For the Symbol LS-3070

Page 72

LS 3070 Product Reference Guide: Programming

Data Transmission Formats Magstripe Data Transmission Format Magstripe data format options are open for user determination with the specific application. The following are standard selections: • Standard: <data as on card> • Option 1:

<acct nr>

• Option 2:

<acct nr> <SUFFIX>

• Option 3:

<acct nr> <SUFFIX> <exp data (MMYY)> <SUFFIX>

• Option 4:

<acct nr> <SUFFIX> <exp data (YYMM)> <SUFFIX>

• Option 5:

<acct nr> <SUFFIX> <name> <SUFFIX>

• Option 6:

<acct nr> <SUFFIX> <exp data (MMYY)> <SUFFIX> <name> <SUFFIX>

• Option 7:

<acct nr> <SUFFIX> <exp data (YYMM)> <SUFFIX> <name> <SUFFIX>

• Option 8:

<PREFIX> <acct nr>

• Option 9:

<PREFIX> <acct nr> <SUFFIX>

• Option 10:

<PREFIX> <acct nr> <SUFFIX> <exp data (MMYY)> <SUFFIX>

• Option 11:

<PREFIX> <acct nr> <SUFFIX> <exp data (YYMM)> <SUFFIX>

• Option 12:

<PREFIX> <acct nr> <SUFFIX> <name> <SUFFIX>

• Option 13:

<PREFIX> <acct nr> <SUFFIX> <exp data (MMYY)> <SUFFIX> <name> <SUFFIX>

• Option 14:

<PREFIX> <acct nr> <SUFFIX> <exp data (YYMM)> <SUFFIX><name> <SUFFIX>

<acct nr> = account number on card <exp data> = expiration date (MMYY = month, year; YYMM = year, month) <PREFIX> <SUFFIX> as selected by user

6-9

Page 73

LS 3070 Product Reference Guide: Programming

Scan Data Transmission Format Scan data format options can be selected by the user. The following are standard selections: • Standard:

<data as is>

• Option 1:

<data> <SUFFIX>

• Option 2:

<PREFIX> <data> <SUFFIX>

• Option 3:

<PREFIX> <data>

<data as is> = scanned bar code data <PREFIX> and <SUFFIX> as selected by the user

Laser Control Laser On Timeout The maximum time the laser will remain on or decode processing will continue during a trigger pull. Programmable in .5 sec increments from 0.5 to 6.0 sec.

6-10

Page 74

LS 3070 Product Reference Guide: Programming

RS-232C Options Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

Parity A parity check bit is the most significant bit of each ASCII coded character. If you select ODD parity, the parity bit will have a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. If you select EVEN parity, the parity bit will have a value 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. Select MARK parity and the parity bit will always be 1. Select SPACE parity and the parity bit is always 0. Select the parity type according to host device requirements.

Check Parity Select whether or not the parity of received characters is checked. The type of parity can be selected with the PARITY parameter.

Hardware Handshaking Hardware handshaking allows you to check the readiness of the receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is needed to prevent loss of transmitted data. Hardware handshaking may not be used in conjunction with software handshaking. Refer to the flowchart on the following page. RS-232C communications are designed to operate either with or without hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send. If RTS/CTS handshaking is selected, scan data is transmitted with the following sequence: (Note that the DTR signal is hardwired active.) • The base station reads the CTS line for activity. If CTS is asserted, the base will wait up to one second for the host to negate the CTS line. If, after one second the CTS line is still asserted, the base will sound a transmit error and any scanned data will be lost. 6-11

Page 75

LS 3070 Product Reference Guide: Programming

• When the CTS line is negated, the base asserts the RTS line and waits for one second for the host to assert CTS. When the host asserts CTS, data is transmitted. • When data transmission is complete, the base will negate RTS 10 msec after sending the last character. • The host should respond by negating CTS. The base will check for a negated CTS upon the next transmission of data. During the transmission of data, the CTS line should be asserted. • If the above communications sequence should fail, the base station will issue a transmit error. In this case, the data is lost and must be rescanned. Select whether the scan data is to be transmitted as soon as it is available or whether transmission follows the RTS/CTS procedure.

HARDWARE HANDSHAKING

SYMBOL IS DECODED

RTS AND CTS SELECTED?

NO REPONSE. AFTER 2 SECONDS, THE UNIT BEEPS 4 TIMES TO INDICATE A TRANSMISSION ERROR.

YES

NO

YES CTS ASSERTED?

