Page 71

LS 4800/4900 Product Reference Guide

Code 39 Check Digit Verification When enabled, this parameter checks the integrity of a Code 39 symbol to ensure that it complies with specified algorithms. Only those code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled.

<FN3>1020041

<FN3>1020040

Enable Code 39 Check Digit

Disable Code 39 Check Digit

Transmit Code 39 Check Digit When Code 39 Check Digit Verification is enabled, select if you want to transmit data with or without the check digit.

<FN3>1020241

<FN3>1020240

Transmit Code 39 Check Digit (Enable)

Do Not Transmit Code 39 Check Digit (Disable)

5-22

Page 72

Programming the LS 4800

I 2 of 5 Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm, either Uniform Symbology Specification (USS), or Optical Product Code Council (OPCC).

<FN3>2051E00

<FN3>2051E01

Disable

USS Check Digit

<FN3>2051E02 OPCC Check Digit

Transmit I 2 of 5 Check Digit Select if decoded I 2 of 5 symbols are transmitted with or without a check digit.

<FN3>1020211

<FN3>1020210

Transmit I 2 Of 5 Check Digit

Do Not Transmit I 2 Of 5 Check Digit

5-23

Page 73

LS 4800/4900 Product Reference Guide

Convert I 2 of 5 to EAN-13 This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.

<FN3>1020201

<FN3>1020200

Convert I 2 Of 5 To EAN-13

Do Not Convert I 2 Of 5 To EAN-13

MSI Plessey Check Digits These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data.

<FN3>1020120

<FN3>1020121

One MSI Plessey Check Digit

Two MSI Plessey Check Digits

5-24

Page 74

Programming the LS 4800

Transmit MSI Plessey Check Digit Select if you want to transmit data with or without the check digit.

<FN3>1020131

<FN3>1020130

Transmit MSI Plessey Check Digit

Do Not Transmit MSI Plessey Check Digit

MSI Plessey Check Digit Algorithm When the two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Select either the Mod 10/Mod 10 or Mod 10/Mod 11 algorithm.

<FN3>1020230

<FN3>1020231

MOD 10/MOD 11

MOD 10/MOD 10

5-25

Page 75

LS 4800/4900 Product Reference Guide

Convert EAN-8 to EAN-13 This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.

<FN3>1020011 Enable Convert EAN-8 To EAN-13

<FN3>1020010 Disable Convert EAN8 To EAN-13

5-26

Page 76

Programming the LS 4800

Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters. Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the interface scanner is presented with a UPC/EAN plus supplemental symbol, the UPC/EAN is decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LS 4800 scanner transmits either, after additional processing to ensure a good decode. Note: To minimize the risk of invalid data transmission, it is recommended that you select whether to read or ignore supplemental characters. .

<FN3>2010E01

<FN3>2010E00

Decode UPC/EAN Supplementals

Ignore UPC/EAN Supplementals

<FN3>2010E02 Autodiscriminate UPC/EAN Supplementals

5-27

Page 77

LS 4800/4900 Product Reference Guide

CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Note: Symbol length does not include start and stop characters.

<FN3>1020051

<FN3>1020050

Enable CLSI Editing

Disable CLSI Editing

NOTIS Editing When enabled, this parameter strips the start and stop characters from decoded Codabar symbol.

<FN3>1020061

<FN3>1020060

Enable NOTIS Editing

Disable NOTIS Editing

5-28

Page 78

Programming the LS 4800

Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. If a prefix is selected, the code ID character is sent after the prefix and before the decoded symbol. You may select no code ID character, a Symbol code ID character, or an AIM ID character. Symbol code ID characters are listed below. AIM ID characters are listed in the section AIM Code Identifiers on page A-1. Table 5-3. Symbol Code ID Characters Code Type

Symbol Identifier

UPC-A, UPC-E, EAN-13, EAN-8

A

Code 39

B

Codabar

C

Code 128

D

Code 93

E

Interleaved 2 of 5

F

Discrete 2 of 5, D 2 of 5 IATA

G

MSI Plessey

J

UCC/EAN 128

K

Bookland EAN

L

Trioptic Code 39

M

PDF417, MicroPDF417

X

<FN3>2051702

<FN3>2051701

Transmit Symbol Code ID Character

Transmit AIM Code ID Character

<FN3>2051700 Do Not Transmit Code ID Character

5-29

Page 79

LS 4800/4900 Product Reference Guide

Decode Buffering This option permits the scanner to store decode data until the host device is ready to receive them. If the scanner reaches its capacity to store decoded symbols before the host is ready, subsequent trigger pulls have no effect until a buffer is available.

<FN3>2051401

<FN3>2051400

Enable Decode Buffering

Disable Decode Buffering

Transmit “No Decode” Message When this feature is enabled, “FR” is transmitted if a PDF symbol was detected but not decoded, and “NR” if no PDF symbol is detected and a 1D bar code was not decoded. Prefixes and suffixes enabled are appended around this message.

<FN3>1020101

<FN3>1020100

Transmit “No Decode” Message

Do Not Transmit “No Decode” Message

5-30

Page 80

Programming the LS 4800

LRC Checksum Enabling this option allows for appending an LRC checksum character at the end of a decode transmission. When an LRC checksum is enabled, the format of output data is as follows: <STX> <DATA...> <ETX> <LRC>. If <DATA...> contains the special characters STX, ETX, and DLE, a DLE character is used as an escape character and is added before each of those characters so that the receiving side knows not to interpret the special characters in the data as control characters. The LRC character is the exclusive OR of all characters except for the LRC character itself.

<FN3>1040401 Enable LRC Checksum

<FN3>1040400 Disable LRC Checksum

5-31