Page 41

LT 1820 Product Reference Guide: Programming the LT 1820

Code 39 Buffering (Scan and Store) While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer on page 4-17) or clear the buffer.

Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, unit gives hi/lo beep to indicate successful decode and buffering. See Overfilling Transmission Buffer on page 4-17. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission will occur.

Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission will occur.

4-16

Page 42

LT 1820 Product Reference Guide: Programming the LT 1820

Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. • The unit signals that the transmission buffer has been sent (a lo/hi beep). • Unit sends the buffer. • Unit clears the buffer.

2. A Code 39 bar code with leading character other than a space. • The unit signals that a good decode and buffering of that decode has occurred by giving a lo/hi beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted.

Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission will occur.

Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty.

4-17

Page 43

LT 1820 Product Reference Guide: Programming the LT 1820

Communication Protocols Hardware Handshaking The data interface consists of an RS-232C port. See Interface Cable Pinouts beginning on page 3-7. The port has been designed to operate either with or without hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send. If RTS/CTS handshaking has not been selected, scan data will be transmitted as it becomes available. If optional RTS/CTS handshaking has been selected, the DTR signal is hardwired active, and the unit proceeds as follows: • Examine CTS. If CTS is not asserted by the host, RTS will be asserted by the scanner. If CTS is asserted by the host, the scanner will wait up to 2 seconds for CTS to be negated. • When the host asserts CTS in response to, and within 2 seconds of, the scanner's RTS, data will be transmitted. • The scanner will negate RTS after sending the last character. • The host should respond by negating CTS. The scanner will not wait for this negation, but rather will check before the next transmission, as above. • If the above communication attempt should fail for any reason, the scanner will issue an error beep to alert the operator that the data was not successfully transmitted. In this case, the data is lost and must be rescanned.

4-18

Page 44

LT 1820 Product Reference Guide: Programming the LT 1820

Software Handshaking The scanner also provides two software handshaking options, ENQ and ACK/ NAK, selected by parameter menus. These software handshaking options operate in addition to, and are subordinate to, the hardware handshaking. They can be used separately, in conjunction with each other, or not at all. They operate in the following manner: • When the ENQ is enabled, the scanner waits for an ENQ, Enquire, character from the host before it transmits data. The host must respond in approximately 2 seconds or the scanning unit will beep 4 times, indicating transmission error and loss of the last scanned data. • When the ACK/NAK is enabled, after the scanning unit has transmitted data, it looks for one of the following responses: <ACK> acknowledging a valid accepted transmission, or <NAK> indicating a problem with the transmission. The scanner then will retransmit the data. After three unsuccessful transmission attempts, the unit will abort any further communication attempts on the current message. It indicates this by sounding 4 long (1 second) beeps.

4-19

Page 45

LT 1820 Product Reference Guide: Programming the LT 1820

LT 1820 Hardware and Software Handshaking Sequence HARDWARE HANDSHAKING

YES

SYMBOL IS DECODED

RTS AND CTS HANDSHAKING LINES USED?

UNIT ASSERTS REQUEST-TO-SEND LINE. HOST RESPONDS BY ASSERTING CLEAR-TO-SEND LINE.

NO

NO RESPONSE. AFTER 2 SECONDS THE UNIT BEEPS 4 TIMES TO INDICATE A TRANSMISSION ERROR.

SOFTWARE HANDSHAKING ENQ SWITCH ON? NO

YES WAIT FOR ENQ CHARACTER TO BE RECEIVED FROM HOST.

NO RESPONSE. AFTER 2 SECONDS THE UNIT BEEPS 4 TIMES TO INDICATE A TRANSMISSION ERROR.

DATA IS TRANSMITTED.

ACK/NAK SWITCH ON? YES

NO

WAIT FOR ACK OR NAK RESPONSE FROM HOST.

ACK RESPONSE?

NO

YES NO RESPONSE. AFTER 2 SECONDS THE UNIT BEEPS 4 TIMES TO INDICATE A TRANSMISSION ERROR.

TRY 3 TIMES?

NO

YES, 4 LONG BEEPS

FINISHED

4-20

Page 46

LT 1820 Product Reference Guide: Programming the LT 1820

ASCII Character Set ASCII

VALUE

NUL SOH STX ETX EOT ENQ ACK BELL BACK SPACE HORIZ TAB LF/NEW LINE VT FF CR/ENTER SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

000 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031

ASCII SP ! " # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

VALUE 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063

ASCII @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ --

4-21

VALUE 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095

ASCII ' a b c d e f g h i j k l m n o p q r s t u v w x y z { } ~ DEL

VALUE 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Page 47

Chapter 5 Parameter Menus Set Default To select the Set Default parameter, scan the SET DEFAULT bar code. Scanning this automatically reconfigures the value of each parameter to its default value.

SET DEFAULT

5-1

Page 48

LT 1820 Product Reference Guide: Parameter Menus

Code Types These two options either add or delete a code type.

To add/delete a code: 1. Scan the ENABLE or DISABLE bar code. 2. Scan the bar code corresponding to the code type to be added or deleted. 3. Scan ENTER.

ENABLE

DISABLE

CODE 39

CODE 39 FULL ASCII

5-2

Page 49

LT 1820 Product Reference Guide: Parameter Menus

CODE 93

CODE 128

UPC/EAN

CODABAR

INTERLEAVED 2 OF 5

5-3

Page 50

LT 1820 Product Reference Guide: Parameter Menus

DISCRETE 2 OF 5

ALL CODES

BACKSPACE - deletes the last bar code scanned. CANCEL - deletes the entire change and returns the user to the decode mode. ENTER - stores and enters the new change.

BACKSPACE

ENTER

CANCEL

5-4