For the Symbol LS-3603
Page 31
Programming
Set Default Parameter 2-4 Host Interface Code 2-4 Code Types 2-4 Code Lengths 2-4 Code 39 Full ASCI 2-5 Decode Options UPC-E/UPC-A Check Digit 2-5 Convert UPC-E to UPC-A 2-5 EAN Zero Extend 2-5 Transmit No Decode Message 2-5 UPC/EAN Supplemental 2-6 Code 39 Check Digit 2-6 ITF-14/EAN-13 Conversion 2-6 MSI/Plessey Check Digit 2-6 MSI/Plessey Check Digit Alg. 2-6 Buffer Code 39 2-7 Beep After Good Decode 2-7 CLSI Editing 2-7 NOTIS Editing 2-7 UPC/EAN Security Level 2-8 Codabar Decode Redundancy 2-8 UPC-E/UPC-A Preamble 2-9 Data Transmission Formats 2-9 Prefix/Suffix Values 2-9 Laser On Time-out 2-9
RS-232C Options Baud Rate Parity Beep on BEL Hardware Handshaking Software Handshaking Stop Bit Select ASCII Data Format Intercharacter Delay Transmit Code ID Character Transmit AIM ID Character Power Mode Scanstand/IntelliStand
2-10 2-10 2-10 2-10 2-13 2-15 2-15 2-15 2-15 2-15 2-16 2-16
Wand Emulator Options Wand Bar Output Variable Leading Margin Convert All to Code 39
2-16 2-16 2-16
For a listing of corresponding bar codes, see page 3-1.
2-3
Page 32
LS 3603 Product Reference Guide
Parameter Descriptions • Set Parameter Defaults Scanning the SET ALL DEFAULTS bar code on page 3-3 returns all parameters to the values listed in the Default Table. (See page 2-29.)
• Host Interface Code Scan the bar code corresponding to your host type. You must select a host type when you first set up the scanner and whenever you change host types.
• Code Types The bar code menu selections enable the scanner to decode any or all of the following symbologies. • UPC Versions A and E (EAN 8 and 13) • Codabar • Code 39 • Code 39 Full ASCII • Discrete 2 of 5 • Interleaved 2 of 5 • Code 128 • MSI Plessey • EAN 128 • Code 93
The scanner will autodiscriminate between all of the above symbologies, except for Code 39 and Code 39 Full ASCII.
• Code Lengths Select one or two lengths for the Interleaved or Discrete 2 of 5 codes. Determine the number of characters represented in the Discrete 2 of 5 or Interleaved 2 of 5 bar codes by counting the number of printed (i.e., human readable) digits beneath the bar code. Set one or both lengths, one per scanning sequence. For D 2 of 5, LENGTH 1 may range from 02-55 and LENGTH 2 from 00-55. For I 2 of 5, LENGTH 1 may range from 02-54 and LENGTH 2 from 00-54. 2-4
Page 33
Programming
• Code 39 Full ASCII The ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. See the tables beginning on page 2-23 Code 39 Full ASCII interprets the bar code control character ($ + % /) preceding a Code 39 symbol and assigns an ASCII character value. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it will be interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. The LS 3603 will not autodiscriminate between Code 39 and Code 39 Full ASCII.
• Decode Options Transmit UPC-E/UPC-A Check Digit Select if decoded UPC symbols are transmitted with or without a check digit.
Convert UPC-E to UPC-A Use this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data will follow UPC format and be affected by UPC-A programming selections (e.g., Preamble, Check Digit).
EAN Zero Extend This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
Transmit “No Decode” Message This feature gives you the option to transmit “NR” when a symbol does not decode. Prefixes and suffixes enabled will be appended around this message.
2-5
Page 34
LS 3603 Product Reference Guide
• Decode Options (Continued) Decode UPC/EAN Supplemental Select whether UPC/EAN is decoded with or without supplemental characters. Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LS 3603 will, after additional processing to ensure a good decode, transmit either. (NOTE: In order to minimize the risk of invalid data transmission, it is recommended that you select whether to read or ignore supplemental characters.)
Code 39 Check Digit When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with the modulo 43 check digit algorithm.
ITF-14/EAN-13 Conversion If your terminal supports EAN-13, this feature converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length (either LENGTH 1 or LENGTH 2) must be set to 14, the code must have a leading zero and a valid EAN-13 check digit.
MSI Plessey Check Digit One or two digits at the end of the bar code that check the integrity of the data. At least one check digit (default) is always required. Check digits are not transmitted with the data.
MSI/Plessey 2 Check Digit Algorithm When the two MSI/Plessey check digits option is selected, an additional verification is required to ensure integrity. Either of two algorithms may be selected; Mod10 - Mod10 (default), or Mod11 - Mod10.
