Page 41
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Decode Options (Contd) Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single-character prefix already selected, the code ID character is appended as a prefix to the decode. Code ID characters are: A = UPC-A, UPC-E, EAN-13, or EAN-8; B = Code 39; C = Codabar; D = Code 128; E = Code 93; F = Interleaved 2 of 5; G = Discrete 2 of 5 or Discrete 2 of 5 IATA. Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller.
EAN Zero Extend This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller, unless data is being sent as Code 39.
CLSI Editing Use this parameter to insert a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. The symbol length does not include start and stop characters. Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller, unless data is being sent as Code 39.
NOTIS Editing This option strips the start and stop characters from decoded Codabar symbols. Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller, unless data is being sent as Code 39.
P10
Page 42
LS 3064MX PROGRAMMER’S GUIDE
• UPC A And UPC-E Preamble Three options are given for the lead-in characters of decoded UPC-A or UPC-E symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it can not be transmitted without the system character. Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller, unless data is being sent as Code 39.
• Baud Rate Baud rate is the number of bits of data transmitted per second. The unit's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form. Note: This option is only valid when scanning or downloading to an RS-232C host.
• Data Bits This parameter allows you to send data in 7-bit or 8-bit format. Note: This option is only valid when scanning or downloading to an RS-232C host.
P11
Page 43
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Parity A parity check bit is the most significant bit of each ASCII coded character. If you select ODD parity, the parity bit will have a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. If you select EVEN parity, the parity bit will have a value 0 or 1 to ensure that an even number of 1 bits are contained in the coded character. Select MARK parity and the parity bit will always be 1. Select SPACE parity and the parity bit will always be 0. Select the parity type according to host device requirements.Note: This option is only valid when scanning or downloading to an RS232C host.
• Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements. Note: This option is only valid when scanning or downloading to an RS-232C host.
• DTR Polarity DTR polarity allows the user to set the DTR line polarity of the RS-232C port. The user selects a high or low polarity, depending on the host configuration.
• Check Parity Select whether the parity of received characters is checked or a parity check is run on each character of received data. The type of parity used is selectable through the PARITY parameter. Note: This option is only valid when scanning or downloading to an RS-232C host.
P12
Page 44
LS 3064MX PROGRAMMER’S GUIDE
• Communications Protocol Hardware Handshaking Hardware handshaking allows you to check the readiness of the receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is needed to prevent loss of transmitted data. The data interface consists of an RS-232C port. See Scanner/RS-232C Interface on pages 19-20 in the Users Guide. The port has been designed to operate either with or without hardware handshaking lines, RTS (Request To Send), and CTS (Clear To Send). If RTS/CTS handshaking has not been selected, scan data will be transmitted as it becomes available. If optional RTS/CTS handshaking has been selected, the unit proceeds as follows: • Examine CTS. If CTS is not asserted by the host, RTS will be asserted by the scanner. If CTS is asserted by the host, the scanner will wait up to 1 second for CTS to be negated. • When the host asserts CTS in response to, and within 1 second of, the scanner’s RTS, data will be transmitted. • When data transmission is complete, the scanner will negate RTS 10 ms after sending the last character. • The host should respond by negating CTS. The scanner will not wait for this negation, but rather will check before the next transmission, as above. • If the above communication attempt should fail for any reason, the scanner will issue an error beep to alert the operator that the data was not successfully transmitted. In this case, the data is lost and must be rescanned.
P13
Page 45
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Communications Protocol (Contd) Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. These options may be combined, for example ACK/NAK with ENQ. Note: This option is only valid when scanning or downloading to an RS-232C host. 1. No Software Handshaking 2. ACK/NAK Only The ACK/NAK option checks the success or failure of transmission. The scanner expects one of the following host responses after a data transmission: <ACK> - Acknowledges a valid and successful transmission. <NAK> - Indicates a problem with the transmission. Whenever a <NAK> is received, the unit retransmits the same data and awaits an ACK/NAK response. After three unsuccessful attempts to transmit the same data, the scanner aborts any further communication attempts on that message. Transmission error is indicated by the unit sounding 4 long beeps. 3. ENQ ONLY The ENQ option needs the host to request data before it is transmitted to the host. This ensures that data transmission occurs only when the host is ready to receive. When you select the wait for ENQ option, the scanner waits for an ENQ, Enquire, character from the host before it transmits data; otherwise, the unit transmits data without waiting for an ENQ character from the host. With ENQ enabled, the scanner must receive an ENQ from the host within a 2-second period after the last activity or 4 long beeps are sounded to indicate a transmission error; the unit is now ready to scan again. 4. ACK/NAK with ENQ This combines both handshaking options. P14
Page 46
LS 3064MX PROGRAMMER’S GUIDE
HARDWARE HANDSHAKING
SYMBOL IS DECODED
NO
RTS/CTS HANDSHAKING ENABLED
YES WAIT UP TO 1 SECOND FOR CTS TO BE NEGATED
NO
CTS NEGATED
YES SCANNER ASSERTS RTS - WAIT UP TO 1 SECOND FOR HOST TO ASSERT CTS
NO CTS ASSERTED
YES SOFTWARE HANDSHAKING
NO
ENQ ENABLED
YES WAIT UP TO 2 SECONDS FOR ENQ FROM HOST
NO
ENQ RECEIVED
YES DATA IS TRANSMITTED
NO
ACK/NAK ENABLED
YES SCANNER WAITS FOR ACK/NAK FROM HOST
YES
ACK RECIEVED
NO NO
TRY 3 TIMES?
