Page 21
User’s Guide
What If... Nothing happens when you follow the operating instructions? You Should • Check the system power; is there a battery in the battery box? • Be sure the scanner is programmed for the terminal in use. • Make sure the scanner is programmed to read the type of bar code you are scanning. • Check for loose cable connections. • Check the symbol to make sure it is not defaced. • Try scanning test symbols of the same code type.
Symbol is decoded, but not transmitted to the host terminal? You Should • Be sure the proper host type is selected (See Chapter 2). • Make sure the appropriate parameter set (RS-232, Wand, Synapse) is selected.
Scanned data is incorrectly displayed on the terminal? You Should • Make sure the system is programmed for the correct keyboard type. • Make sure the CAPS LOCK key is off. • Be sure the proper host is selected. • Be sure editing options (e.g. UPC-E to UPC-A Conversion) are properly programmed. Note: If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. See page 1-15 for the telephone number. 1-13
Page 22
LS 3603 Product Reference Guide
Factory Service If you have a problem, contact the Symbol Support Center at the telephone number on page 1-15. Before calling, have the model number and several of your bar code symbols at hand. Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem. If the equipment is found to be working properly and the problem is symbol readability, Support will request samples of your bar codes for analysis at our plant. If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions.
Note: Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.
1-14
Page 23
User’s Guide
Symbol Support Center In the U.S.A., for service information, warranty information or technical assistance call:
SYMBOL SUPPORT CENTER 1-800-653-5350 If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.
Canada Mississauga, Ontario Canadian Headquarters (905) 629-7226
Europe Wokingham, England European Headquarters 01734-771-222 (Inside UK) +44-1734-771222 (Outside UK)
Asia Singapore Symbol Technologies Asia, Inc. 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore)
1-15
Page 24
LS 3603 Product Reference Guide
Accessories Required Accessories LS 3603 scanners are sent as a package with required accessories, listed in the Product Ordering Guide. Optional accessories are available at extra cost.
Optional Accessories Optional accessories, listed in the Product Ordering Guide, include various stands and holders, which are supplied at extra cost. Additional units of standard accessories may also be purchased at extra cost.
1-16
Page 25
User’s Guide
Technical Specifictions Table 1-1. Technical Specifications ITEM
DESCRIPTION
Power Requirements* Wand RS-232C Synapse
4.8 (min) to 14.0 VDC (max) 150 mA @ 5V typical 150 mA @ 5V typical 150 mA @ 5V typical
Decode Capability
The LS 3603 can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, Code 93, and MSI/Plessey. Set code length(s) for any 2 of 5 code type. The LS 3603 can autodiscriminate between all of the above code types except for Code 39 and Code 39 Full ASCII. Transmission of decoded information will depend on the capabilities of the attached terminal.
Beeper Operation
User-selectable: Enabled, Disabled.
Scan Repetition Rate
36 (± 3) scans/sec (bidirectional)
Roll (Skew) Tolerance
± 10° from normal
Pitch
± 50° from normal
Yaw
± 60° from normal
Decode Depth of Field
See Decode Zone
Print Contrast Minimum
25% absolute dark/light differential, measured at 675 nm.
Ambient Light Immunity Artificial Lighting Sunlight
200 ft. candles 8000 ft. candles
2153 lux 86112 lux (@8 in. (20 cm) on low density bar codes)
1-17
Page 26
LS 3603 Product Reference Guide
Table 1-1. (Continued) Technical Specifications ITEM
DESCRIPTION
Operating Temperature
-22° to 122°F
-30° to 50°C
Storage Temperature
-40° to 140°F
-40° to 60°C
Humidity
5% to 95% (non-condensing)
Coil Cable Length
9-12 ft.
Durability
6-ft. drop to concrete 1.8 m
Dimensions Height Length Width
6.3 in. 5 in. 2.8 in.
Laser Classifications
274-365 cm (depending on host)
16 cm 12.7 cm 7.1 cm
CDRH Class II IEC 825 Class 2
*For direct host power connection, make sure the host terminal supplies sufficient power for the specified operation. Symbol is not responsible for damage to host equipment or system mis-operation due to an insufficient power condition.
1-18
Page 27
User’s Guide
Pin-outs Table 1-2. Pin-outs PIN
RS-232
Wand
Synapse
1
Not Used
Not Used
Not Used
2
VBAT 4.8-14.0V
VBAT 4.8-14.0V
VBAT 4.8-14.0V
3
Ground
Ground
Ground
4
RTS Output
RTS Output
Not Used
5
RxD Input
Not Used
Not Used
6
Not Used
Not Used
ZIF_CLOCK
7
DTR Output
Not Used
Not Used
8
TxD Output
DBP Output
Not Used
9
CTS Input
CTS Input
Not Used
10
Not Used
Not Used
ZIF_DATA
1-19
Page 28
LS 3603 Product Reference Guide
1-20
Page 29
Chapter 2 Programming Overview Before programming, follow the instructions beginning on page 1-2 The LS 3603 is programmed by scanning appropriate bar codes. The bar codes are arranged in RS-232C, Wand and Synapse sections. Not all of the available parameters necessarily apply to your specific host systems. If, for example, the selected host is a wand emulator, and you enable Baud Rate, the parameter will be ignored until such time as a host recognizing that parameter is selected. You can program any parameter, regardless of the mode you're in. For example, if you are in the Wand mode, you can still program Synapse and RS-232C parameters. When you switch from one mode to another, stored parameters remain unchanged. That means you can switch back and forth between RS-232C, Wand and Synapse modes without having to re-program the scanner. Consult the Parameter Descriptions section beginning on page 2-3 for explanations of parameter types. A table of features supported by each host type begins on page 2-17. There are separate defaults for each mode, and one for All Defaults. If the default values suit your requirements, all you need to do is scan the appropriate Set Default bar code. Parameters other than default values can be set by scanning sequences of bar codes. Parameter Menus contain all the bar codes necessary to program the scanner for each parameter selection. Regardless of whether or not you change defaults, if you select RS-232C or Wand mode, you must then select a host type. If you are using a Synapse Smart Cable, the host type will automatically be selected for you when you plug in the cable. Remember to look at the top of the page to see whether the bar codes apply to RS-232C, Wand or Synapse parameters.
2-1
Page 30
LS 3603 Product Reference Guide
Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter. For example, if you want to add Code 39 to the Wand parameters, simply scan the Add Code 39 bar code in the Wand Code Types section. The LS 3603 will issue a warble tone, signifying a successful parameter entry. If you want to add or change prefixes and suffixes you will have to scan several bar codes. This procedure is described in Parameter Descriptions.
Errors While Scanning Don't worry if you make an error during a scanning sequence. Merely reenter the correct parameter.
2-2