Page 11
Chapter 1 Introduction and Set-up Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Set-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Installing the Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Switching Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Connecting to a Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 RS-232C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 For external power operation with Synapse “Smart Cable” . . . . . . . . . . . . . . . . . . . . . 1-6 For external power operation with Flying Lead Connector . . . . . . . . . . . . . . . . . . . . . 1-7 For external power operation with 25-pin Host Connector . . . . . . . . . . . . . . . . . . . . . 1-8 For battery operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 IBM 468X/9X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Wand Emulation, OCIA, OCR, and Keyboard Wedges. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1-1
Page 12
LS 1000 Series Product Reference Guide
1-2
Page 13
Introduction and Set-Up
Introduction Symbol Technologies Inc., the world leader in hand-held laser scanning now offers 21st century technology, while maintaining compatibility with today’s existing systems. The LS 1000 Series of hand-held laser scanners offers the best performance in retail and light industrial applications. Advanced ergonomic design ensures comfortable use for extended periods of time. The LS 1000 series hand-held scanner is based on the Visible Laser Diode (VLD). This state of the art technology gives the scanner a wider decode zone, greater depth of field, and a visible scan beam. This model reads color bar codes and symbols printed on all substrates. See the LS 1000 Decode Zone on page 3-8. Here’s what each member of the LS 1000 family offers you: • LS 1000 - The aggressiveness of this discrete scanner is typical of the
LS 1000 family’s performance. It connects easily to, and is programmed by, the complete line of Symbol Technologies portable terminals and the full range of SYMBOLLINK® and OmniLinktm interface controllers. • LS 1004 - With a simple cable change, this scanner is compatible with:
- RS 232C asynchronous terminals - Synapsetm “Smart Cables”, which allow you to connect to IBM 4683/4, 4693/4 series of terminals All leading OCIA terminals, including NCR, Nixdorf, and ICL terminals, using an XT, AT, or PS/2 -style keyboard (when using as a keyboard wedge, all scanned data is entered into your terminal in the form of keystrokes - no changes to your host system are necessary) - Popular OCR terminals, such as Fujitsu and ICL. All of the LS 1000 series scan automatically at the rate of 36 scans per second. For decode capability, see Technical Specifications beginning on page 3-8.
Audience The intended audience for this manual is personnel performing installation/ setup and programming of LS 100x scanners.
1-3
Page 14
LS 1000 Series Product Reference Guide
Set-Up Unpacking Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed in the front of this manual. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.
Installing the Cable 1. Insert the cable into the receptable on the bottom of the scanner, as shown below:
1-4
Page 15
Introduction and Set-Up
2. Twist the cable to the left to lock in place, as shown below:
Switching Cables Different cables are required for different hosts. To change the scanner cable: 1. “Unlock” the cable by twisting to the right. 2. Pull the cable out of the receptacle on the bottom of the scanner.
3. Insert a new cable in the receptacle. 4. Twist to the left to lock the new cable in place.
1-5
Page 16
LS 1000 Series Product Reference Guide
Connecting to a Host With some terminal types, the LS 100x is unable to answer host terminal polls until the appropriate host type is selected. This may result in an error message generated by the host. To correct this situation, select proper parameter values and initialize the host terminal. See Chapter 4 for more information.
RS-232C For external power operation with Synapse “Smart Cable” • Plug the scanner into the Synapse “Smart Cable”. • Connect the Synapse cable with the host connector. • Connect the power supply to the input receptacle located on the Synapse cable.
Figure 1-1. RS-232C External Power Connection using Synapse Cable
1-6
Page 17
Introduction and Set-Up
For external power operation with Flying Lead Connector • Plug the cable into the scanner. • Plug the Power Supply into the receptacle on the Flying Lead connector.
Figure 1-2. RS-232C External Power Connection: Flying Lead Connector to a 9-pin Host Connector
1-7
Page 18
LS 1000 Series Product Reference Guide
For external power operation with 25-pin Host Connector • Plug the cable into the scanner. • Plug the Power Supply into the receptacle on the side of the 25-pin Host
Connector
Figure 1-3. RS-232C External Power Connection: 25-pin Host Connector
1-8
Page 19
Introduction and Set-Up
RS-232C (Contd) For battery operation: • Insert a 9-volt battery into the battery box. See the Battery Box
Operation section on page 3-4. • Plug the scanner's 9-pin connector at the end of the cord into one end of the battery box. • An output cable from the battery box connects the LS 1000 to the RS-
232C input device. Connect one end of this cable to the battery box and the other to the appropriate port on the host device.
Figure 1-4. RS-232C Operation
1-9
Page 20
LS 1000 Series Product Reference Guide
IBM 468X/9X Plug the SDL modular connector at the end of the selected Synapse “Smart” cable into the appropriate port (5B, 9B, 9C, 9E, or 17). Check that the connection is secure. To install an LS 1004 on an IBM 468X/469X host: 1. Connect a synapse adaptor cable to the scanner, using the procedure described in “Installing the Cable” on page 1-4. 2. Plug the other end of the adaptor cable into the synapse cable’s female connector. Spark
Figure 1-5. Typical System Configuration
1-10
Page 21
Introduction and Set-Up
IBM 468X/9X (Contd)
PORT 5B
PORT 9B
PORT 17
Figure 1-6. IBM 4683 Rear Panel with Cover Removed
9B
5B 17
Figure 1-7. IBM 4684 Rear Panel with Cover Removed
1-11
Page 22
LS 1000 Series Product Reference Guide
IBM 468X/9X (Contd)
5B
9C 9B
Figure 1-8. IBM 4693 Rear Panel with Cover Removed
PORT 9E
IBM 4694 REAR PANEL WITH COVER REMOVED Figure 1-9. IBM 4694 Rear Panel with Cover Removed
Wand Emulation, OCIA, OCR, and Keyboard Wedges A Synapse Adaptor Cable is required when connecting the LS 1004 to any of these hosts using Synapse. See the instructions packed with the appropriate Synapse cable.
1-12