For the Symbol LS-3064

Page 31

Table of Contents Programming the LS 3064MX

P1-P2

Parameter Selections

P3-P6

Parameter Descriptions

P7-P22

Parameter Menus

P23-P94

ASCII Table

P95

Page 32

LS 3064MX PROGRAMMER’S GUIDE

Programming the LS 3064MX This section of the PRODUCT REFERENCE GUIDE consists of a Programmer's Guide and an Operating Guide. The Programmer's Guide has all the bar codes necessary for programming the scanner. The Operating Guide begins on page OP1, and contains the bar codes necessary to initiate Normal, Store, and Download modeIntelliStands. Before programming, follow the Set Up instructions on page 4 of the USER'S GUIDE. Consult the Parameter Descriptions section for explanations of parameter type; Parameter Menus contain all the bar codes necessary for programming. The Parameter Selections table on pages P3-P6 lists all selectable parameters and their default values. Before programming the LS 3064MX, scan the SET DEFAULT bar code to reestablish the factory settings. If all the default values (including the data download mode) suit your requirements, no further programming is necessary. Program the scanner for parameters other than default values by scanning sequences of bar codes. A scanning sequence establishes a value for one parameter type; this value is retained in non-volatile memory. During a scanning sequence, you scan bar codes for a parameter type, a parameter value, and ENTER .

P1

Page 33

LS 3064MX PROGRAMMER’S GUIDE

Programming the LS 3064MX Scanning Sequence Example Suppose you want to program the scanner for all default settings except for BAUD RATE . Since most of the default settings are suitable for your application, scan the SET DEFAULT bar code. The default for BAUD RATE is 9600 - you need it set for 4800 . Scan the three bar codes in the order listed below: Scan 1. BAUD RATE 2. 4800 3. ENTER

You will hear... Short high tone Short high tone Hi/Lo/Hi/Lo warble

After the last scan in a successful scanning sequence (ENTER ), the warble sound (i.e., hi/lo/hi/lo) indicates that the LS 3064MX has been successfully programmed for the selected parameter. Other beeper indications are listed on pages OP10-OP12

P2

Page 34

LS 3064MX PROGRAMMER’S GUIDE

Parameter Selections Parameter

Options

Default

Code Types

Code 39, Discrete 2 of 5, All Codes Code 93, Codabar, UPC/EAN, Interleaved 2 of 5, Code 128, Code 39 Full ASCII, All codes (Note that code types must be compatible with the controller being used.) ScanStand Time-out

15 to 90 min in 15 min increments

60 min

Laser On Time

0.5 to 6 sec. in 0.5 sec. increments

3 sec.

First Length I 2 of 5

2 digit entry in range 01-50

10

Second Length I 2 of 5

2 digit entry in range 00-50

0

First Length D 2 of 5

2 digit entry in range 01-50

10

Second Length D 2 of 5

2 digit entry in range 00-50

0

Xmit UPC-E Check Digit

Enabled, Disabled

Enabled

Xmit UPC-A Check Digit

Enabled, Disabled

Enabled

Decode UPC/EAN Supplemental

With Supps, Without Supps, Autodiscriminate

Without Supps

Decode UPC only

Enabled, Disabled

Disabled

Convert UPC-E to A

Enabled, Disabled

Disabled

Convert all to C392,3

Enabled, Disabled

Disabled

Beep on good decode

Enabled, Disabled

Enabled

Percent Check

Enabled, Disabled

Enabled

P3

Page 35

LS 3064MX PROGRAMMER’S GUIDE

Parameter Selections Parameter

Options

Default

Xmit “No Decode” Character

Enabled, Disabled

Disabled

Xmit Code ID Character

Enabled, Disabled

Disabled

EAN Zero Extend

Enabled, Disabled

Disabled

CLSI Editing

Enabled, Disabled

Disabled

NOTIS Editing

Enabled, Disabled

Disabled

UPC-E Preamble

System Character, System Character & Country Code, None

System Character

UPC-A Preamble

System Character, System Character & Country Code, None

System Character

Baud Rate

300, 600, 1200, 2400, 4800, 9600, 19,200

9600

Data Bits

Seven, Eight

Seven

Parity

Even, Odd, Mark, Space, None

Even

Number of Stop Bits

One, Two

Two

DTR Polarity

High, Low

High

Check Parity of Received Data

Enabled, Disabled

Enabled

P4

Page 36

LS 3064MX PROGRAMMER’S GUIDE

Parameter

Options

Default

Hardware Handshaking

None, RTS/CTS

None

Prefix to Decoded Data

None, Start-of-text <STX>, Users Choice (1 selection)

None

Suffix to Decoded Data

None, CR, LF, CR/LF, Users Choice (1 selection), Users Choice (2 selections), Endof-text <ETX>.

