LT 1820 Product Reference Guide: Maintenance and Specifications
LT 1820 Signal Descriptions The following signal descriptions apply to the connection between the scanner and the cable, and are for reference only. PIN
SIGNAL NAME
FUNCTION
1
DTR
Data Terminal Ready. This signal is hardwired active.
2
VBATT
Input power.
3
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
4
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
5
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be utilized in conjunction with the CTS line.
8
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
10
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
PIN 10
PIN 1
3-6
Page 22
LT 1820 Product Reference Guide: Maintenance and Specifications
Interface Cable Pinouts 25-Pin, Male, D-Type Connector; 25-06753-01 for power supply version 20-03113-01 for battery pack version PIN
SIGNAL NAME
FUNCTION
2
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
5
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be utilized in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
3-7
Page 23
LT 1820 Product Reference Guide: Maintenance and Specifications
25-Pin, Male, D-Type Connector; 25-06862-01 for power supply version 20-03114-01 for battery pack version PIN
SIGNAL NAME
FUNCTION
2
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.
5
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
7
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is hardwired active.
3-8
Page 24
LT 1820 Product Reference Guide: Maintenance and Specifications
25-Pin, Female, D-Type Connector; 25-06860-01 for power supply version 20-03115-01 for battery pack version PIN
SIGNAL NAME
FUNCTION
2
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
5
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be utilized in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
3-9
Page 25
LT 1820 Product Reference Guide: Maintenance and Specifications
25-Pin, Female, D-Type Connector; 25-06858-01 for power supply version 20-03116-01 for battery pack version PIN
SIGNAL NAME
FUNCTION
2
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be utilized in conjunction with the CTS line.
5
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
7
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is hardwired active.
3-10
Page 26
Chapter 4 Programming the LT 1820 Before programming the scanner, follow the instructions in Chapter 1: Setting Up the LT 1820. If the default values suit your requirements, all you need to do is scan the SET DEFAULT bar code. An LT 1820 is programmed for parameters other than default values by scanning sequences of bar codes. Chapter 5: Parameter Menus contain all the bar codes necessary to program the scanner for each parameter selection.
Scanning Sequences A scanning sequence establishes a value for one parameter type. During a scanning sequence, you scan bar codes for a parameter type, a parameter value, and ENTER. The Scanning Sequence Flowchart on page 4-3 illustrates this process. Chapter 5: Parameter Menus contains all the bar codes needed to program the scanner.
Scanning Sequence Examples Suppose you want to program the scanner for all default settings except for two parameters, DECODE UPC ONLY and INTERCHARACTER DELAY. Since you want to keep most of the default settings, scan the SET DEFAULT bar code. The default for DECODE UPC ONLY is DISABLED - you need it ENABLED. Scan the three bar codes in the order listed below: SCAN 1. DECODE UPC ONLY
YOU WILL HEAR . . . Short high tone
2. ENABLED
Short high tone
3. ENTER
Hi/Lo/Hi/Lo warble 4-1
Page 27
LT 1820 Product Reference Guide: Programming the LT 1820
After the last scan in a successful scanning sequence (ENTER), the warble sound (i.e., hi/lo/hi/lo) indicates that the scanner has been successfully programmed for the selected parameter. For other beeper indications, see Beeper Definitions on page 4-14. The INTERCHARACTER DELAY default is 00 ms; in this example you want to set it to 2 ms. To program the scanner for a 2 ms INTERCHARACTER DELAY, scan the four bar codes listed below. There are four bar codes because this sequence includes a two digit entry; note that single digit entries must have a leading zero. SCAN
YOU WILL HEAR . . .
1. INTERCHARACTER DELAY
Short high tone
2. 0
Short high tone
3. 2
Short high tone
4. ENTER
Hi/Lo/Hi/Lo warble
Errors While Scanning Don’t worry if you make an error during a scanning sequence. There are two special-purpose bar codes, BACKSPACE and CANCEL, to help you. Scanning the BACKSPACE bar code erases the value of the previous bar code scanned but keeps you within the scanning sequence for a parameter type. Scanning CANCEL removes you from the current sequence so that you can start again.
4-2
Page 28
LT 1820 Product Reference Guide: Programming the LT 1820
Scanning Sequence Flowchart Re-Select
START
Re-Select
Incorrect parameter type
CANCEL
SELECT AND SCAN PARAMETER TYPE
GOOD
Re-Select
No Good CANCEL
SELECT AND SCAN (PARAMETER VALUE)
GOOD
SCAN ENTER (Parameter is Set)
4-3
No Good BACKSPACE
Page 29
LT 1820 Product Reference Guide: Programming the LT 1820
Parameter Descriptions See Parameter Selections on page 4-12 for the range of values and default settings for each parameter type.
Set Parameter Defaults Scanning the SET DEFAULT bar code returns all parameters to the default values listed in Parameter Selections on page 4-12.
Code Types The bar code menu selections enable the scanner to decode any or all of the following symbologies. • UPC Versions A and E (EAN 8 and 13)
• Codabar
• Code 39
• Discrete 2 of 5
• Interleaved 2 of 5
• Code 128
• Code 93
• Code 39 Full ASCII
The scanner will autodiscriminate between all of the above symbologies, except for Code 39 and Code 39 Full ASCII. If UPC/EAN with supplemental characters is selected, UPC/EAN without supplemental characters is ignored. See Decode UPC/EAN Supplemental on page 4-6 for details. If you want to add Discrete 2 of 5 or Interleaved 2 of 5, check the previously enabled lengths. To set lengths for these codes, see Fixed Lengths For Code 2 of 5 on page 5-5.
Fixed Lengths for Code 2 of 5 Select one or two lengths for the Interleaved or Discrete 2 of 5 codes. Determine the number of characters represented in each code type by counting the number of printed (i.e., human readable) digits that represent a bar code label. One length (Length 1) or two lengths (Length 2) for either code type may be set, as needed.
4-4
Page 30
LT 1820 Product Reference Guide: Programming the LT 1820
If any default setting is in effect and is an appropriate length, it need not be reset. Set one or both lengths, one per scanning sequence. LENGTH 1 may range from 01-31 and LENGTH 2 may range from 00-31.
Decode Options Transmit UPC-E/UPC-A Check Digit Select if decoded UPC-E or UPC-A symbols are transmitted with or without the check digit.
Decode UPC Only (Not EAN) If selected, this option limits LT 1820 UPC/EAN decode capability to UPC versions only. It disables EAN decode capability.
Convert UPC-E to UPC-A Use this parameter to convert UPC-E (zero suppressed) decoded data to UPCA format before transmission. After conversion, data will follow UPC format and be affected by UPC programming selections (e.g., Preamble, Check Digit).
Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single-character prefix already selected, the code ID character is appended as a prefix to the decode. Code ID characters are: A = UPC-A, UPC-E, EAN-13, or EAN-8; B = Code 39; C = Codabar; D = Code 128; E = Code 93; F = Interleaved 2 of 5; G = Discrete 2 of 5 or Discrete 2 of 5 IATA.
EAN Zero Extend This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
CLSI Editing Use this parameter to insert a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. The symbol length includes start and stop characters.
4-5