The text of a manual · part 12 of 13

LS 1000 Series Product Reference Guide: Chapter 5 Glossary, pages 87 to 95

Pages 87 to 95 of 104, from LS 1000 Series Product Reference Guide

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-1004

Page 87

Chapter 5 Glossary ASCII - American Standard Code for Information Interchange. A 7 bit code representing 128 letters, numerals, punctuation marks, and control characters. It is a standard data transmission code in the U.S. BIT - Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning. BOOKLAND EAN - A specially-formatted European Article Numbering symbol with 13 characters (EAN-13), the first 3 of which are “978”. BYTE - On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character. CDRH - Center for Devices and Radiological Health. A federal agency responsible for regulating laser product safety. This agency specifies various laser operation classes based on power output during operation. CHECK DIGIT - A digit used to verify a correct symbol decode. The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit. Check digits are required for UPC but are optional for other symbologies. Using check digits decreases the chance of substitution errors when a symbol is decoded. CODABAR - A discrete self-checking code with a character set consisting of digits 0 to 9 and six additional characters: (- $ : / , +). CODE 128 - A high density symbology which allows the controller to encode all 128 ASCII characters without adding extra symbol elements.

5-1

Page 88

LS 1000 Series Product Reference Guide

CODE 3 OF 9 (CODE 39) - A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9, and 7 special characters (- . / + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow. CODE 93 - An industrial symbology compatible with Code 39 but offering a full character ASCII set and a higher coding density than Code 39. CONTINUOUS SYMBOLOGY - A bar code or symbol in which all spaces within the symbol are parts of characters. There are no intercharacter gaps in a continuous code. The absence of gaps allows for greater information density. DECODE - To recognize a bar code symbology (e.g., UPC/EAN) and then analyze the content of the specific bar code scanned. DECODE ALGORITHM - A decoding scheme that converts pulse widths into data representation of the letters or numbers encoded within a bar code symbol. DISCRETE SYMBOLOGY - A bar code or symbol in which the spaces between characters (intercharacter gaps) are not part of the code. DISCRETE 2 OF 5 - A binary bar code symbology representing each character by a group of five bars, two of which are wide. The location of wide bars in the group determines which character is encoded; spaces are insignificant. Only numeric characters (0 to 9) and START/STOP characters may be encoded. EAN - European Article Number. This European/International version of the UPC provides its own coding format and symbology standards. Element dimensions are specified metrically. EAN is used primarily in retail. HOST COMPUTER - A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs, and network control. IEC - International Electrotechnical Commission. This international agency regulates laser safety by specifying various laser operation classes based on power output during operation.

5-2

Page 89

Glossary

IEC CLASS I (IEC 825 Class I) - This is the lowest power IEC laser classification. Conformity is ensured through a software restriction of 25 seconds of laser operation within any 100 second window and an automatic laser shutdown if the scanner's oscillating mirror fails. INTERCHARACTER GAP - The space between two adjacent bar code characters in a discrete bar code. INTERLEAVED BAR CODE - A bar code in which characters are paired together, using bars to represents the first character and the intervening spaces to represent the second. INTERLEAVED 2 OF 5 - A binary bar code symbology representing character pairs in groups of five bars and five interleaved spaces. Interleaving provides for greater information density. The location of wide elements (bar/spaces) within each group determines which characters are encoded. This continuous code type uses no intercharacter spaces. Only numeric (0 to 9) and START/ STOP characters may be encoded. LASER - An acronym for Light Amplification by Stimulated Emission of Radiation. The laser is an intense light source. Light from a laser is all the same frequency, unlike the output of an incandescent bulb. Laser light is typically coherent and has a high energy density. LASER DIODE - A semiconductor type of laser connected to a power source to generate a laser beam. This laser type is a compact source of coherent light. PARAMETER - A variable that can have different values assigned to it. PROGRAMMING MODE - The state in which a scanner is configured for parameter values. See SCANNING MODE. QUIET ZONE - A clear space, containing no dark marks, which precedes the start character of a bar code symbol and follows the stop character. REDUNDANCY - A decoding method which requires a bar code be recognized redundantly on a number of sweeps of the scan beam before a decode is declared. While slowing the time-to-decode, redundancy can help lower the possibility of a mis-decode of poorly printed symbols.

5-3

Page 90

LS 1000 Series Product Reference Guide

SCANNER - An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Its three main components are: 1. Light source (laser or photoelectric cell) - illuminates a bar code. 2. Photodetector - registers the difference in reflected light (more light reflected from spaces). 3. Signal conditioning circuit - transforms optical detector output into a digitized bar pattern. SCANNING MODE - The scanner is energized, programmed, and ready to read a bar code. SCANNING SEQUENCE - A method of programming or configuring parameters for a bar code reading system by scanning bar code menus. SELF-CHECKING CODE - A symbology that uses a checking algorithm to detect encoding errors within the characters of a bar code symbol. START/STOP CHARACTER - A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction. The start and stop characters are normally to the left and right margins of a horizontal code. SYMBOL - A scannable unit that encodes data within the conventions of a certain symbology, usually including start/stop characters, quiet zones, data characters, and check characters. SYMBOLOGY - The structural rules and conventions for representing data within a particular bar code type (e.g. UPC/EAN, Code 39). UPC - Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which can be any of four widths. The standard symbology for retail food packages in the United States.

5-4

Page 91

Appendix A ASCII Character Set

Table A-1. ASCII Character Set ASCII Value

Full ASCII Code 39 Encode Char.

