The text of a manual · part 5 of 24
LS 4800/4900 Product Reference Guide, pages 41 to 50
Pages 41 to 50 of 239
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-4804 and Symbol LS-4904
Page 41
LS 4800/4900 Product Reference Guide
1. Per instructions on using your charger, mount the adapter on the charger. Many chargers accommodate multiple adapters. 2. After the battery pack is fully charged, insert the battery pack in the scanner’s handle. Slide the charged battery up into handle until it locks securely into place.
What If ... Nothing happens when you follow the operating instructions? !
Check the system power.
!
Make sure you are using the correct interface cable for the host device.
!
Check for loose cable connections.
!
Make sure the scanner is programmed to read the symbology you are trying to read. See Chapter 5, Programming the LS 4800.
!
Check the label to make sure it is not defaced; if damaged beyond its error correction capability, it will not decode.
!
Try scanning a test symbol of the symbology you are trying to read.
Your terminal operates but scanned data is not displayed correctly? !
Check the system power.
!
Check for loose cable connections.
!
If you’re working with a Synapse cable, refer to your Installation Guide.
!
Check that the communication parameters (baud rate, parity, stop bits, etc.) are set properly for the receiving device.
The laser does not activate, which is followed by a beep sequence? !
You may be scanning in an inappropriately hot environment. Remove the scanner from the environment, or allow the laser to cool down.
Transmitting PDF bar code data through a scanner/wand emulation Synapse cable causes transmit errors? !
4-4
The scanner / wand emulation Synapse cable has a transmission limit of approximately 46 characters. This does not apply to other Synapse cables.
Page 42
Maintenance and Specifications
Accessories Required Accessories These items must be included to complete the system. The following are available through contacting your local Symbol representative or business partner. !
Host Interface Cables for RS-232 Operation (Available in 6’ and 14’ lengths): " 25-Pin, Male, D Connector (TxD on Pin 3) " 25-Pin, Male, D Connector (TxD on Pin 2) " 25-Pin, Female, D Connector (TxD on Pin 3) " 25-Pin, Female, D Connector (TxD on Pin 2) " 9-Pin, Female, D Connector (PC AT: TxD on Pin 3)
!
Portable Terminal Interface Cables: " Cable for PDT 3300 (Serial TTL 9-Pin Connector) " Cable for PDT 3300 (Modular Connector)
!
Synapse Adapter Cable
!
Power Supply (Select One): " 115 VAC Power Supply " 220/240 VAC Power Supply (Europe) " 100 VAC Power Supply (Japan)
!
User Documentation " LS 4800 Product Reference Guide
Optional Accessories These items are not included in the standard configuration. The following are available through contacting your local Symbol representative or business partner. !
Battery Pack Unit / NiCad
!
NiCd Battery Adapter for Four-Slot Charger
!
NiCd Battery Adapter for UBC 1000 Charger
!
Retractable Pulley
!
Utility Belt
!
Snap-On Protective Boot (with Metal Loop)
!
IntelliStand 4-5
Page 43
LS 4800/4900 Product Reference Guide
!
Under Register Stand
!
Wall Mount Stand
!
Free Standing Stand (height 5” - 8”)
!
ECR Stand
LS 4800 Scanner Specifications Table 4-1 lists the specifications for the LS 4800 scanner. Table 4-1. Scanner Specifications Item
Description
Power Requirements
+5 V, 400 mA Typical
Laser Diode Power
1.0 mW, max.
Scan Pattern: Start Time
0.065 sec. to 75% of steady state horizontal amplitude; 0.50 sec. to 90% of steady state vertical amplitude
Scan Angle
LS 4800, LS 4900: 34o ± 2o LS 4804 VHD: 24o ± 2o
Scan Rate
560 scans/sec. 280 Hz ±15 Hz (horizontal)
Frame Rate
25 frames/sec. 12.5 Hz ±1 Hz (vertical)
Optical Resolution
Can decode a 6.6 mil (minimum X-dimension) symbol (PDF417); Y-dimension must be 2X or greater. VHD version: 4 mil minimum
Angular Orientation Tolerances: Pitch Tolerance
± 30o (“front to back”)
Skew
± 15o from plane parallel to symbol (“side-to-side”)
Rotational Tolerance
± 4o (for scanning benchmark label, assuming 3:1 codeword aspect ratio)
Dead Zone/Optical Throw
± 2o (1-D symbologies) or ± 9o(PDF417) from beam direction
Print Contrast Resolution
25% (1-D symbologies) or 35% (PDF417) absolute dark/light reflectance differential, measured at 650 nm.
Ambient Light Immunity
Up to 8000 ft-candles of sunlight
Humidity
5 - 95% (non-condensing)
Shock
LS 4804: 5-ft drop to concrete LS 4904: 4-ft drop to concrete
4-6
Page 44
Maintenance and Specifications
Table 4-1. Scanner Specifications (Continued) Item
Description
Environmental Sealing
MIL-STD-810E windblown dust and rain
Operating Temperature
-20o to 40o C; -4o to 104o F
Storage Temperature
-40o to 60o C; -40o to 140o F
Scanner Connector
10-pin modular connector at base of handle Pin 1: + 5V power supply Pin 2: Trigger signal output/input Pin 3: Transmit (TxD) Pin 4: Receive (RxD) Pin 5: Ready to Send (RTS) Pin 6: Clear to Send (CTS) Pin 7: Synapse control data Pin 8: Synapse control clock Pin 9: Ground Pin 10: Data Terminal Ready (DTR)
Coil Cable Length
6 ft.; 183 cm
Weight
9 oz; 252 gm (without cable or batteries)
Height
6.72 in.; 17 cm
Length
4.4 in.; 11.2 cm
Width
2.5 in.; 6.4 cm
Agency Approvals
CDRH Class II, IEC 825 Class II, FCC Class A, UL, CSA, VDE, CE
Decode Capability
1-D Symbologies: UPC-A, UPC-E, EAN-8, EAN-13, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 93, Code 128, Codabar, Interleaved 2 of 5, Discrete 2 of 5, UCC/EAN 128, Bookland EAN, UPC Coupon Code, MSI Plessey. Cannot autodiscriminate between Code 39 and Code 39 Full ASCII. 2-D Symbology: PDF417 (up to 928 codewords at security level 0 - 8), MicroPDF417.
