The text of a manual · part 8 of 25
Series 3800 Product Reference Guide, pages 42 to 52
Pages 42 to 52 of 138: Standard Spectrum24 Software; Initializing the Series 384X
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LRT-3800 and Symbol LRT-3824
Page 42
Series 3800 Product Reference Guide
Standard Spectrum24 Software The Series 384X comes with the system software installed, including: ! ! ! !
Spectrum24 radio drivers TCP/IP software configuration files various utilities.
A BIOS of version 1.09 or later is required. The default files cover most expected installations/initializations with minor changes as detailed in this chapter. If your requirements are more advanced, refer to the Spectrum24 Network Development Kit documentation for more information on the Spectrum24 RF network, SLAODI.COM, the Symbol-provided ODI driver, and the configuration file setups required for various platforms.
Boot Options & Internet Addressing Each Series 384X requires a unique internet address (IP address), allowing messages it sends and receives to be correctly routed over networks conforming to the TCP/IP protocol standards. These addresses can be administered and entered manually, or administered and allocated by a server on the network. By default, the Series 3800 uses NOBOOT (manual entry) to define the IP address. To set the IP address, use the CFG24 utility described later in this chapter in the section Initializing the Series 384X. Two protocols are defined for the IP address allocation on the network: BOOTP and DHCP. To allocate IP addresses through a BOOTP or DHCP server, you must change the boot option in the configurator using the Boot Mode parameter.
4-2
Page 43
Spectrum24 Terminal Setup
Initializing the Series 384X To initialize a Series 384X which has LWP.HEX version 3.03 or greater loaded: Note: This section covers specific settings required on first booting the Series 384X out of the box. For a complete review of the CFG24 screens, refer to Appendix E, Spectrum24 Utilities. 1. Insert a charged battery in the Series 384X. Refer to Chapter 6 for instructions on charging and installing a battery. 2. Cold boot the Series 384X. For the 35-key 384X: "
Press and hold < # + SPACE + FUNC>. Press and release PWR. " Release <# + SPACE + FUNC>. "
For the 46-key 384X: "
Press and hold <A + B + D>. " Press and release PWR. " Release <A + B + D>. 3. The Series 384X loads software, then brings up the Spectrum24 Configurator (CFG24) menu, shown in Figure 4-1. Note: CFG24 comes up automatically after the first initialization out of the box. On subsequent initializations, type CFG24 at the DOS prompt to bring up the configurator.
4-3
Page 44
Series 3800 Product Reference Guide
CONFIGURATOR 1.XX View config params Net Id Subnet Mask Default Router Terminal IP Address Diversity Terminal Sleep Mode Boot Mode Power Management Exit #$, Clear, Enter
Figure 4-1. CFG24 Main Menu On the Series 384X screen, the top and bottom lines of the menu are displayed, and the remaining lines are viewed by scrolling. In this menu, pressing <CLEAR> has the same effect as selecting Exit. 4. The Series 384X initially is set to NOBOOT mode. To configure the terminal for operation, set up the parameters provided in Table 4-1 (the procedures are detailed in the steps below). Table 4-1. Spectrum24 Configuration Parameters
4-4
Net Id
The Net Id identifies the radio network and differentiates between different radio networks. All equipment on one network must use the same Net Id. Set to the same value specified for the Spectrum24 Access Points (APs).
Boot Mode
The boot mode indicates the source of the terminal’s IP address. If this value is set to “Manual entry”, you must enter a terminal IP address through CFG24.
Page 45
Spectrum24 Terminal Setup
Table 4-1. Spectrum24 Configuration Parameters (Continued) Terminal IP Address
Required if you are not using a boot server to allocate IP addresses (BOOTP or DHCP). Set as advised by your LAN administrator. Note: Take care entering this value! The IP address must be unique in the network or communications will be unpredictable.
Subnet Mask
Set as advised by your LAN administrator. Note: If you change boot mode, the value set by a server overrides this value.
Default Router
The default router is the address of the node where all packets destined for remote networks will be sent. Set as advised by your LAN administrator. Note: If you change boot mode, the value set by a server overrides this value.
Diversity
Determines whether the radio firmware attempts to use one or two antenna ports for communications. It is important to match this setting with the actual number of antennas in use. If set to “Yes”, the radio firmware attempts to use both antenna ports for communications. The Series 384X has two antennas. Set to “Yes”.
Terminal Sleep Mode
Determines whether radio is powered off after the terminal enters sleep mode due to inactivity. Refer to Appendix E for more information. The default value is “On”.
Power Management
If power management is set toPSP, the radio powers up only when there is traffic on the network. If it is set to CAM, the radio is always ready to receive. Use the PSP setting to save battery life. The default value is “PSP”.
a. To view the Series 384X’s default parameters, select VIEW CONFIG PARAMS (Figure 4-2).
