Page 64

Chapter 6 Programming Programming Overview Before programming, follow the instructions in the Chapter 2: Setup and Chapter 5: Interface Guide. Programming occurs through use of bar code menus. Not all parameters, however, apply to your specific host. For example, if you have an OCIA terminal, RS-232C parameters such as baud rate and parity will not apply. Simply ignore those parameters not designed for your application. If you're not sure which parameters apply, refer to the Parameter Selections on page 6-21 for your specific terminal type. The first section of this chapter, Parameter Descriptions beginning on page 6-3, defines parameters and the bar codes necessary to set those parameters. To customize data for your specific needs, see the Advanced Programmer’s Guide. Consult the Parameter Descriptions beginning on page 6-3 for explanations of parameter types; Parameter Selections beginning on page 6-21 shows the available parameters for various terminal types. If the default values suit your requirements, all you need to do is scan the SET DEFAULT bar code. Parameters other than default values can be set by scanning sequences of bar codes. Chapter 7: Parameter Menus contain all the bar codes necessary to program the scanner for each parameter selection.

6-1

Page 65

LS 3070 Product Reference Guide: Programming

Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter. For example, if you want to set the baud rate to 9600, simply scan the 9600 bar code listed under Baud Rate. The base station will issue a warble tone, signifying a successful parameter entry. If you want to add or change prefixes and suffixes or customize the data transmission format, you will have to scan several bar codes. This procedure is described in Parameter Descriptions beginning on page 6-3.

Errors While Scanning Don't worry if you make an error during a scanning sequence. Merely reenter the correct parameter.

6-2

Page 66

LS 3070 Product Reference Guide: Programming

Parameter Descriptions Set Parameter Defaults Scanning the SET DEFAULT bar code returns all parameters to the values listed in the Default Table beginning on page 6-28.

Host Interface Code Each Interface Cable Assembly defaults to a given host. These assemblies, their corresponding defaults, and additional bar codes begin in Chapter 7: Parameter Menus. In some cases, two bar codes may correspond to one interface type; this happens when different software revisions exist for the same host type. If there are two bar codes for your host type, try the first bar code; if that does not work, then try the second one.

Code Types The bar code menu selections enable the scanner to decode any or all of the following symbologies. • UPC Versions A and E (EAN 8 and 13)

• Codabar

• Code 39

• Code 39 Full ASCII

• Discrete 2 of 5

• Interleaved 2 of 5

• Code 128

• MSI Plessey

• EAN 128

The scanner will autodiscriminate between all of the above symbologies, except for Code 39 and Code 39 Full ASCII.

Code Lengths Code lengths for certain code type (i.e., Code 39, Codabar, etc.) may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 39 characters containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). 6-3

Page 67

LS 3070 Product Reference Guide: Programming

One Discrete Length - This option will allow you to decode only those codes containing a selected length. For example, if you select D 2 of 5 One Discrete Length, then scan 1, 4, the only D 2 of 5 codes decoded will be those containing 14 characters Two Discrete Lengths - This option will allow you to decode only those codes containing two selected lengths. For example, if you select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only D 2 of 5 codes decoded will be those containing 2 or 14 characters. Any Length - Scanning this option allows you to decode the selected code type containing any number of characters. For example, if you scan Codabar Any Length, you will be able to decode a Codabar symbol containing any number of characters.

Code 39 Full ASCII The ASCII character set assigns a code for letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code control character ($ + % /) preceding a Code 39 symbol and assigns an ASCII character value. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it will be interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. The LS 3070 will not autodiscriminate between Code 39 and Code 39 Full ASCII.

6-4

Page 68

LS 3070 Product Reference Guide: Programming

Decode Options Transmit UPC-E/UPC-A Check Digit Select if decoded UPC symbols are transmitted with or without a check digit.

Convert UPC-E To UPC-A Use this parameter to convert UPC-E (zero suppressed) decoded data to UPCA format before transmission. After conversion, data will follow UPC format and be affected by UPC-A programming selections (e.g., Preamble, Check Digit).

Ean Zero Extend This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.

Xmit “No Decode” Message This feature gives you the option to transmit “NR” when a symbol does not decode. Prefixes and suffixes enabled will be appended around this message.

Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters. Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/ EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LS 3070 will, after additional processing to ensure a good decode, transmit either. (NOTE: To minimize the risk of invalid data transmission, it is recommended that you select whether to read or ignore supplemental characters.)

6-5

Page 69

LS 3070 Product Reference Guide: Programming

Code 39 Check Digit When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with a modulo 43 check digit algorithm.

ITF-14/EAN-13 Conversion If your terminal supports EAN-13, this feature converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length (either LENGTH 1 or LENGTH 2) must be set to 14, the code must have a leading zero and a valid EAN-13 check digit.

Bi-Directional Redundancy for Codabar This parameter applies only to Codabar symbols. When enabled, the bar code must be decoded in both directions to be considered good.

MSI Plessey Check Digit One or two digits at the end of the bar code that check the integrity of the data. At least one check digit (default) is always required. Check digits are not transmitted with the data.

Code 39 Buffering (Scan & Store) When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See Code 39 Buffering beginning on page 6-26 for further details. When the scan and transmit option is selected, decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer. Scan and Store affects Code 39 decodes only. If you select scan and store, it is recommended that you configure the scanner to decode Code 39 symbology only.

6-6

Page 70

LS 3070 Product Reference Guide: Programming

Beeper Volume Select degree of volume, high or low.

Beep After Good Decode Determine if the unit beeper will sound during normal scanning. Usually it is desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. See Beeper Definitions beginning on page 6-24.

UPC/EAN Security Level The LS 3070 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application. • Security Level 0 - This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in spec” UPC/EAN bar codes. • Security Level 1 - As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the misdecodes are limited to these characters, select this security level. • Security Level 2 - If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7 and 8, select this security level. • Security Level 3 - If you have tried Security Level 2, and are still experiencing mis-decodes, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level will significantly impair the decoding ability of the scanner.

6-7

Page 71

LS 3070 Product Reference Guide: Programming

Decode Redundancy Use this parameter to indicate whether the scanner must read a bar code one time (LEVEL 1), two times (LEVEL 2), or three times (LEVEL 3) before decoding it. A higher level of redundancy ensures the accuracy of a decode in, for example, poor quality symbols.

UPC-A and -E Preamble Three options are given for the lead-in characters of decoded UPC-A or UPCE symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble

The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.

Pause Duration This parameter, used in data editing, allows a pause to be inserted at any point in the data transmission. Pauses are set by scanning a two digit number (i.e., two bar codes), and are measured in 1/10 second intervals. For example, scanning bar codes “0” and “1” will insert a 1/10 second pause; “0” and “5” will give you a 1/2 second delay.

Prefix/Suffix Values A prefix/suffix may be appended to scan and magstripe data, for use in data editing. These values are set by scanning a four digit number (i.e., four bar codes) that correspond to keycodes for various terminals. See the ASCII Table beginning on page 8-1.

6-8