2-6
Page 35
Programming
• Decode Options (Continued) Code 39 Buffering (Scan & Store) When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See page 2-21 for further details. When the scan and transmit option is selected, decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer. Scan and Store affects Code 39 decodes only. If you select scan and store, it is recommended that you configure the scanner to decode Code 39 symbology only.
Beep After Good Decode Determine if the unit beeper will sound during normal scanning. Usually it is desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. Beeper indications begin on page 2-19.
CLSI Editing This parameter strips the start and stop characters, then inserts a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. Symbol length does not include start and stop characters.
NOTIS Editing This option strips the start and stop characters from decoded Codabar symbols.
2-7
Page 36
LS 3603 Product Reference Guide
• Decode Options (Continued) UPC/EAN Security Level The LS 3603 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application. • Security Level 0 - This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in spec” UPC/EAN bar codes. • Security Level 1 - As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the misdecodes are limited to these characters, select this security level. • Security Level 2 - If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7 and 8, select this security level. • Security Level 3 - If you have tried Security Level 2, and are still experiencing mis-decodes, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level will significantly impair the decoding aggressiveness of the scanner.
Decode Redundancy for Codabar When enabled, a Codabar symbol must be decoded in both directions before being accepted as a successful decode.
2-8
Page 37
Programming
• UPC A and E Preamble Three options are given for the lead-in characters of decoded UPC-A or UPC-E symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are: • a system character only • the country code and system character • no preamble
The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.
• Data Transmission Formats Select the desired scan data format from one of the following: <data> <PREFIX> <data> <PREFIX> <data> <SUFFIX> <data> <SUFFIX> <data> = Scanned bar code data <PREFIX> <SUFFIX> as selected by the user
• Prefix/Suffix Values A prefix/suffix may be appended to scan data for use in data editing. These values are set by scanning a four digit number (i.e., four bar codes) that correspond to keycodes for various terminals. An ASCII table begins on page 2-23.
• Laser On Time-out The maximum time the laser will remain on or decode processing will continue during a trigger pull. Programmable in .5 sec increments from 0.5 to 5.0 sec.
2-9
Page 38
LS 3603 Product Reference Guide
•RS-232C Options Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting must match the data rate setting of the host device. If not, data will not reach the host device or may reach it in distorted form.
Parity A parity check bit is the most significant bit of each ASCII coded character. If you select ODD parity, the parity bit will have a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character. If you select EVEN parity, the parity bit will have a value 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. Select MARK parity and the parity bit will always be 1. Select SPACE parity and the parity bit will always be 0. Select the parity type according to host device requirements.
Beep on BEL When this parameter is enabled, the scanner will issue a beep when a <BEL> character is detected on the RS-232C serial line. <BEL> is issued to gain a user’s attention to indicate an illegal entry or other important event. When the scanner is configured for low power operation, it will not respond to BEL characters in between decode attempts.
Hardware Handshaking Hardware handshaking checks the readiness of the receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is needed to prevent loss of transmitted data. Hardware handshaking may not be used in conjunction with software handshaking. Refer to the flow chart on the following page. RS-232C communications are designed to operate either with or without hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send.
2-10
Page 39
Programming
RS-232C Options (Continued) Hardware Handshaking If RTS/CTS handshaking is selected, scan data is transmitted with the following sequence: (Note that the DTR signal is hard wired active.) • The scanner reads the CTS line for activity. If CTS is asserted, the scanner will wait up to two seconds for the host to negate the CTS line. If, after one second the CTS line is still asserted, the scanner will sound a transmit error and any scanned data will be lost. • When the CTS line is negated, the scanner asserts the RTS line and waits for two seconds for the host to assert CTS. When the host asserts CTS, data is transmitted. • When data transmission is complete, the scanner will negate RTS after sending the last character. • The host should respond by negating CTS. The scanner will check for a negated CTS upon the next transmission of data. During the transmission of data, the CTS line should be asserted. • If the above communications sequence should fail, the scanner will issue a transmit error. In this case, the data is lost and must be rescanned.
2-11
Page 40
LS 3603 Product Reference Guide
RS-232C Options (Continued)
HARDWARE HANDSHAKING [evec e Deo
WO RESPONSE, AFTER 2 SECONDS THE UNIT BEEPS TIRESTO
KOGATE 41h ASM SSN ERROR VES (CT Ae 6 ERT ED? IFSTLL ASSERTED WFTER 1 EEC, INDICATE wo TRed SSM ERROR eG ERT Te ao CTé Aeé ERT ED? IF WOT ASSERTED AFTER 1 EEC, INDACATE YES TRed SESW ERROR THAR GM DATA i ¥ Fu GH ED
Figure 2-1. Hardware Handshaking
2-12