4-5
Page 46
Series 3800 Product Reference Guide
This screen is for display only; it is not a data entry screen. Use it to review the terminal’s IEEE (or MAC) address, IP address, and Net Id. Press <CLEAR> or <ENTER> to return to the main menu. VIEW CONFIG PARAMS Terminal IEEE addr 00:a0:f8:00:02:b8 Terminal IP Address 157.235.93.186 Net Id = 150 #$, Clear, Enter
Figure 4-2. View Configuration Parameters Screen b. To change the Net Id, select Net Id from the CFG24 Menu. The Net Id screen (Figure 4-3) is displayed. NET ID Enter Net Id(hex): 150
BkSp, Clear, Enter
Figure 4-3. Net Id Screen To change the current Net Id value, backspace over the current value and type a new value, in hexadecimal format, in the range 101 to 1FE. Alphabetical hex values can appear in upper or lower case. The default value is 101. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-6
Page 47
Spectrum24 Terminal Setup c. Select Subnet Mask from the main configuration menu. The Subnet Mask screen (Figure 4-4) is displayed. SUBNET MASK Enter Subnet Mask: 255.255.255.0
Bksp, Clear, Enter
Figure 4-4. Subnet Mask Screen To change the current Subnet Mask setting, backspace over the current value and type a new value, in decimal form. Each part of the four-part address must be in the range 0 to 255. The default value is 255.0.0.0. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. d. Select Default Router from the main configuration menu. The Default Router screen (Figure 4-5) is displayed. DEFAULT ROUTER Enter Default Router 157.235.93.178
BkSp, Clear, Enter
Figure 4-5. Default Router Screen To change the current Default Router setting, backspace over the current value and type a new value, in decimal form. Each part of the four-part address must be in the range 0 to 255. The default value is 0.0.0.0. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-7
Page 48
Series 3800 Product Reference Guide e. Select Terminal IP Address from the main configuration menu. The Terminal IP Address screen (Figure 4-6) is displayed. TERMINAL IP ADDRESS Enter IP address: 157.235.93.186
BkSp, Clear, Enter
Figure 4-6. Terminal IP Address Screen To change the current Terminal IP Address, backspace over the current value and type a new value in decimal form. Each part of the four-part address must be in the range 0 to 255. The default value is 0.0.0.0. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. f. Select Diversity from the main configuration menu. The Diversity screen (Figure 4-7) is displayed. DIVERSITY 2 antennas (Yes/No) Yes
#$, Clear, Enter
Figure 4-7. Diversity Screen To change the current Diversity setting, use the #$ cursor keys to toggle between the settings “Yes” and “No”. For the Series 384X, set Diversity to “Yes”. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-8
Page 49
Spectrum24 Terminal Setup g. Select Terminal Sleep Mode from the main configuration menu. The Terminal Sleep Mode screen (Figure 4-8) is displayed. TERMINAL SLEEP MODE Radio state: On
#$, Clear, Enter
Figure 4-8. Terminal Sleep Mode Screen To change the current Terminal Sleep Mode, use the #$ cursor keys to toggle between the “On” and “Off” settings. The default setting is “On”. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. h. Select Boot Mode from the main configuration menu. The Boot Mode screen (Figure 4-9) is displayed. BOOT MODE IP address from: Manual entry
#$, Clear, Enter
Figure 4-9. Boot Mode Screen To change the current boot mode, use the #$ keys to toggle among the three settings: “Manual entry”, “BOOTP”, and “DHCP”. Refer to Appendix E for a complete explanation of the three boot modes. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes.
4-9
Page 50
Series 3800 Product Reference Guide i. Select Power Management from the main configuration menu. The Power Management screen (Figure 4-10) is displayed. POWER MANAGEMENT Radio Power Mode PSP
#$, Clear, Enter
Figure 4-10. Power Management Screen To change the current power management mode, use the #$ keys to toggle between the settings “PSP” and “CAM”. The default setting is “PSP”. Press <ENTER> to effect the change. Press <CLEAR> to exit without changes. 5. When all of your changes are made, press < CLEAR> to return to the main configuration menu. 6. Select Exit from the main configuration menu and press <ENTER> to exit the configurator. The Series 384X displays the message: ...updating config data and proceeds with the initialization which writes the configuration values to a R/W non-volatile section of radio flash memory.
4-10
Page 51
Spectrum24 Terminal Setup
Initiating Network Connection As the initialization continues, the terminal attempts to associate with the Spectrum24 AP using the default or newly entered Net Id.
Series 384X Association with AP Not Successful If the Series 384X is unable to associate with the AP (the Net Id is wrong or forgotten), it displays the message: STAT24 Ver 1.XX NOT Associated for a few seconds. A second message follows: Terminal cannot associate with AP. You’re out of range or not configured. Ctrl+C to end or other key to retry. Strike any key when ready.....
The Series 384X continues trying to connect until the attempt is cancelled. 1. Press <Ctrl + C> to end the attempt. The Series 384X displays the message: Halt Batch process Y/ N?
2. Type Y to exit to the DOS prompt (D:). 3. At the DOS prompt, type CFG24 and press <ENTER> to initiate the Configurator and bring up the Configurator screen. 4. Verify the Net Id with the LAN administrator to ensure you are entering the correct value. 5. Verify other parameters and proceed as directed in the section Initializing the Series 384X, beginning with step 4a.
Series 384X Association with AP Successful If the association is successful, the terminal begins operating using the software files loaded on the flash disk. On first initialization, you probably don’t have applications loaded. Proceed with loading the applications as directed in Installing Application Software on Flash Disk. On subsequent initializations, if only one application is loaded, that application is displayed automatically.
4-11
Page 52
Series 3800 Product Reference Guide
If you loaded multiple applications, a application selection menu is displayed early in the initialization process. Select the application to load for the current session and proceed.
4-12