Page 51
LS 4800/4900 Product Reference Guide
Set Default Parameter Scanning the SET DEFAULT bar code returns all parameters to the values listed in the Table 5-1 and Table 5-2.
<FN3>91 Set Defaults
5-2
Page 52
Programming the LS 4800
Parameter Selections and Defaults Table 5-1 and Table 5-2 provides parameter selections and their defaults for general and Macro PDF parameters. Table 5-1. General Parameter Table Parameter Set Defaults
Selection None
Default Set Default Values
Add / Delete Codes to be Decoded UPC-A, UPC-E, EAN-8, EAN- UPC-A/E, 13, Code 128, Code 39, Code EAN-8/13, 39 Full ASCII, Trioptic Code Code 128, Code 39, 39, Code 93, Codabar, UCC/EAN 128, Interleaved 2 of 5, Discrete 2 of PDF417, 5, MicroPDF417 UCC/EAN 128, Bookland EAN, UPC Coupon Code, MSI Plessey, PDF417, MicroPDF417 Code 39 Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Length Within Range: 01-55
Code 93 Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Length Within Range: 04-55
Codabar Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Length Within Range: 02-55
Interleaved 2 of 5 Lengths
Any Length, Length Within Range (2 to 54 characters), 1 or 2 Discrete Lengths
1 Discrete Length 14
Discrete 2 of 5 Lengths
Any Length, Length Within Range (2 to 54 characters), 1 or 2 Discrete Lengths
1 Discrete Length 12
MSI Plessey Lengths
Any Length, Length Within Range, 1 or 2 Discrete Lengths
Any Length
Transmit UPC-A Check Digit
Enabled, Disabled
Enabled
Transmit UPC-E Check Digit
Enabled, Disabled
Enabled
Convert UPC-E to UPC-A
Enabled, Disabled
Disabled
Code 39 Check Digit Verification Enabled, Disabled
Disabled
Decode Options:
5-3
Page 53
LS 4800/4900 Product Reference Guide
Table 5-1. General Parameter Table (Continued) Parameter
5-4
Selection
Default
Transmit Code 39 Check Digit
Enabled, Disabled
Disabled
I 2 of 5 Check Digit Verification
Enabled, Disabled
Disabled
Transmit I 2 of 5 Check Digit
Enabled, Disabled
Disabled
Convert I 2 of 5 to EAN-13
Enabled, Disabled
Disabled
MSI Plessey Check Digits
One, Two
One
Transmit MSI Plessey Check Digit Enabled, Disabled
Disabled
MSI Plessey Check Digit Algorithm
Mod 10/Mod 10, Mod 10/Mod 11
Mod 10/Mod 10
Convert EAN-8 to EAN-13
Enabled, Disabled
Enabled
Decode UPC/EAN Supplemental
Enabled, Disabled, Auto
Disabled
CLSI Editing
Enabled, Disabled
Disabled
NOTIS Editing
Enabled, Disabled
Disabled
Transmit Code ID Character
Enabled, Symbol Std., AIM Std. Disabled
Buffer Output Data
Enabled, Disabled
Disabled
Transmit “No Decode” Message
Enabled, Disabled
Disabled
Transmit LRC Checksum
Enabled, Disabled
Disabled
UPC-A Preamble
None, System Character, System None Character & Country Code
UPC-E Preamble
None, System Character, System None Character & Country Code
Code 128 Emulation
Enabled, Disabled
Enabled
UCC/EAN-128 Emulation
Decode, Ignore, Autodiscriminate Linked Symbol
Ignore
Pause Duration
0.0 to 9.9 seconds
0.0 seconds
Prefix Suffix Values
4-Digit ASCII Value
Enter
Scan Data Transmission Format
<Data>; <Data><Suffix>; <Prefix><Data><Suffix>; <Prefix><Data>
<Data>
Page 54
Programming the LS 4800
Table 5-1. General Parameter Table (Continued) Parameter
Selection
Default
Scanning Options: Decode Attempt Duration
0.0 to 9.9 seconds
5 seconds
Scanning Mode
Smart Raster, Always Raster, Slab Only Raster, Programmable Raster
Smart Raster
Raster Height
01 - 15
15
Raster Expansion
01 - 15
11
Aiming Mode
Aiming Dot, Slab Raster
Slab Raster
Beep After Good Decode
Enabled, Disabled
Enabled
Beeper Tone
High, Medium, Low
High
Time Delay to Low Power
30 sec., 1, 2, 3 minutes
30 Seconds
Timeout Bet. Same Symbol
0.0 to 9.9 seconds
0.6 Seconds
Timeout Bet. Diff. Symbols
0.0 to 9.9 seconds
0.0 Seconds
2 - 20
7
Linear Code Type Security Levels 1 - 4
1
Bi-directional Redundancy
Enabled, Disabled
Disabled
UPC/EAN Security Levels
0-3
1
Baud Rate
300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4 K
9600
Parity
Even, Odd, Mark, Space, None None
Check Parity of Received Data
Enabled, Disabled
Enabled
Stop Bit Select
One, Two
One
Hardware Handshaking
None, RTS/CTS Options 1, 2, 3 None
Scan Stand Options:
Security Options: Decode UPC/EAN Supplemental Redundancy
Host Port RS-232 Options:
5-5
Page 55
LS 4800/4900 Product Reference Guide
Table 5-1. General Parameter Table (Continued) Parameter
Selection
Default
Software Handshaking
None, ENQ, ACK/NAK, ACK/ None NAK with ENQ, XON/XOFF
Intercharacter Delay
00 - 99 ms.