Keystroke

ASCII Value

Full ASCII Code 39 Encode Char

Keystroke

000

%U

CTRL 2

024

$X

CTRL X

001

$A

CTRL A

025

$Y

CTRL Y

002

$B

CTRL B

026

$Z

CTRL Z

003

$C

CTRL C

027

%A

CTRL [

004

$D

CTRL D

028

%B

CTRL \

005

$E

CTRL E

029

%C

CTRL ]

006

$F

CTRL F

030

%D

CTRL 6

007

$G

CTRL G

031

%E

CTRL -

008

$H

CTRL H

032

Space

Space

009

$I

CTRL I

033

/A

!

010

$J

CTRL J

034

/B

‘

011

$K

CTRL K

035

/C

#

012

$L

CTRL L

036

/D

$

013

$M

CTRL M

037

/E

%

014

$N

CTRL N

038

/F

&

015

$O

CTRL O

039

/G

‘

016

$P

CTRL P

040

/H

(

017

$Q

CTRL Q

041

/I

)

018

$R

CTRL R

042

/J

*

019

$S

CTRL S

043

/K

+

020

$T

CTRL T

044

/L

,

A-1

Page 92

LS 1000 Series Product Reference Guide

Table A-1. (Continued) ASCII Character Set 021

$U

CTRL U

045

-

-

022

$V

CTRL V

046

.

.

023

$W

CTRL W

047

/

/

ASCII Value

Full ASCII Code 39 Encode Char.

Keystroke

ASCII Value

Full ASCII Code 39 Encode Char

Keystroke

048

0

0

073

I

I

049

1

1

074

J

J

050

2

2

075

K

K

051

3

3

076

L

L

052

4

4

077

M

M

053

5

5

078

N

N

054

6

6

079

O

O

055

7

7

080

P

P

056

8

8

081

Q

Q

057

9

9

082

R

R

058

/Z

:

083

S

S

059

%F

;

084

T

T

060

%G

<

085

U

U

061

%H

=

086

V

V

062

%I

>

087

W

W

063

%J

?

088

X

X

064

%V

@

089

Y

Y

065

A

A

090

Z

Z

066

B

B

091

%K

[

067

C

C

092

%L

\

068

D

D

093

%M

]

069

E

E

094

%N

^

070

F

F

095

%O

_

071

G

G

096

%W

‘

A-2

Page 93

Appendix

Table A-1. (Continued) ASCII Character Set 072

H

H

097

+A a

ASCII Value

Full ASCII Code 39 Encode Char.

Keystroke

ASCII Value

Full ASCII Code 39 Encode Char

Keystroke

098

+B b

113

+Q q

099

+C c

114

+R r

100

+D d

115

+S s

101

+E e

116

+T t

102

+F f

117

+U u

103

+G g

118

+V v

104

+H h

119

+W w

105

+I i

120

+X x

106

+J j

121

+Y y

107

+K k

122

+Z z

108

+L l

123

%P

{

109

+M m

124

%Q

|

110

+N n

125

%R

}

111

+O o

126

%S

~

112

+P p

127

Undefined

Table A-2. ASCII Character Set Misc. Key

Keystroke

Misc. Key

Keystroke

Misc. Key

Keystroke

264

ALT 2

275

ALT K

286

ALT V

265

ALT A

276

ALT L

287

ALT W

266

ALT B

277

ALT M

288

ALT X

267

ALT C

278

ALT N

289

ALT Y

268

ALT D

279

ALT O

290

ALT Z

269

ALT E

280

ALT P

291

ALT [

270

ALT F

281

ALT Q

292

ALT \

A-3

Page 94

LS 1000 Series Product Reference Guide

271

ALT G

282

ALT R

293

ALT ]

272

ALT H

283

ALT S

294

ALT 6

273

ALT I

284

ALT T

295

ALT -

274

ALT J

285

ALT U

Misc. Key

Keystroke

Misc. Key

Keystroke

Misc. Key

Keystroke

301

PA 1

309

CMD 7

317

°

302

PA 2

310

CMD 8

318

1/2

303

CMD 1

311

CMD 9

319

304

CMD 2

312

CMD 10

320

§

305

CMD 3

313

¥

321

|

306

CMD 4

314

£

322

0/00

307

CMD 5

315

¤

308

CMD 6

316

¬

A-4

Page 95

Appendix

PF Keys

Keystroke

PF Keys

Keystroke

PF Keys

Keystroke

401

PF 1

409

PF 9

417

PF 17

402

PF 2

410

PF 10

418

PF 18

403

PF 3

411

PF 11

419

PF 19

404

PF 4

412

PF 12

420

PF 20

405

PF 5

413

PF 13

421

PF 21

406

PF 6

414

PF 14

422

PF 22

407

PF 7

415

PF 15

423

PF 23

408

PF 8

416

PF 16

424

PF 24

F Keys

Keystroke

F Keys

Keystroke

F Keys

Keystroke

501

F1

514

F 14

527

F 27

502

F2

515

F 15

528

F 28

503

F3

516

F 16

529

F 29

504

F4

517

F 17

530

F 30

505

F5

518

F 18

531

F 31

506

F6

519

F 19

532

F 32

507

F7

520

F 20

533

F 33

508

F8

521

F 21

534

F 34

509

F9

522

F 22

535

F 35

510

F 10

523

F 23

536

F 36

511

F 11

524

F 24

537

F 37

512

F 12

525

F 25

538

F 38

513

F 13

526

F 26

539

F 39

A-5