered Mode only.
Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
Prefix The scanner will add one of the following start-of-text characters to transmitted data. • • •
None Start-of-text <STX> One user-defined prefix (can be any ASCII character).
4-9
Page 35
LT 1820 Product Reference Guide: Programming the LT 1820
Suffix Select one or two end-of-text characters to be added to transmitted data: • None • CR (Carriage Return) - Returns the cursor to the same position on the line after each decode. • LF (Line Feed) - Moves the cursor down a line after each decode. • CR & LF - Allow you to select where the cursor on a display terminal returns to after it displays each decoded symbol. Selecting both CR & LF, returns the cursor to the same position on successive lines after each decode. If you select no control code, the cursor remains where it stopped after the last transmission. • End-of-text <ETX>. • One or two characters, user-defined.
Communications Delays and Timeouts (Intercharacter Delay) Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 ms delay between the transmission of each character.
UPC A and E Preamble(s) Three options are given for the lead-in characters of decoded UPC-A or UPCE symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble
The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.
4-10
Page 36
LT 1820 Product Reference Guide: Programming the LT 1820
Data Format This parameter sets the transmit data format. The options are 7 Data Bits (with Parity), 8 Data Bits (with Parity), and 8 Data Bits (without Parity). The PARITY parameter applies only to the 7 Data Bits (with Parity), and 8 Data Bits (with Parity) options. The default is 7 Data Bits (with Parity).
4-11
Page 37
LT 1820 Product Reference Guide: Programming the LT 1820
Parameter Selections PARAMETER
SELECTIONS AVAILABLE
DEFAULT
Add Code Types to be Decoded
Code 39, Code 39 Full ASCII, Discrete 2 of 5, Interleaved 2 of 5, Codabar, UPC/EAN, Code 93, Code 128, All Code Types
All Code Types
First Length Discrete 2 of 5
2 digit entry, ranging from 01-31.
12
Second Length Discrete 2 of 5
2 digit entry, ranging from 00-31.
0
First Length Interleaved 2 of 5
2 digit entry, ranging from 01-31.
14
Second Length Interleaved 2 of 5
2 digit entry, ranging from 00-31.
0
Xmit UPC-A Check Digit
Enable, Disable
Enable
Xmit UPC-E Check Digit
Enable, Disable
Enable
Decode UPC Only
Enable, Disable
Disable
Convert UPC-E to A
Enable, Disable
Disable
Xmit Code ID Character
Enable, Disable
Disable
EAN Zero Extend
Enable, Disable
Disable
CLSI Editing
Enable, Disable
Disable
NOTIS Editing
Enable, Disable
Disable
UPC/EAN Supplemental
No Supplemental, Supplemental Only, Autodiscriminate
No Supplemental
Beep After Good Decode
Enable, Disable
Enable
Beeper Volume
Low, Full
Full
Trigger Mode (triggered models only)
Triggered, Triggerless
Triggered
Decode Redundancy
Level 0, Level 1, Level 2
Level 0
Buffer Code 39 Symbols (Scan and Store)
Enable, Disable
Disable
Baud Rate
300, 600, 1200, 2400, 4800, 9600, 19,200
9600
Parity
Even, Odd, Mark, Space
Even
4-12
Page 38
LT 1820 Product Reference Guide: Programming the LT 1820
PARAMETER
SELECTIONS AVAILABLE
DEFAULT
Hardware Handshaking
None, RTS/CTS
None
Software Handshaking
None, ENQ, ACK/NAK, ACK/NAK with ENQ
None
Stop Bit Select
One, Two
Two
Xmit “No Decode” Character
“NR”, No Character
No Character
Prefix to Decoded Data
None, Start-of-text <STX>, User's Choice (1 selection)
None
Suffix to Decoded Data
None, CR, LF, CR/LF, User's CR/LF Choice (1 selection), User's Choice (2 selections), End-of-text <ETX>
Intercharacter Delay
00-99 ms
None
UPC-E Preamble
System Character, System Character & Country Code, None
System Character
UPC-A Preamble
System Character, System Character & Country Code, None
System Character
Data Format
7 Data Bits (with Parity), 8 Data Bits (with Parity), 8 Data Bits (without Parity)
7 Data Bits (with Parity)
4-13
Page 39
LT 1820 Product Reference Guide: Programming the LT 1820
Beeper Definitions Standard Use BEEPER SEQUENCE
INDICATION
1 Beep - short high tone
A symbol has been successfully decoded.
4 Beeps - long low tone
Error in transmission; loss of last data scanned. Scan last data again.
4 Beeps - short high tone
Power Supply: Insufficient power condition. Battery Pack: Low voltage indicated. No further scanning is possible. Change or recharge battery.
Parameter Menu Scanning BEEPER SEQUENCE
INDICATION
1 Beep - short high tone
Appropriate menu within the scanning sequence has been read.
1 Beep - warble sound
Parameter value has been entered successfully.
2 Beeps - long low tone
Parameter not entered or incorrect sequence performed. Scan CANCEL and restart the scanning sequence.
4-14
Page 40
LT 1820 Product Reference Guide: Programming the LT 1820
Code 39 Scan and Store BEEPER SEQUENCE
INDICATION
1 Beep - hi/low tone
Indicates new data being entered into the buffer.
1 Beep - short lo/hi/lo tone
The buffer has been erased, or there was an attempt to transmit an empty buffer. When the buffer was empty, the LT 1820 read a command to clear or to transmit a Code 39 buffer.
3 Beeps - long high tone
Code 39 buffer is full.
4 Beeps - long low tone
Error in transmitting stored buffer data.
1 Beep - lo/hi tone
Transmission of stored buffer data is good.
4-15