YES TRANSMISSION ERROR SCANNER BEEPS 4 TIMES FINISHED
LS 3064MX Hardware and Software Handshaking Sequence P15
Page 47
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Prefix The scanner will add one of the following start-of-text characters to transmitted data: • None • Start-of-text <STX> • One user-defined prefix (can be any ASCII character). Note: This option is only valid when scanning or downloading to an RS-232C host.
• Suffix Select one or two end-of-text characters to be added to transmitted data: • None • CR (Carriage Return) - Returns the cursor to the same position on the line after each decode. • LF (Line Feed) - Moves the cursor down a line after each decode. • CR & LF - Selecting both CR & LF returns the cursor to the first position on successive lines after each decode. • One or two characters, user-defined. Note: This option is only valid when scanning or downloading to an RS-232C host.
• Communications Delays And Time-outs (Intercharacter Delay) Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 msec delay between the transmission of each character. Note: This option is only valid when scanning or downloading to an RS-232C host.
P16
Page 48
LS 3064MX PROGRAMMER’S GUIDE
• Transmission Mode Data can be transmitted in normal mode using either RS-232C, or by attaching the LS 3064MX to the SCANNER port of an interface controller. When downloading, stored data can be transmitted via scanner emulation to the attached interface controller.
• Format Options Note that Append Serial Number/Append User ID options are downloaded as Code 39 when downloading via scanner port. The interface controller must have Code 39 decode capability.
Append Serial Number This parameter relates each scanner to a specific batch of downloaded data. When enabled, a string in the form: SOD#YYMMDDHHMMSS#XXXXXXXX precedes the data block, and a string in the form EOD#XXXXXXXX follows the data block. If download of data is interrupted, scanning DOWNLOAD FROM CURRENT POINT (see menu on page OP5) appends a string in the form COD#YYMMDDHHMMSS#XXXXXXXX. where: SOD = start of data EOD = end of data COD = continuation of data YYMMDDHHMMSS (Real-time clock time/date stamping) are year, month, day, hour, minute, and second. Output will be determined by Time/Date options enabled. XXXXXXXX is the scanner serial number # = space If the scanner beeps 5 times on decoding any symbol, the serial number must be set. See the following page for details of how to reset the serial number. P17
Page 49
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Format Options (Contd) Append User ID When enabled, this parameter allows data being downloaded to be preceded by a user-selectable header relating data to a user or specific location. The ID is in the form: H#XXXXXX... where: XXXX... is selected User ID up to 20 characters # = space The User ID is sent at the start of data and after a terminating string (if used). To select to send a User ID, scan APPEND USER ID , ENABLE , and ENTER .
Select User ID To select a User ID, scan SELECT USER ID then the selected symbol. If a User ID is not selected after APPEND USER ID is enabled, then a string consisting of eight X's will be sent as the User ID. If APPEND SERIAL NUMBER is also enabled, this string will be sent after the start of data string.
• Set Serial Number Five long low beeps on scanning any symbol indicates that the scanner has “lost” its pre-programmed serial number. Reset the serial number by scanning SET SERIAL NUMBER , and then the copy of the serial number enclosed in the scanner's packing box, or by scanning ENTER SERIAL NUMBER , then scanning one by one the digits or characters of the serial number shown on the label of the scanner’s handle, and then the END SERIAL NUMBER bar code.
P18
Page 50
LS 3064MX PROGRAMMER’S GUIDE
• Abort Procedure In the event of a communications error, the LS 3064MX will either: • Abort download or • Ignore the communications error and skip to next symbol stored in memory. When download is aborted, the scanner will give a double beep every 2 seconds. On the next trigger pull a hi/hi/lo/lo beep is issued. If you are using the abort download option, recover by scanning the SKIP TO NEXT BAR CODE followed by the DOWNLOAD FROM CURRENT POINT symbol.
• Quantity Field The buffer must be empty before programming the scanner for this parameter. When enabled, the LS 3064MX looks back through the last 100 decodes for a match. If an identical item is found, the associated quantity is increased by one. This parameter also allows the user to scan in a quantity. The quantity field may range from 0 to 9999. After scanning a bar code, scan up to 4 bar codes to represent the quantity. You will hear a short, low-high tone after scanning each symbol.
• Transmit Quantity Two format options are available: Option 1 The LS 3064MX downloads a decode n times, where n is a quantity. Option 2 The quantity is transmitted in the form Data Qn where: n is a 4-digit quantity in the range 0-9999, and data is the value of the decode. Note: If Option 2 is selected and data is being sent via the scanner port, the data is sent as Code 39. P19