0
Host Serial RTS Line State
Low RTS, High RTS
Low RTS
Serial Response Time-out
00 - 9.9 seconds
2.0 seconds
Beep on <BEL>
Enabled, Disabled
Disabled
ASCII Format
7-Bit ASCII, 8-Bit ASCII
8-Bit ASCII
Table 5-2. Macro PDF Parameter Table Parameter
Selection
Default
Macro PDF Transmit/Decode Mode
Buffer All Symbols / Transmit Buffer All Symbols / Transmit Macro PDF When Complete Macro PDF When Complete Transmit Any Symbol in Set / No Particular Order Scan in Sequence Only / Transmit in Sequence Without Buffering Buffer Scans Out of Order / Transmit Scans in Order
Transmit Each Symbol in Codeword Format
Enabled or Disabled
Disabled
ESC Characters
ECI Protocol, GLI Protocol, None
None
Delete Character Set ECIs
Delete Character Set ECIs, Transmit Character Set ECIs
Enabled
ECI Decoder
Enabled, Disabled
Enabled
Transmit Unknown Codewords
Enabled or Disabled
Disabled
5-6
Page 56
Programming the LS 4800
Table 5-2. Macro PDF Parameter Table (Continued) Parameter
Selection
Default
Transmit Macro PDF User-Selected Field: Transmit File Name
Enabled, Disabled
Disabled
Transmit Block Count
Enabled, Disabled
Disabled
Transmit Time Stamp
Enabled, Disabled
Disabled
Transmit Sender
Enabled, Disabled
Disabled
Transmit Addresses
Enabled, Disabled
Disabled
Transmit File Size
Enabled, Disabled
Disabled
Transmit Checksum
Enabled, Disabled
Disabled
Transmit Macro PDF Control Header
Enabled, Disabled
Disabled
Last Block Marker
Enabled, Disabled
Disabled
5-7
Page 57
LS 4800/4900 Product Reference Guide
Host Selection This determines whether the LS 4800 interfaces with an RS-232C host, a Synapse host, or no host.
<FN3>2050A37 RS-232 Host
SYNAPSE HOST Note that the bar code for making this selection is in the Interface Guide which accompanies the interface cable.
<FN3>2050AFE Null Host
5-8
Page 58
Programming the LS 4800
Code Type The bar code menu selections enable the scanner to decode any or all of the following symbologies. !
UPC Versions A and E (EAN 8 and 13) •
Code 128
!
Code 39
•
UCC/EAN 128
!
Code 39 Full ASCII
•
Interleaved 2 of 5
!
Trioptic Code 39
•
Discrete 2 of 5
!
Code 93
•
MSI Plessey
!
Codabar
•
PDF417
!
Bookland EAN
•
MicroPDF417
!
UPC Coupon Code
The integrated decoder autodiscriminates between all of the above symbologies, except for Code 39 and Code 39 Full ASCII.
Code 39 / Code 39 Full ASCII The ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters, such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code control character ($ + % /) preceding a Code 39 symbol and assigns an ASCII character value. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M outputs the keystroke equivalent of “ABC ENTER”. The LS 4800's integrated decoder autodiscriminates between Code 39 and Code 39 Full ASCII.
5-9
Page 59
LS 4800/4900 Product Reference Guide
Code Type (Continued)
5-10
<FN3>1000011
<FN3>1000010
Enable UPC-A
Disable UPC-A
<FN3>1000021
<FN3>1000020
Enable UPC-E
Disable UPC-E
<FN3>1000041
<FN3>1000040
Enable EAN-8
Disable EAN-8
<FN3>1000031
<FN3>1000030
Enable EAN-13
Disable EAN-13
Page 60
Programming the LS 4800
Code Type (Continued)
<FN3>1000001
<FN3>1000000
Enable Code 39
Disable Code 39
<FN3>1020111 Enable Code 39 Full ASCII
<FN3>1020110 Disable Code 39 Full ASCII
<FN3>1000221
<FN3>1000220
Enable Trioptic Code 39
Disable Trioptic Code 39
<FN3>1000111
<FN3>1000110
Enable Code 93
Disable Code 93
5-11