The text of a manual · part 5 of 14
LS 3603 Product Reference Guide, pages 41 to 50
Pages 41 to 50 of 138
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-3603
Page 41
Programming
RS-232C Options (Continued) Software Handshaking This parameter controls the data transmission process. It may be used instead of, but not in conjunction with, hardware handshaking. The scanner provides five software handshaking options, listed below. Refer to the flow chart on the following page. 1. None 2. ACK/NAK Only The ACK/NAK option checks the result of a transmission. The scanner expects one of the following host responses after a data transmission: <ACK> - Acknowledges a valid and successful transmission. <NAK> - Indicates a problem with the transmission. Whenever a <NAK> is received, the unit retransmits the same data and awaits an ACK/NAK response. After three unsuccessful attempts to transmit the same data, the scanner aborts any further communication attempts on that message. Transmission error is indicated by the unit sounding 4 short beeps. 3. ENQ ONLY The ENQ option needs the host to request data before it is transmitted to the host. This ensures that data transmission occurs only when the host is ready to receive. When you select the ENQ option, the scanner waits for an ENQ, Enquire character, from the host before it transmits data; otherwise the unit transmits data without waiting for an ENQ character from the host. With ENQ enabled, the scanner must receive an ENQ from the host within a 2 second period after the last activity or 4 short beeps are sounded to indicate a transmission error; the unit is now ready to scan again. 4. ACK/NAK with ENQ This combines both handshaking options.
2-13
Page 42
LS 3603 Product Reference Guide
RS-232C Options (Continued) Software Handshaking 5. XON/XOFF When enabled, the scanner assumes an XON for the first transmission, and transmits scanned data until an XOFF is received. Transmission continues when an XON character is received. This option is automatically disabled when the unit is in Low Power mode.
Figure 2-2. Software Handshaking
2-14
Page 43
Programming
RS-232C Options (Continued) Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
ASCII Format When enabled, this parameter transmits data in an 8-bit ASCII format. This allows the scanner to interface with devices requiring that protocol. The default is 7-bit ASCII.
• Intercharacter Delay Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 msec delay between the transmission of each character.
• Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. If a prefix is selected, the code ID character is sent after the prefix. Code ID characters are: A = UPC - A, UPC - E, EAN - 13, or EAN - 8; B = Code 39; C = Codabar; D = Code 128; E = Code 93; F = Interleaved 2 of 5; G = Discrete 2 of 5; K = EAN 128; J = MSI Plessey.
• Transmit AIM ID Character Enabling this parameter, with the Transmit Code ID Character parameter enabled allows you to send the AIM code identifier in lieu of the Symbol identifiers listed above. The identifier will be sent as a three character prefix, in accordance with AIM specifications for symbology identifiers. See AIM’s Guidelines on Symbology Identifiers for full details.
2-15
Page 44
LS 3603 Product Reference Guide
• Power Mode This parameter determines whether or not power remains on after a decode attempt. When in low power mode, the scanner powers down after each decode attempt. When in continuous power mode, power remains on after each decode attempt. To ensure the integrity and proper operation of this product, it is recommended that the low power mode be set for RS-232C and Wand modes, and continuous power mode for Synapse mode.
• Scanstand/IntelliStand Time-out Scanstand/IntelliStand operation can be programmed to shut down if no bar code is detected within the specified time. Duration is programmable in 15 minute increments from 15 minutes to 90 minutes.
•Wand Emulator Options Wand Emulator Bar Output The polarity of the wand emulator output is set automatically when the Wand Host type is selected. This parameter can be used to change the default polarity setting to match the type of signal (bar = logic high, or bar = logic low) expected by the receiving system
Variable Leading Margin This parameter allows the selection of a variable leading margin, ranging from 80 msec to 200 msec, in 10 msec increments.
Convert All to Code 39 This parameter converts the output of all data to Code 39 format. Any coded character not in the Code 39 character set is replaced by a Code 39 blank.
