Page 61
LS 4800/4900 Product Reference Guide
Code Type (Continued)
<FN3>1000101
<FN3>1000100
Enable Code 128
Disable Code 128
<FN3>1040331
<FN3>1040330
Enable UCC/EAN-128
Disable UCC/EAN-128
<FN3>1000071
<FN3>1000070
Enable Codabar
Disable Codabar
<FN3>1000061
<FN3>1000060
Enable I 2 of 5
Disable I 2 of 5
<FN3>1000051
<FN3>1000050
Enable Discrete 2 Of 5
Disable Discrete 2 Of 5
5-12
Page 62
Programming the LS 4800
Code Type (Continued)
<FN3>1000141
<FN3>1000140
Enable MSI Plessey
Disable MSI Plessey
<FN3>1000231
<FN3>1000230
Enable Bookland EAN
Disable Bookland EAN
<FN3>1000241
<FN3>1000240
Enable UPC/EAN Coupon Code
Disable UPC/EAN Coupon Code
<FN3>1000161
<FN3>1000160
Enable PDF417
Disable PDF417
<FN3>1000341
<FN3>1000340
Enable MICROPDF417
Disable MICROPDF417
5-13
Page 63
LS 4800/4900 Product Reference Guide
Code Lengths Code lengths for certain one-dimensional code types (i.e., Code 39, Codabar, etc.) may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. !
Length Within Range - This option allows you to decode a one-dimensional code type within a specified range. For example, to decode Code 39 characters containing between 4 and 12 characters, first scan CODE 39 LENGTH WITHIN RANGE. Then scan 0, 4, 1 and 2 (single-digit numbers must always be preceded by a leading zero).
!
One Discrete Length - This option allows you to decode only those one-dimensional codes containing a selected length. For example, if you select CODABAR - ONE DISCRETE LENGTH, then scan 1 and 4, the only Codabar codes decoded are those containing 14 characters. No discrete lengths can be set for Code 128.
!
Two Discrete Lengths - This option allows you to decode only those one-dimensional codes containing two selected lengths. For example, if you select I 2 OF 5 TWO DISCRETE LENGTHS, then scan 0, 2, 1, 4, the only Interleaved 2 of 5 codes decoded are those containing 2 or 14 characters. No discrete lengths can be set for Code 128.
!
Any Length - Scanning this option allows you to decode the selected one-dimensional code type containing any number of characters. For example, if you scan CODABAR ANY LENGTH, you can decode a Codabar symbol containing any number of characters.
5-14
Page 64
Programming the LS 4800
Code Lengths (Continued) To select two lengths for each code type: 1. Scan the desired option. 2. Scan two numeric bar codes from page 20 for each desired length. For example, for a length of “12”, scan “1” then “2”. For a length of “3”, scan “0”, then “3”. You must always scan two bar codes for each length. 3. If you make an error, or wish to change your selection, scan Cancel on page 5-20.
<FN3>F0010001013700000
<FN3>F3010001013700000
Code 39 Any Length
Code 39 Length Within Range
<FN3>F1010001013700000
<FN3>F2010001013700000
Code 39 1 Discrete Length
Code 39 2 Discrete Lengths
5-15
Page 65
LS 4800/4900 Product Reference Guide
Code Lengths (Continued)
<FN3>F0010A0B023700011 Code 93 Any Length
<FN3>F3010A0B023700011 Code 93 Length Within Range
<FN3>F1010A0B023700011 Code 93 1 Discrete Length
<FN3>F2010A0B003700011 Code 93 2 Discrete Lengths
5-16
Page 66
Programming the LS 4800
Code Lengths (Continued)
<FN3>F0010203003700007 Codabar Any Length
<FN3>F3010203013700007 Codabar Length Within Range
<FN3>F1010203013700007 Codabar 1 Discrete Length
<FN3>F2010203013700007 Codabar 2 Discrete Lengths
5-17
Page 67
LS 4800/4900 Product Reference Guide
Code Lengths (Continued)
5-18
<FN3>F0010809003700006
<FN3>F3010809023700006
I 2 Of 5 - Any Length
I 2 Of 5 - Length Within Range
<FN3>F1010809023700006
<FN3>F2010809023700006
I 2 Of 5 1 Discrete Length
I 2 Of 5 2 Discrete Lengths
<FN3>F0010607023700005
<FN3>F3010607023700005
D 2 Of 5 Any Length
D 2 Of 5 Length Within Range
<FN3>F1010607023700005
<FN3>F2010607003700005
D 2 Of 5 1 Discrete Length
D 2 Of 5 2 Discrete Lengths
Page 68
Programming the LS 4800
Code Lengths (Continued)
<FN3>F0010F10013700014 MSI Plessey - Any Length
<FN3>F3010F10013700014 MSI Plessey - Length Within Range
<FN3>F1010F10013700014 MSI Plessey 1 Discrete Length
<FN3>F2010F10003700014 MSI Plessey 2 Discrete Lengths
5-19
Page 69
LS 4800/4900 Product Reference Guide
Code Lengths (Continued)
<FN3>A0
<FN3>A1
0
1
<FN3>A2
<FN3>A3
2
3
<FN3>A4
<FN3>A5
4
5
<FN3>A6
<FN3>A7
6
7
<FN3>A8
<FN3>A9
8
9
<FN3>ACancel
5-20
Page 70
Programming the LS 4800
Decode Options Transmit UPC-E/UPC-A Check Digit Select if decoded UPC symbols are transmitted with or without a check digit.
<FN3>1020021
<FN3>1020020
Transmit UPC-A Check Digit
Do Not Transmit UPC-A Check Digit
<FN3>1020031
<FN3>1020030
Transmit UPC-E Check Digit
Do Not Transmit UPC-E Check Digit
Convert UPC-E to UPC-A Use this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
<FN3>1020001
<FN3>1020000
Convert UPC-E To UPC-A
Do Not Convert UPC-E To UPC-A
5-21