Page 51

LS 4800/4900 Product Reference Guide

Set Default Parameter Scanning the SET DEFAULT bar code returns all parameters to the values listed in the Table 5-1 and Table 5-2.

<FN3>91 Set Defaults

5-2

Page 52

Programming the LS 4800

Parameter Selections and Defaults Table 5-1 and Table 5-2 provides parameter selections and their defaults for general and Macro PDF parameters. Table 5-1. General Parameter Table Parameter Set Defaults

Selection None

Default Set Default Values

Add / Delete Codes to be Decoded UPC-A, UPC-E, EAN-8, EAN- UPC-A/E, 13, Code 128, Code 39, Code EAN-8/13, 39 Full ASCII, Trioptic Code Code 128, Code 39, 39, Code 93, Codabar, UCC/EAN 128, Interleaved 2 of 5, Discrete 2 of PDF417, 5, MicroPDF417 UCC/EAN 128, Bookland EAN, UPC Coupon Code, MSI Plessey, PDF417, MicroPDF417 Code 39 Lengths

Any Length, Length Within Range, 1 or 2 Discrete Lengths

Length Within Range: 01-55

Code 93 Lengths

Any Length, Length Within Range, 1 or 2 Discrete Lengths

Length Within Range: 04-55

Codabar Lengths

Any Length, Length Within Range, 1 or 2 Discrete Lengths

Length Within Range: 02-55

Interleaved 2 of 5 Lengths

Any Length, Length Within Range (2 to 54 characters), 1 or 2 Discrete Lengths

1 Discrete Length 14

Discrete 2 of 5 Lengths

Any Length, Length Within Range (2 to 54 characters), 1 or 2 Discrete Lengths

1 Discrete Length 12

MSI Plessey Lengths

Any Length, Length Within Range, 1 or 2 Discrete Lengths

Any Length

Transmit UPC-A Check Digit

Enabled, Disabled

Enabled

Transmit UPC-E Check Digit

Enabled, Disabled

Enabled

Convert UPC-E to UPC-A

Enabled, Disabled

Disabled

Code 39 Check Digit Verification Enabled, Disabled

Disabled

Decode Options:

5-3

Page 53

LS 4800/4900 Product Reference Guide

Table 5-1. General Parameter Table (Continued) Parameter

5-4

Selection

Default

Transmit Code 39 Check Digit

Enabled, Disabled

Disabled

I 2 of 5 Check Digit Verification

Enabled, Disabled

Disabled

Transmit I 2 of 5 Check Digit

Enabled, Disabled

Disabled

Convert I 2 of 5 to EAN-13

Enabled, Disabled

Disabled

MSI Plessey Check Digits

One, Two

One

Transmit MSI Plessey Check Digit Enabled, Disabled

Disabled

MSI Plessey Check Digit Algorithm

Mod 10/Mod 10, Mod 10/Mod 11

Mod 10/Mod 10

Convert EAN-8 to EAN-13

Enabled, Disabled

Enabled

Decode UPC/EAN Supplemental

Enabled, Disabled, Auto

Disabled

CLSI Editing

Enabled, Disabled

Disabled

NOTIS Editing

Enabled, Disabled

Disabled

Transmit Code ID Character

Enabled, Symbol Std., AIM Std. Disabled

Buffer Output Data

Enabled, Disabled

Disabled

Transmit “No Decode” Message

Enabled, Disabled

Disabled

Transmit LRC Checksum

Enabled, Disabled

Disabled

UPC-A Preamble

None, System Character, System None Character & Country Code

UPC-E Preamble

None, System Character, System None Character & Country Code

Code 128 Emulation

Enabled, Disabled

Enabled

UCC/EAN-128 Emulation

Decode, Ignore, Autodiscriminate Linked Symbol

Ignore

Pause Duration

0.0 to 9.9 seconds

0.0 seconds

Prefix Suffix Values

4-Digit ASCII Value

Enter

Scan Data Transmission Format

<Data>; <Data><Suffix>; <Prefix><Data><Suffix>; <Prefix><Data>

<Data>

Page 54

Programming the LS 4800

Table 5-1. General Parameter Table (Continued) Parameter

Selection

Default

Scanning Options: Decode Attempt Duration

0.0 to 9.9 seconds

5 seconds

Scanning Mode

Smart Raster, Always Raster, Slab Only Raster, Programmable Raster

Smart Raster

Raster Height

01 - 15

15

Raster Expansion

01 - 15

11

Aiming Mode

Aiming Dot, Slab Raster

Slab Raster

Beep After Good Decode

Enabled, Disabled

Enabled

Beeper Tone

High, Medium, Low

High

Time Delay to Low Power

30 sec., 1, 2, 3 minutes

30 Seconds

Timeout Bet. Same Symbol

0.0 to 9.9 seconds

0.6 Seconds

Timeout Bet. Diff. Symbols

0.0 to 9.9 seconds

0.0 Seconds

2 - 20

7

Linear Code Type Security Levels 1 - 4

1

Bi-directional Redundancy

Enabled, Disabled

Disabled

UPC/EAN Security Levels

0-3

1

Baud Rate

300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4 K

9600

Parity

Even, Odd, Mark, Space, None None

Check Parity of Received Data

Enabled, Disabled

Enabled

Stop Bit Select

One, Two

One

Hardware Handshaking

None, RTS/CTS Options 1, 2, 3 None

Scan Stand Options:

