Page 51
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Terminating String This parameter allows selection of a bar code that will indicate the end of a block of data. To establish a terminating string, scan the select terminating string symbol and then scan the bar code to be used as the terminating string.
• Terminating String Delay When data has been downloaded, a user-selectable terminating string delay will occur after the selected terminating string has been sent, i.e., before the next block of data is sent. The delay can be in the range of 00-99 seconds.
• Interdecode Delay This parameter is used to select the delay inserted between each decode in download mode. It does not affect other modes of operation. The user selects a value in the range 00-99, where each increment is a .25 second delay (i.e., delay ranges from 00~25 seconds).
• Transmit Retry Time-out (Normal Mode/Download Mode) This parameter indicates how long the LS3064 will try to send data if no response is received from the attached console. It allows you to change the time-out delay in normal or download mode when data is being transmitted via scanner emulation. The delay can range from 03-30 seconds. If you scan 00, 01, or 02 seconds, the unit defaults to 03 seconds.
• Low Battery Check If this parameter is enabled, the scanner will indicate when the battery is low by the Low Battery Check beep sequence (hi hi hi lo). When this sequence sounds, the battery should be recharged.
P20
Page 52
LS 3064MX PROGRAMMER’S GUIDE
• Data Compression If Compress Mode is enabled, numeric data is stored in approximately half the space needed for non-compressed data. Data from alphanumeric bar codes will be stored in ASCII as is. Compressed data will be sent as Code 39 when downloading via the SCANNER port.
• Autodiscriminate Power Mode When Autodiscriminate Power Mode is enabled, upon power-up the scanner will enter one of the following modes: • Storage Mode if no external power is detected; • Normal Mode if external power is connected and the storage buffer is empty (there is no data to download); • Download Mode if external power is connected and there is data in the buffer. (The user must pull the trigger to begin download.) If this parameter is disabled, the user must program the scanner by scanning the bar codes on pages OP4-OP5.
• IntelliStand Options This option prevents the scanner from switching to battery if power to the host is turned off, thereby conserving battery power. When disabled, you cannot enter IntelliStand mode while using battery power. Enable this option to use the IntelliStand while the scanner is operating using battery power, and in the Storage Mode.
• Date And Time Options When enabled, date and time are appended to all scan data while the LS 3064MX is in store or normal modes. The default for this parameter is no date/time stamping. Note: Buffered data subsequently downloaded via the controller SCANNER port is sent as Code 39.
P21
Page 53
LS 3064MX PROGRAMMER’S GUIDE
Parameter Descriptions • Set Date And Time Set Time To set the time, scan the SET TIME symbol. Next, scan six bar codes in two digit sequences using the symbols 0 to 9 to set the time in the form HHMMSS where H is the hour in range 00-23, M is minutes in range 00-59, and S is seconds in range 00-59. The sequence includes an error check; invalid entries are indicated by 2 beeps and the sequence aborted. If the time has been correctly established, the scanner will issue a warble beep on the 6th bar code.
Set Date To set the date scan the SET DATE symbol. Now scan six bar codes in two digit sequences using the symbols 0 to 9 to set the date in the form YYMMDD, where Y is the year in the range 00-99, M is month in the range 01-12, and D is day in the range 01- XX dependant on month. The sequence includes an error check and invalid entries are signalled by two beeps and the sequence aborted. A warble beep will be issued on the 6th bar code if the date has been correctly established. Date and time are appended in the form: YYMMDDHHMMSS#Data If date only: YYMMDD#Data If time only: HHMMSS#Data where: YY = year MM = month DD = day # = space
P22
HH - hour MM = minute SS = second
Page 54
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus • Set Date And Time (Contd) Note: Data is sent out of the scanner port as Code 39 if one or more of the following conditions are true: • Data compression is enabled in Storage Mode • Convert All to Code 39 is enabled • Time and/or Date is appended to data • Quantity Field is enabled and sent as Qxxxx
P23
Page 55
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Set Defaults Code Types ScanStand Time-out Laser On Time Fixed Length for Code 2 of 5 Decode Options Decode UPC/EAN Supplementals UPC-E/UPC-A Preamble Baud Rate Data Format Parity Stop Bits DTR Polarity Check Parity Hardware Handshaking Software Handshaking Prefix Suffix Intercharacter Delay Transmission Mode Select Format Options Set Serial Number Abort Procedure Quantity Field Transmit Quantity Terminating String Interdecode/Terminating String Delay Transmit Retry Time-out Low Battery Check Compress Mode Autodiscriminate Power Mode IntelliStand Options Date and Time Options Set Date and Time
P24
P25 P26-P27 P28-P29 P30-P32 P33-P34 P35-P36 P37-P38 P39-P40 P41-P42 P43-P44 P45-P46 P47-P48 P49-P50 P51-P52 P53-P54 P55-P56 P57-P58 P59-P60 P61-P62 P63-P64 P65-P67 P68-P71 P72-P73 P74-P75 P76-P77 P78 P79-P80 P81-P82 P83-P84 P85-P86 P87-P88 P89-P90 P91-P92 P93-P94
Page 56
LS 3064MX PROGRAMMER’S GUIDE
Set Defaults Scanning the SET DEFAULTS bar code configures all parameters to the default values shown on pages P3-P6. You will hear a warble beep if the scanner was programmed successfully for the default values.
SET DEFAULTS
Note: Two long beeps will be heard if the SET DEFAULTS symbol is scanned and there is data in the storage buffer. Buffered data must be downloaded or deleted before configuring parameters to the default values.
P25
Page 57
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Code Types These two options either add or delete a code type. To add a code: 1. Scan the ENABLED bar code. 2. Scan the bar code corresponding to the code type to be added. 3. Scan ENTER . To delete a code: 1. Scan the DISABLED bar code. 2. Scan the bar code corresponding to the code type to be deleted. 3. Scan ENTER .
ENABLED
DISABLED
CODE 39
CODE 39 FULL ASCII
CODE 93
P26
Page 58
LS 3064MX PROGRAMMER’S GUIDE
Code Types
UPC/EAN
I 2 OF 5
D 2 OF 5
CODE 128
ALL CODES
CODABAR
BACKSPACE - deletes the last bar code scanned. CANCEL - deletes entire change and returns you to the decode mode. ENTER - stores and enters the new change.
ENTER
BACKSPACE
CANCEL
P27
Page 59
LS 3064MX PROGRAMMER’S GUIDE
Parameter Menus Scanstand Time-out To select a ScanStand time-out: 1. Scan the SCANSTAND TIME-OUT bar code. 2. Scan the bar code corresponding to the desired time-out. 3. Scan ENTER .
SCANSTAND TIME-OUT
P28
Page 60
LS 3064MX PROGRAMMER’S GUIDE
Scanstand Time-out (Continued)
15 MINUTES
60 MINUTES
30 MINUTES
75 MINUTES
45 MINUTES
90 MINUTES
BACKSPACE - deletes the last bar code scanned. CANCEL - deletes the entire change and returns the user to the decode mode. ENTER - stores and enters the new change.
BACKSPACE
ENTER
CANCEL
P29