If still asserted after 1 sec., indicate transmission error. ASSERT RTS

NO NO If not asserted after 1 sec., indicate transmission error.

CTS ASSERTED?

YES TRANSMIT DATA

FINISHED

6-12

Page 76

LS 3070 Product Reference Guide: Programming

Software Handshaking This parameter offers control of the data transmission process. It may be used instead of, but not in conjunction with, hardware handshaking. The base station also provides four software handshaking options: NONE, ENQ, ACK/ NAK, and ACK/NAK with ENQ. These options may be combined, for example ACK/NAK with ENQ. Refer to the chart following the parameter description.

No Software Handshaking ACK/NAK Only The ACK/NAK option checks the success or failure of transmission. The base station expects one of the following host responses after a data transmission: • <ACK> - Acknowledges a valid and successful transmission. • <NAK> - Indicates a problem with the transmission.

Whenever a <NAK> is received, the unit retransmits the same data and awaits an ACK/NAK response. After three unsuccessful attempts to transmit the same data, the base aborts any further communication attempts on that message. Transmission error is indicated by the unit sounding 4 short beeps. When no response for the duration of the serial response time-out parameter (default 2 seconds), or a NAK is received, the base station will retransmit the data until an ACK is received, or the third transmit failure. After three unsuccessful transmission attempts, the unit will abort any further communication attempts on the current message. It indicates this by sounding 4 long (1 second) beeps.

ENQ ONLY The ENQ option needs the host to request data before it is transmitted to the host. This ensures that data transmission occurs only when the host is ready to receive.

6-13

Page 77

LS 3070 Product Reference Guide: Programming

When you select the wait for ENQ option, the base station waits for an ENQ, Enquire character, from the host before it transmits data; otherwise the unit transmits data without waiting for an ENQ character from the host. With ENQ enabled, the base station must receive an ENQ from the host within a 2 second period after the last activity or 4 short beeps are sounded to indicate a transmission error; the unit is now ready to scan again.

ACK/NAK with ENQ This combines both handshaking options.

SYMBOL IS DECODED

SOFTWARE HANDSHAKING ENQ SWITCH ON?

NO REPONSE. AFTER 2 SECONDS, THE UNIT BEEPS 4 TIMES TO INDICATE A TRANSMISSION ERROR.

YES

NO

WAIT FOR ENQ CHARACTER TO BE RECEIVED FROM HOST

DATA IS TRANSMITTED.

ACK/NAK SWITCH ON?

YES WAIT FOR ACK OR NAK RESPONSE FROM HOST

ACK RESPONSE?

NO

YES

TRY 3 TIMES?

NO

YES, 4 LONG BEEPS

6-14

NO REPONSE. AFTER 2 SECONDS, THE UNIT BEEPS 4 TIMES TO INDICATE A TRANSMISSION ERROR.

FINISHED

NO

Page 78

LS 3070 Product Reference Guide: Programming

Serial Response Timeout This parameter determines the maximum period allowed to elapse before the base station assumes end of transmission. The delay period can range from 0 to 9.9 seconds.

Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

ASCII Format When enabled, this parameter transmits data in an 8-bit ASCII format. This allows the base station to interface with devices requiring that protocol. The default is 7-bit ASCII.

RTS Line State In order to transmit, some hosts expect the RTS line to be in a certain state (High or Low) when there is no hardware handshaking. This parameter will adjust the RTS Line State.

6-15

Page 79

LS 3070 Product Reference Guide: Programming

Intercharacter Delay Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 msec delay between the transmission of each character.

Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. If a prefix is selected, the code ID character is sent after the prefix. Code ID characters are: A = UPC-A, UPC-E, EAN-13, or EAN-8; B - Code 39; C = Codabar; D = Code 128; F = Interleaved 2 of 5; G = Discrete 2 of 5.

Transmit AIM ID Character Enabling this parameter, with the Transmit Code ID Character parameter enabled allows you to send the AIM code identifer in lieu of the Symbol identifiers listed above. The identifier will be sent as a three character prefix, in accordance with AIM specifications for symbology identifiers. See AIM’s Guidelines on Symbology Identifiers for full details.

Ignore Unknown Characters When enabled, all data is sent except for unknown characters, and no error beeps are sounded. Unknown characters are those characters the selected terminal does not recognize. When disabled, all data containing one or more unknown characters is discarded, and error beeps are sounded.

OCIA Clock Polarity Selects the appropriate clock edge values so that a host terminal with nonstandard OCIA format can recognize the clock signal phase synchronized with data.

6-16