Security Options: Decode UPC/EAN Supplemental Redundancy

Host Port RS-232 Options:

5-5

Page 55

LS 4800/4900 Product Reference Guide

Table 5-1. General Parameter Table (Continued) Parameter

Selection

Default

Software Handshaking

None, ENQ, ACK/NAK, ACK/ None NAK with ENQ, XON/XOFF

Intercharacter Delay

00 - 99 ms.

0

Host Serial RTS Line State

Low RTS, High RTS

Low RTS

Serial Response Time-out

00 - 9.9 seconds

2.0 seconds

Beep on <BEL>

Enabled, Disabled

Disabled

ASCII Format

7-Bit ASCII, 8-Bit ASCII

8-Bit ASCII

Table 5-2. Macro PDF Parameter Table Parameter

Selection

Default

Macro PDF Transmit/Decode Mode

Buffer All Symbols / Transmit Buffer All Symbols / Transmit Macro PDF When Complete Macro PDF When Complete Transmit Any Symbol in Set / No Particular Order Scan in Sequence Only / Transmit in Sequence Without Buffering Buffer Scans Out of Order / Transmit Scans in Order

Transmit Each Symbol in Codeword Format

Enabled or Disabled

Disabled

ESC Characters

ECI Protocol, GLI Protocol, None

None

Delete Character Set ECIs

Delete Character Set ECIs, Transmit Character Set ECIs

Enabled

ECI Decoder

Enabled, Disabled

Enabled

Transmit Unknown Codewords

Enabled or Disabled

Disabled

5-6

Page 56

Programming the LS 4800

Table 5-2. Macro PDF Parameter Table (Continued) Parameter

Selection

Default

Transmit Macro PDF User-Selected Field: Transmit File Name

Enabled, Disabled

Disabled

Transmit Block Count

Enabled, Disabled

Disabled

Transmit Time Stamp

Enabled, Disabled

Disabled

Transmit Sender

Enabled, Disabled

Disabled

Transmit Addresses

Enabled, Disabled

Disabled

Transmit File Size

Enabled, Disabled

Disabled

Transmit Checksum

Enabled, Disabled

Disabled

Transmit Macro PDF Control Header

Enabled, Disabled

Disabled

Last Block Marker

Enabled, Disabled

Disabled

5-7

Page 57

LS 4800/4900 Product Reference Guide

Host Selection This determines whether the LS 4800 interfaces with an RS-232C host, a Synapse host, or no host.

<FN3>2050A37 RS-232 Host

SYNAPSE HOST Note that the bar code for making this selection is in the Interface Guide which accompanies the interface cable.

<FN3>2050AFE Null Host

5-8

Page 58

Programming the LS 4800

Code Type The bar code menu selections enable the scanner to decode any or all of the following symbologies. !

UPC Versions A and E (EAN 8 and 13) •

Code 128

!

Code 39

•

UCC/EAN 128

!

Code 39 Full ASCII

•

Interleaved 2 of 5

!

Trioptic Code 39

•

Discrete 2 of 5

!

Code 93

•

MSI Plessey

!

Codabar

•

PDF417

!

Bookland EAN

•

MicroPDF417

!

UPC Coupon Code

The integrated decoder autodiscriminates between all of the above symbologies, except for Code 39 and Code 39 Full ASCII.

Code 39 / Code 39 Full ASCII The ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters, such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code control character ($ + % /) preceding a Code 39 symbol and assigns an ASCII character value. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M outputs the keystroke equivalent of “ABC ENTER”. The LS 4800's integrated decoder autodiscriminates between Code 39 and Code 39 Full ASCII.

5-9

Page 59

LS 4800/4900 Product Reference Guide

Code Type (Continued)

5-10

<FN3>1000011

<FN3>1000010

Enable UPC-A

Disable UPC-A

<FN3>1000021

<FN3>1000020

Enable UPC-E

Disable UPC-E

<FN3>1000041

<FN3>1000040

Enable EAN-8

Disable EAN-8

<FN3>1000031

<FN3>1000030

Enable EAN-13

Disable EAN-13

Page 60

Programming the LS 4800

Code Type (Continued)

<FN3>1000001

<FN3>1000000

Enable Code 39

Disable Code 39

<FN3>1020111 Enable Code 39 Full ASCII

<FN3>1020110 Disable Code 39 Full ASCII

<FN3>1000221

<FN3>1000220

Enable Trioptic Code 39

Disable Trioptic Code 39

<FN3>1000111

<FN3>1000110

Enable Code 93

Disable Code 93

5-11