Memory
64K RAM, 256K Flash
4-7
Page 45
LS 4800/4900 Product Reference Guide
LS 4900 Battery Pack Specifications Table 4-2 lists the battery pack specifications for the LS 4900. Table 4-2. Battery Pack Specifications Item
Description
Battery Size
5 Prismatic NiCad Cells - 600 mA-hrs
Recharge Time
12 hr. trickle charge
Charging Temperature
+15o to 40o C; 59o to 104o F
Typical Battery Life
300 recharge cycles
Package Weight
5.3 oz; 150.4 gm
Height
3.25 in.; 10.2 cm
Length
1.75 in.; 11.2 cm
Width
1.0 in. ; 3.6 cm
Cable Pinouts The following tables describe the pinouts for connector cables. Table 4-3. Single-Port RS-232C, 25-Pin Male D-Type Connector P/N 25-13523-01 Pin
4-8
Signal
Function
2
RxD
Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line. It may be used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
5
RTS
Request-to-send handshaking output line. It may be used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is hardwired active.
Page 46
Maintenance and Specifications
Table 4-3. Single-Port RS-232C, 25-Pin Male D-Type Connector P/N 25-13523-01 (Continued) Pin 7
Signal Ground
Function Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
Table 4-4. Single-Port RS-232C, 25-Pin Male D-Type Connector P/N 25-13522-01 Pin
Signal
Function
2
TxD
Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line. It may be used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
5
CTS
Clear-to-send handshaking input line. It may be used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is hardwired active.
4-9
Page 47
LS 4800/4900 Product Reference Guide
Table 4-5. Single-Port RS-232C, 25-Pin Female D-Type Connector P/N 25-13525-01 Pin
Signal
Function
2
RxD
Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line. It may be used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
5
RTS
Request-to-send handshaking output line. It may be used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is hardwired active.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
Table 4-6. Single-Port RS-232C, 25-Pin Female D-Type Connector P/N 25-13524-01 Pin
Signal
Function
2
TxD
Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line. It may be used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line
4-10
Page 48
Maintenance and Specifications
Table 4-6. Single-Port RS-232C, 25-Pin Female D-Type Connector P/N 25-13524-01 (Continued) Pin
Signal
Function
5
CTS
Clear-to-send handshaking input line. It may be used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is hardwired active.
Table 4-7. Single-Port RS-232C, 9-Pin Female D-Type Connector (PC/AT) P/N 25-13527-01 Pin
Signal
Function
2
TxD
Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.
5
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
7
CTS
Clear-to-send handshaking input line. It may be used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
8
RTS
Request-to-send handshaking output line. It may be used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
4-11
Page 49
LS 4800/4900 Product Reference Guide
Table 4-8. Single-Port RS-232C, 9-Pin Female D-Type Connector for PDT 3300 Interface Board P/N 25-13521-01 Pin
Signal
Function
1
CTS
Clear-to-send handshaking input line. It may be used optionally by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
2
RxD
Serial data receive input. It is driven by the serial data transmit output on the device communicating with the scanner.
3
RTS
Request-to-send handshaking output line. It may be used optionally by the scanner to signal another device that data is available to send. It can be used only in conjunction with the CTS line.
6
TxD
Serial data transmit output. It drives the serial data receive input on the device communicating with the scanner.
7
Ground
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
Table 4-9. 10-Pin Male Modular Connector for Synapse Cable P/N 25-13526-01 Pin
Signal
Function
1
SYNDATA
Synapse-compatible data line. Bi-directional line.
2
SYNCLK
Synapse-compatible clock line. Bi-directional line.
3
VCC
Power.
4
GND
Power supply ground pin and reference for both output signals. It must be capable of sinking all return current.
4-12
Page 50
Chapter 5 Programming the LS 4800 Before programming, follow the pertinent setup instructions in Chapter 2, Setup. This chapter provides parameter descriptions and programming bar codes. Table 5-1 beginning on page 5-3 shows selectable parameters and standard default values for the LS 4800’s decoder. If the default values suit your requirements, all you need to do is scan the SET DEFAULT bar code. Parameters other than default values can be set by scanning single bar codes or short bar code sequences. Note that all parameter settings are stored in non-volatile memory and so are retained after powerdown.
Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter. For example, if you want to set the baud rate to 9600, simply scan the 9600 bar code listed under section on page 63. The scanner issues a warble tone, signifying a successful parameter entry. If you want to set specific code lengths or specify Serial Response Time-Out, you have to scan several bar codes. This procedure is described later in this chapter.
Errors While Scanning Don't worry if you make an error during a scanning sequence. Merely reenter the correct parameter.
5-1