LS 3064MX MEMORY SCANNER
Scanner/Controller Interface Scanner Emulation Mode The LS 3064MX intelligent scanner decodes symbols independent of an attached controller. The bar code data is then re-encoded and presented to the controller as scan data. PIN
SIGNAL NAME
FUNCTION
1
Start of Scan
This output from the scan head is used to synchronize the decode logic with the scan head. A high output simulates sweeping in one direction, and low simulates sweeping in the opposite direction. This is an open collector output capable of sinking 50 mA. The frequency of scans is approximately 36 scans per second.
2
Digitized Bar Pattern
Output from the scanner is electrically identical to pin 1, providing a series of pulses with widths proportional to the elements of the simulated bar code being scanned. A low output represents a bar, and a high output represents a space.The frequency of the pulses depends on the density of the symbol being scanned.
3
Decode LED/Beeper
This TTL level input is used to determine when the symbol data has been successfully decoded by the controller.
4
Not Used
17
Page 22
LS 3064MX MEMORY SCANNER
Scanner/Controller Interface PIN
SIGNAL NAME
FUNCTION
5
Trigger Switch
Electrically equivalent to pin 1, this output simulates trigger operation. (Low = pulled, Open = released)
6
Enable
This input, in response to the simulated trigger, serves to indicate to the LS 3064MX that the controller is requesting scan data.
7,8
Ground
This pin carries the current used by the scan head, and should be connected to a ground which can handle the full 170 mA load.
9
12 Volt Input
This input will provide power for scanner operation and battery trickle charging @ approximately 10 mA. It must be 9 to 14 volts at 130mA.
18
Page 23
LS 3064MX MEMORY SCANNER
Scanner/RS-232 Interface 25-Pin D-Type Connectors* PIN
SIGNAL NAME
FUNCTION
2
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
3
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
4
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
5
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.
6
DTR
Data Terminal Ready. This signal is normally high, but can be programmed low.
7
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
*Available in both male and female configurations. Consult the Product Ordering Guide for part numbers.
19
Page 24
LS 3064MX MEMORY SCANNER
Scanner/RS-232 Interface 25-Pin D-Type Connectors* PIN
SIGNAL NAME
FUNCTION
2
TxD
Serial data transmit output. It will drive the serial data receive input on the device communicating with the scanner.
3
RxD
Serial data receive input. It will be driven by the serial data transmit output on the device communicating with the scanner.
4
RTS
Request-to-send handshaking output line. It may be optionally used by the scanner to signal another device that data is available to send. It can only be used in conjunction with the CTS line.
5
CTS
Clear-to-send handshaking input line. It may be optionally used by another device to signal the scanner that it may commence transmitting data. It can be used only in conjunction with the RTS line.
7
GROUND
Power supply input ground pin and reference for both output signals. It must be capable of sinking all return current.
20
DTR
Data Terminal Ready. This signal is normally high, but can be programmed low.
*Available in both male and female configurations. Consult the Product Ordering Guide for part numbers.
20
Page 25
LS 3064MX MEMORY SCANNER
Technical Specifications ITEM Power Requirements: External Supply Voltage Operating Current
DESCRIPTION 9 to 14 VDC, 12 VDC typical 130 mA typical scanning 60 mA typical transmitting or standby 12 mA typical idling with trickle charge
Trickle Charge Current
12 mA typical, 17 mA max @12 VDC
Power Requirements: Portable Battery Voltage Operating Current Power Down Current:
5.5 to 7.5 VDC (5 NiCad batteries) 120 mA typical scanning 5 µA typical, 8µA max
NiCad Recharge Time Installed in Scanner
When Removed
Half charge: 24 hrs; approx. 10,000 1/2 second scans Full charge: 48 hrs; approx. 20,000 1/2 second scans Half charge: 3 to 4 hrs; approx. 10,000 1/2 second scans Full charge: 7 to 8 hrs; approx. 20,000 1/2 second scans
NiCad Batteries
Under normal conditions, more than 1000 charge/ discharge cycles can be expected.
