Page 11
LT 1820 Product Reference Guide: Setting Up the LT 1820
External Power Supply Operation • Make sure that the host device is powered down before you connect the scanner. • Plug the connector at the end of the scanner's straight cable into the appropriate RS-232C receiving port on your host device. • Plug one end of the power supply cable into the power supply port on the side of the LT 1820 connector. • Connect the power supply to an AC receptacle supplying voltage of the appropriate level.
1-4
Page 12
LT 1820 Product Reference Guide: Setting Up the LT 1820
Battery Operation • Insert a 9-volt battery into the battery pack. • Plug the 9-pin connector at the end of the scanner's coil cord into one end of the battery pack. • Use the adapter cable to connect the LT 1820 to the host device. Connect one end of this cable to the battery pack and the other to the appropriate port on the host device (either a stationary or portable terminal). • If desired, plug one end of the power supply connector into the receptacle on the side of the battery pack. Plug the other end of the connector into an AC outlet. Portable Operation: Using Scanner Holster, Battery Pack, and Terminal Holster
Front View: Belt Goes through Loop on Back of Holster, Battery Pack, and Portable Terminal Holster LT 1820
Back View Portable Terminal
Battery Box
Scanner Holster
12”Adapter Cable
5’ Coiled Scanner Cable
You can use either an alkaline battery, or a nickel-cadmium rechargeable battery, with an LT 1820 scanner. Low battery power is signaled by four short, high tone beeps, coupled with scanning interruptions. If this occurs, change or recharge the battery as soon as possible.
1-5
Page 13
LT 1820 Product Reference Guide: Setting Up the LT 1820
Changing the Battery • Disconnect the battery pack. • To open the battery pack, push up on the flanges at one end of the pack. • Remove the old battery. • Insert the new or recharged 9-volt battery into the battery pack. Match the positive (+) and negative (-) terminals on the battery with the corresponding terminals in the battery pack.
Recharging a Nickel-Cadmium Battery • Remove the battery from the battery pack and place it in the recharging unit. • To recharge the battery, follow the instructions supplied with the recharging unit.
1-6
Page 14
Chapter 2 Scanning with the LT 1820 Scanning • Make sure the scanner is connected to the controller or portable data terminal before you turn on the system. • Make sure the symbol you want to scan is within the LT 1820 scanning range. (See LT 1820 Decode Zone on page 2-2.) • If the scanner is in triggerless mode, simply bring the scanner to the bar code. The scan beam is in a constant blinking state which becomes steady when the scanner is decoding a bar code. • If the scanner is in triggered mode, bring the scanner to the bar code and press the trigger. The scan beam (and red LED on the top of the scanner) illuminates for approximately 1 second, or until a successful decode. • Your scan beam must cross every bar and space on the symbol. RIGHT
WRONG
012345
012345
• When the symbol has been decoded, you will hear a short, high-tone beep, and the green decode LED will light.
2-1
Page 15
LT 1820 Product Reference Guide: Scanning with the LT 1820
LT 1820 Decode Zone 3 in 7.62 cm 2.5 in 6.35 cm 2 in 5.08 cm 1.5 in 3.81 cm
.5 in 1.27 cm 0 in 0 cm .5 in 1.27 cm 1 in 2.54 cm 1.5 in 3.81 cm 5.5 mil (0"-.75")
2 in 5.08 cm
6 mil (0" - 1")
2.5 in 6.35 cm
7.5 mil (0" - 2.2")
3 in 7.62 cm
13 mil (0"-5") (100% UPC/EAN)
0 in
.5 in
1 in
1.5 in
2 in
2.5 in
3 in
3.5 in
4 in
4.5 in
5 in
0 cm
1.27 cm
2.54 cm
3.81 cm
5.08 cm
6.35 cm
7.62 cm
8.89 cm
10.16 cm
11.43 cm
12.70 cm
DISTANCE FROM SCANNER
2-2
WIDTH OF FIELD
SCANNER NOSE
1 in 2.54 cm
Page 16
Chapter 3 Maintenance and Specifications Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. • Do not allow any abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window. • Do not remove the nose of the scanner.