2-16
Page 45
Programming
Supported Features By Host Type Table 2-1. Supported Features by Host Type DECODE PARAMETERS
RS-232C
Wand
Synapse
Add Codes to be Decoded
X
X
X
ASCII Format
X
Bar High/ Bar Low
X
Baud Rate
X
Beep After Good Decode
X
Beep on BEL
X
Code 39 Buffering
X
X
Code 39 Check Digit
X
X
Convert All to Code 39
X
X
X
Convert UPC-E to A
X
X
D 2 of 5 Lengths
X
Data Transmission Formats
X
Decode Redundancy for Codabar
X
EAN Zero Extend
X
Hardware Handshaking
X
Host Interface Select
X
Intercharacter Delay
X
I 2 of 5 Lengths
X
ITF-14/EAN-13 Conversion
X
Laser On Time-out
X
X
X
MSI Plessey 2 Check Digit Alg.
X
X
X
Number of Stop Bits
X
Parity
X
Prefix/Suffix
X
Power Mode
X
X
X X
X
X X
X
X
X
X X
X X
X
2-17
Page 46
LS 3603 Product Reference Guide
Table 2-1. (Continued) Supported Features by Host Type DECODE PARAMETERS
RS-232C
Wand
Synapse
Scanstand/Intellistand
X
X
X
Software Handshaking
X
Transmit AIM ID Character
X
X
Transmit Code ID Character
X
X
Transmit MSI Check Digit
X
X
Transmit No Decode Message
X
X
Transmit UPC-A Check Digit
X
X
Transmit UPC-E Check Digit
X
X
UPC/EAN Security Level
X
X
X
UPC/EAN Supplemental
X
X
X
UPC-E/UPC-A Preamble
X
X
Wand Bar Output
X
Wand Leading Margin
X
2-18
Page 47
Programming
Beeper Indications Table 2-2. Beeper Indications Standard Use Beeper Sequence
Indication
1 Beep - short high tone
A bar code symbol was decoded (if decode beeper is enabled).
4 Beeps - short high tone
Low battery power.
4 Beeps - long low tone
A format or transmission error has been detected in a scanned symbol. The data is ignored. This will occur if a unit is not properly configured. Check option settings.
Parameter Menu Scanning 1 Beep - short high tone
Correct entry scanned or correct menu sequence performed.
1 Beep - lo/hi tone
Input error, incorrect bar code or “Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.
1 Beep - hi/lo tone
Keyboard parameter selected. Enter value using bar code keypad.
1 Beep - hi/lo/hi/lo tone
Successful program exit with change in the parameter setting.
2-19
Page 48
LS 3603 Product Reference Guide
Table 2-2. (Continued) Beeper Indications Code 39 Buffering Beeper Sequence
Indication
1 Beep - hi/lo tone
New Code 39 data was entered into the buffer.
3 Beeps - long high tone
Code 39 buffer is full.
1 Beep - lo/hi/lo tone
The buffer was erased, or there was an attempt to transmit an empty buffer. When the Code 39 buffer was empty, the scanner read a command to clear or to transmit a Code 39 buffer.
2 Beeps - long high tone
Error in data transmission.
1Beep - lo/hi tone
A successful transmission of buffered data.
2-20
Page 49
Programming
Code 39 Buffering While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. The buffer will hold 250 bytes of information. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer) or clear the buffer.
Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, unit gives hi/lo beep to indicate successful decode and buffering. See Overfilling Transmission Buffer. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission will occur.
Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission will occur.
CLEAR BUFFER
2-21
Page 50
LS 3603 Product Reference Guide
Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. • The unit signals that the transmission buffer has been sent (a hi/lo beep). • Unit sends the buffer. • Unit clears the buffer.
TRANSMIT BUFFER
2. A Code 39 bar code with leading character other than a space. • The unit signals a good decode and buffering of that decode has occurred by giving a hi/lo beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted with a lo/hi beep.
Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission will occur. Data in buffer is not affected.
Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty.
2-22