On-Board Memory
32 Kilobytes
Memory Backup
Lithium Battery: 3.0V @ 250 mAh Life: typically 8 years
Scan Repetition Rate
Approximately 36 (± 3) scans/sec (bidirectional)
Skew Tolerance
± 10˚ for 7.5 mil symbol at 2 in.
Pitch Angle
± 65˚ for 20 mil symbol at 10 in.
21
Page 26
LS 3064MX MEMORY SCANNER
Technical Specifications ITEM
DESCRIPTION
Decode Depth of Field
Max typical working distance is 35 in. (89 cm) for 55 mil symbols; minimum element width resolution is 5.0 mils
Print Contrast Minimum
25% absolute dark/light reflectance differential, measured at 675 nm
Ambient Light Immunity
Immune to direct exposure from office-level lighting and to direct exposure from sunlight
Durability
6-ft. drop to concrete
Operating Temperature
32° to 104°F
0° to 40°C
Storage Temperature
-40° to 140°F
-40° to 60°C
Coil Cable Length
8 ft.
244 cm
Height
6.9 in.
17.5 cm
Length
4.9 in.
12.4 cm
Width
2.8 in.
7.1 cm
Weight
.825 lb.
.377 kg
22
Page 27
LS 3064MX MEMORY SCANNER
Scanner Labeling - CDRH Class 2 LS 3064MX scanners use a low-power, visible laser. As with any very bright light source, such as the sun, the user should avoid staring directly into the light beam. Momentary exposure to a CDRH Class II laser is not known to be harmful. Required safety label as it appears on the scanner.
C A U T I O N LASER LIGHT - DO NOT STARE INTO BEAM. 1.0 mW MAXIMUM POWER LASER DIODE - 680 nm WAVELENGTH CLASS II LASER PRODUCT symbol technologies, inc. bohemia n.y. u.s.a. made in u.s.a.
MOD NO. SER NO. MFD
R COMPLIES WITH 21 CFR 1040 & IEC 825 COVERED BY U.S. & FOREIGN PATENTS DANGER - LASER LIGHT WHEN OPEN, AVOID DIRECT EXPOSURE TO BEAM
CAUTION : Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous visible light exposure.
23
Page 28
LS 3064MX MEMORY SCANNER
Scanner Labeling - IEC 825 Class 1 LS 3064MX scanners use a low-power visible laser. The scanner is designed for laser safety according to IEC 825 Class 1. Class 1 laser products are inherently safe. Exposure to the laser beam will cause no harm to your eyes or skin.
LASERKLASSE ZEITBASIS 1000 SEKUNDEN LASER ABTASTER VON STRICHCODE
LASER CLASS I AS PER BS7192 TIME BASIS 1000 SECONDS BARCODE DATA CAPTURE
LASER DE CLASSE I SELON CEI 825 BASE DE TEMPS 1000 SECONDES LECTEUR DE CODE A BARRES symbol technologies, inc. bohemia n.y. u.s.a. made in u.s.a.
MOD NO. SER NO. MFD
COMPLIES WITH 21 CFR 1040 & IEC 825 COVERED BY U.S. & FOREIGN PATENTS
CAUTION : Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous visible light exposure.
24
Page 29
LS 3064MX MEMORY SCANNER
Scanner Labeling - IEC 825 Class 2 LS 3064MX scanners use a low-power, visible laser. As with any very bright light source, such as the sun, the user should avoid staring directly into the light beam. Momentary exposure to a IEC 825 Class II laser is not known to be harmful. Required safety label as it appears on the scanner.
ACHTUNG LASERSTRAHL, LASERKLASSE 2, NICHT IN DEN STRAHL BLICKEN. LUMIERE LASER - NE PAS REGARDER DANS LE FAISCEAU APPARIEL A LASER DE CLASSE 2. CAUTION-LASER LIGHT. DO NOT STARE INTO BEAM. IEC CLASS 2 LASER PRODUCT 680 NM, 1.0 MW LASER symbol technologies inc.
bohemia n.y. u.s.a.
model no.
serial no.
VOLTAGE/CURRENT
CAUTION : Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous visible light exposure.
25
Page 30
LS 3064MX MEMORY SCANNERS
LS 3064MX Programmer’s Guide