CR/LF

Intercharacter Delay

00-99 ms

None

Transmit Modes

Transmit using scanner port, Transmit via RS-232

Transmit using scanner port

Append Serial Number

Enabled, Disabled

Disabled

Append User ID

Enabled, Disabled

Disabled

Select User ID2

Any alphanumeric string less than or equal to 20 characters

“xxxxxxxx”

Abort Procedure

Abort download, Ignore communications error and skip to next symbol

Abort download

Quantity Field

Enabled, Disabled

Disabled

Xmit Quantity

Transmit bar code data n times, Transmit bar code data and a quantity, n

Transmit bar code data n times

Software Handshaking

None, ENQ, ACK/NAK, ACK/NAK with ENQ

None

P5

Page 37

LS 3064MX PROGRAMMER’S GUIDE

Parameter Selections Parameter

Options

Default

Select Terminating String

None, any alpha/numeric string less than 30 characters

None

Terminating String Delay1

No delay, delay in range 00-99 sec, in 1 sec increments

10 sec

Interdecode Delay1

No delay, delay in range 00-99 (in .25 sec increments; actual delay range 00-25 sec)

No delay

Time-out in range 03..30 seconds Time-out in range 03..30 seconds

3 sec 3 sec

Low Battery Check

Enabled, Disabled

Enabled

Compress Mode

Enabled, Disabled

Disabled

Autodiscriminate Power Mode

Enabled, Disabled

Disabled

Symboless Scan Stand

Enabled, Disabled

Disabled

Append Date/Time

Append Date & Time, Append Date, Append Time, None

None

Stamp After First & Last Decode

Enabled, Disabled

Disabled

Transmit Retry Time-out Normal Mode Download Mode

1

Valid only when transmitting via scanner port or RS-232.

2

When using Code I28, Code 39 Full ASCII must be enabled or non-Code 39 characters will be replaced by blanks.

3

Valid only when transmitting via scanner port.

P6

Page 38

LS 3064MX PROGRAMMER’S GUIDE

Parameter Descriptions • Set Defaults Scanning the SET DEFAULTS bar code configures all parameters to the default values shown on pages P3-P6. You will hear a warble beep if the scanner was programmed successfully for the default values.

• Code Types The LS 3064MX can decode any combination of the following code types: • Code 39/Code 39 Full ASCII • Discrete 2 of 5

• Interleaved 2 of 5

• Code 93

• Code 128

• Codabar

• UPC-A, UPC-E, EAN-8, EAN-13

The default for this parameter is that the scanner can decode all of the above code types. Note that Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. (The default is Code 39.) If a 2 of 5 code type is enabled, an appropriate length must also be set.

• Fixed Lengths For Code 2 of 5 One or two lengths for Discrete and Interleaved 2 of 5 can be selected; default settings are 10 and 0 for each type. To decode a 2 of 5 symbol, the correct length for that symbol must be set. The range for length 1 is 01-50, and for length 2, 00-50.

• Scanstand Time-out In ScanStand operation, if the scanner is not used for a pre-determined length of time, the operation of the scanner will change. For ScanStands using a codabar symbol, after the selected time-out, the scanner will turn off. For IntelliStands, after the selected time-out, the blinking will reduce to a 5% duty cycle. Scanning a new symbol will return the scanner to a 25% duty cycle. The time-out ranges from 15 to 90 minutes in 15 minute increments. The default is 60 minutes.

P7

Page 39

LS 3064MX PROGRAMMER’S GUIDE

Parameter Descriptions • Laser On Time This parameter allows you to select a specific laser on time. Values range from 0.5 to 6 seconds in 0.5 second increments. The default is 3 seconds.

• Decode Options Transmit UPC-E/UPC-A Check Digit Select if decoded UPC-E or UPC-A symbols are transmitted with or without the check digit. Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller, unless data is being sent as Code 39.

Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters, or whether the scanner will autodiscriminate between the two. Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the scanner will, after additional processing to ensure a good decode, transmit either. If you are downloading through the scanner port, make sure the set-up for the attached controller corresponds to the LS 3064MX set up (to decode or not decode supplementals).

Decode UPC Only (Not EAN) If selected, this option limits LS 3064MX UPC/EAN decode capability to UPC versions only. It disables EAN decode capability.

P8

Page 40

LS 3064MX PROGRAMMER’S GUIDE

• Decode Options (Contd) Convert UPC-E to UPC-A Use this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data will follow UPC format and be affected by UPC programming selections (e.g., Preamble, Check Digit). Note: This option is not valid when scanning or downloading through the SCANNER port of an interface controller, unless data is being sent as Code 39.

Convert all to Code 39 Valid only when scanning or downloading via the scanner port of an interface controller. When enabled, all scan data is converted to Code 39 before being sent to the controller.

Beeper Enable/Disable Determine if the unit beeper will sound during normal scanning. Usually it is desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. Beeper indications are on pages OP10-OP12.

Percent Check In Store mode, with percent check enabled, the scanner sounds a hi/lo beep on good decode to signal that memory is 90% full. This beep replaces the normal short, high tone beep on good decode. If Percent Check is disabled, the normal high tone decode beep will sound regardless of memory status.

Xmit “No Decode” Character This feature allows you to transmit “NR” when a symbol does not decode. This option is only valid when the scanner is in normal mode. Also, if the unit is transmitting via RS-232, any prefixes and suffixes enabled will be appended around this string. If the unit is transmitting via the scanner port, the “NR” will be sent as a Code 39 symbol.

P9