Page 69
Programming the LS 1004
I 2 of 5 Modulo 10 Check When enabled, this parameter checks the integrity of a Interleaved 2 of 5 symbol to ensure it complies with specific algorithms.
I 2of 5 Modulo 10 Check Digit Enable
I 2of 5 Modulo 10 Check Digit Disable
ITF14/EAN13 Conversion This feature converts a 14-character I 2 of 5 code into EAN13, and transmits to the host as EAN13. In order to accomplish this, the I 2 of 5 code must be enabled, one length (either LENGTH 1 or LENGTH 2) must be set to 14, the code must have a leading zero and proper trailing check digit.
ITF-14/EAN-13 Conversion Enable
ITF-14/EAN-13 Conversion Disable
4-25
Page 70
LS 1000 Series Product Reference Guide
Discrete 2 of 5 Enable/Disable D 2 of 5
Enable Code D 2 of 5
Disable Code D 2 of 5
D 2 of 5 Modulo 10 Check When enabled, this parameter checks the integrity of a Discrete 2 of 5 symbol to ensure it complies with specific algorithms.
D 2 of 5 Modulo 10 Check Digit Enable
D 2 of 5 Modulo 10 Check Digit Disable
Fixed Lengths for Code 2 of 5 Select one or two lengths for the Discrete 2 of 5 codes. If you set the both of them (Length 1 and Length 2) to 0, the scanner can read any length within 36 characters. It is recommended that you set the D 2 of 5 modulus 10 check to enabled when you set both Length 1 and Length 2 to 0. If any default setting is in effect and is an appropriate length, it need not be reset. Length 1 may range from 00-36 and Length 2 may range from 00-36
D 2 of 5 Length 1 (RANGE 00-36)
4-26
D 2 OF 5 Length 2 (Range 00-36)
Page 71
Programming the LS 1004
Fixed Lengths for Code 2 of 5 (cont’d)
0
1
2
3
4
5
6
7
8
9
CANCEL
4-27
Page 72
LS 1000 Series Product Reference Guide
Codabar Enable/Disable Codabar
Enable Codabar
Disable Codabar
CLSI Editing Use this parameter to insert a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. This symbol length includes start and stop characters.
Enable CLSI Editing
Disable CLSI Editing
NOTIS Editing This option strips the start and stop characters from decoded Codabar symbols.
Enable NOTIS Editing
4-28
Disable NOTIS Editing
Page 73
Programming the LS 1004
Data Options Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single-character prefixes already selected, the code ID character is appended as a prefix to the decode. The code ID characters are: ID Character
Meaning
A
UPC-A, UPC-E, EAN-13, EAN-8
B
Code 39
C
Codabar
D
Code 128
E
Code 93
F
Interleaved 2 of 5
G
Discrete 2 of 5 or Discrete 2 of 5 IATA
Transmit Code ID Character
Do Not Transmit Code ID Character
4-29
Page 74
LS 1000 Series Product Reference Guide
Prefix The scanner adds one of the following start-of-text characters to transmitted data. • None • Start-of-text (STX) • One user-defined prefix (can be any ASCII character) See the ASCII
Character Table in Appendix A for more information.
Prefix STX
Prefix None
User’s Choice Prefix Character
4-30
Page 75
Programming the LS 1004
Suffix • Select one or two end-of-text characters to be added to transmitted data. • None • CR (Carriage Return) - Returns the cursor to the same position on the line after each decode. • LF (Line Feed) - Moves the cursor down a line after each decode. • CR & LF - Allow you to select where the cursor on a display terminal returns to after it displays each decoded symbol. Selecting both CR and LF returns the cursor to the same position on successive lines after each decode. If you select no control code, the cursor remains where it stopped after the last transmission. • HT (Horizontal Tab) - Moves the cursor one tab space. • End -of-text <ETX> - One or two characters, user-defined. Refer to the
ASCII Character table in Appendix A for more information.
Suffix None
Suffix ETX
Suffix CR
Suffix CR/LF
Suffix LF
Suffix HT
User’s Choice Suffix Character 1
User’s Choice Suffix Character 2
4-31
Page 76
LS 1000 Series Product Reference Guide
Prefix/Suffix Values
0
1
2
3
4
5
6
7
8
9
CANCEL
4-32
Page 77
Programming the LS 1004
RS-232C Baud Rate Baud Rate is the number of bits of data transmitted per second. The unit’s baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device, or may reach it in distorted form.
2400
300
4800
600
1200
9600
19200
4-33