What If... Nothing happens when you follow the operating instructions. You Should • Check the system power; check the power supply or battery pack connections. • Make sure the controller is programmed to decode bar codes of the symbology you are scanning. • Check for loose cable connections. • Make sure the symbol is not defaced. • Try scanning test symbols of the same code type.
Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. See Symbol Support Center on page ii for the telephone number. 3-1
Page 17
LT 1820 Product Reference Guide: Maintenance and Specifications
Accessories Standard Accessories: Part Number 70-08043-0X 70-16223-0X 50-01400-184
Description LT 1820 Product Reference Guide LT 1810/1820 Quick Reference Guide Shipping Box
Power Supply Operation: RS-232C Single Port Straight Cables: Part Number 25-06862-01 25-06753-01 25-06858-01 25-06860-01
Connector Type Male, 25-Pin (TxD on pin 2) Male, 25-Pin (TxD on pin 3) Female, 25-Pin (TxD on pin 2) Female, 25-Pin (TxD on pin 3)
Power Supplies: Part Number 50-14000-005 50-04000-083
Description 117V Input, 5V Output Power Supply 220/240V Input, 5V Output Power Supply
Battery Operation: Part Number 25-09075-01 20-10615-01
Description Straight Cable Battery Box (5V Regulated)
Adapter Cables: Part Number 20-03113-02 20-03114-02 20-03115-02 20-03116-02
Connector Type Male, 25-Pin (TxD on pin 3) Male, 25-Pin (TxD on pin 2) Female, 25-Pin (TxD on pin 3) Female, 25-Pin (TxD on pin 2)
3-2
Page 18
LT 1820 Product Reference Guide: Maintenance and Specifications
Coiled Extension Cables: Part Number 25-08892-01
Description 3-foot Extension Cable
Optional Accessories: LT 1820 optional accessories, supplied at extra cost, include additional units of any item list of Standard Accessories, and the following items. Part Number 20-12769-01 20-08414-01 20-08415-01 21-08288-02 23-08253-01 20-08416-01
Description Hands-Free Stand - Desk Mount (non-adjustable) Hands-Free Stand - Free Standing (adjustable) Hands-Free Stand - ECR Mount (adjustable) Desk-Mount Stand Wall-Mount Stand Holster/Belt Clip
Host interface cable pinouts begin on Interface Cable Pinouts on page 3-7.
3-3
Page 19
LT 1820 Product Reference Guide: Maintenance and Specifications
Technical Specifications ITEM
DESCRIPTION
Power Requirements
5 VDC ±10%; 120 mA average current (160 mA peak)
Off Current Stand-By Mode
10 µA
Decode Capability
The LT 1820 scanner can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, Discrete 2 of 5, and Code 93. Set code length(s) for any 2 of 5 code type. Full autodiscrimination as required.
Beeper Operation
User-selectable: Enable, Disable
Beeper Volume
User-selectable: Full Volume, Low Volume
Decode Depth of Field
Maximum typical working distance is 5.0 in. (12.70 cm) (100% UPC/EAN); minimum element width resolution is 5.5 mils
Scan Repetition Rate
40 (± 3) scans/sec. (bidirectional)
Skew Tolerance
± 35˚ min. (from normal)
Pitch Tolerance
-20° to +60˚ (from normal)
Print Contrast Minimum
25% minimum reflectance differential, measured at 675 nm.
Ambient Light Immunity
Immune to direct exposure to normal office and factory lighting conditions, as well as direct exposure to sunlight.
Durability
5 ft (152 cm) drops to concrete
Operating Temperature
32˚ to 104˚ F (0˚ to 40˚ C)
Storage Temperature
-40˚ to 140˚ F (-40˚ to 60˚ C)
Straight Cable Length
6 ft (183 cm)
Weight (without cable)
6.0 oz. (170 gm)
3-4
Page 20
LT 1820 Product Reference Guide: Maintenance and Specifications
LT 1820 Dimensions Nose Width: 2.8 in (7.1 cm)
Table Height: 2.4 in (6.1 cm)
Length: 8.0 in (20.3 cm) Height: 1.8 in (4.6 cm)
Handle Width: 2.0 in (5.1 cm)