For the Symbol LRT-3800 and Symbol LRT-3824

Page 37

Batch and Spectrum One Terminal Setup

Loading the Program To download the program, initiate the communications software on the host computer and terminal as described in the following sections. Note: Communications parameters specified on the host and the terminal must match. These parameters typically are: 38400 bps 7-bit parity Odd parity Xon/Xoff flow control To program the EEPROM, the terminal must be connected to the host through a cradle, 3860 CCM, or PC Adapter with PIM.

Initiate Host Communications Software Note: To cancel communications at any time during the session, press CLEAR on the terminal. The session stops immediately. 1. Power on the host computer. 2. Start the communications program. 3. Enter the SENDHEX command. sendhex pgmname 38400 com2 where: SENDHEX is the command pgmname is the application being loaded (.hex extension is optional)

parameters

Communications parameters follow the program name. Parameters include baud rate, communications port, data bits, parity, and flow control. To accept the default parameters, do not enter a value.

In the example, the baud rate is set to 38400 bps and the communications port to COM2. The default values are accepted for the remaining parameters. 3-3

Page 38

Series 3800 Product Reference Guide

Note: Versions of SENDHEX earlier than 3.0 do not support flow control. If you use an earlier version and encounter communication errors, use a lower baud rate. 4. SENDHEX displays the prompt: Press <Enter> to begin communications.

5. Do NOT press <ENTER> yet. Before starting communications (refer to Starting Communications), set up the terminal as directed in Initiate Terminal Communications.

Initiate Terminal Communications 1. Boot the terminal to command mode. Refer to Chapter 5, Operating the Series 3800, for a list of the boot to command mode sequences. The terminal displays the following: COMMAND MODE Select function Self test

2. Scroll through Command Mode options using UpArrow or DownArrow until "Program loader" is displayed. Press <ENTER>. 3. The terminal displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>

Before loading the new application, erase the NVM’s original contents. Note: To cancel this operation, press <CLEAR>. 4. Press <ENTER> to erase the EEPROM. Wait while the EEPROM is erased. When complete, the program prompts for the communications parameters.

3-4

Page 39

Batch and Spectrum One Terminal Setup

5. Baud Rate.The terminal displays: Comm Parameters Baud 4 9600

Scroll through the list using UpArrow or DownArrow. When the correct rate is displayed (38400 is recommended), press <ENTER>. 6. Data Bits. The terminal displays: Comm Parameters Data Bits 7

Press <7> (recommended) or <8> to specify data bits, or scroll through the list using UpArrow and DownArrow. Press <ENTER> when the correct value is displayed. Note: If 8 data bits is selected, the program selects "No parity" and skips the next step. 7. Parity. If 7 data bits is selected, the terminal displays: Comm Parameters Parity Odd

Press the first letter of a parity option (Even, Odd, None, Space, or Mark), or scroll using UpArrow and DownArrow and press <ENTER> when the correct value is displayed. 8. Flow Control. The terminal displays: Comm Parameters Flow Control None

Press the first letter of a flow control option (None, Xon/Xoff, or RTS/CTS), or scroll using UpArrow or DownArrow and press <ENTER> when the correct value is displayed.

3-5

Page 40

Series 3800 Product Reference Guide

Starting Communications 1. The terminal is ready to receive the program from the host PC and displays: Comm Parameters Start? <ENT>

2. Press <ENTER> on the terminal. 3. Press <ENTER> on the host computer. SENDHEX begins transmitting the program image. When communications are established, the terminal displays: Program loader Receiving: XXXX

During program loading, the display shows the program segment address being transferred (XXXX). 4. When the transmission is complete, the terminal displays: Program loader Status 0000

A status of 0000 (all zeros) indicates a successful transter. Other status values indicate an error. These values are provided in Appendix B, Communications Status Codes. If you received an error, press <Clear> on the terminal to return to the Command Mode main menu.

Ending Communications To return to the Command Mode main menu: 1. Press <Clear> on the terminal. 2. Power down the terminal. 3. Detach any cables connected to the terminal. 4. Reboot the terminal using the appropriate cold boot sequence described in Chapter 5, Operating the Series 3800, in the section Booting a Series 3800 Terminal .

3-6

Page 41

Chapter 4 Spectrum24 RF Terminal Setup Spectrum24 Terminals In Spectrum24 terminals, wireless connectivity is accomplished using standard communications protocols. Because they are standard, the protocols are generalized and take up considerably more space on the terminal’s NVM than was required for Spectrum One ® terminals. Because there is less space available in NVM for application files, the terminal operates with an additional megabyte of non-volatile memory or flash disk. This extra memory is used to reduce not only the boot times but also the time and resources required to load applications into the terminal. The flash disk also offers the possibility of running multiple applications from the same terminal (refer to the section Multiple Applications on the Same Terminal for more information. With version 3.03 or later of the system software (LWP.HEX), the terminal can also run diagnostic tools.

Accessing the Flash Disk The flash disk is accessed through a driver, FLASHDSK.SYS, which makes the flash disk appear to a program as another disk drive (E:). The drive has characteristics of fast reading but slow writing (e.g., even for the smallest files, the write process takes 3-4 seconds). These characteristics make it ideal for files that are written once, accessed often, and seldom updated. We recommend that you use the flash disk (E:) mainly for application and configuration file storage. To avoid overwriting the flash disk by mistake, the flash disk is set to read-only mode for normal operation. The software installation or application software takes care of write/ read mode switching for you.

4-1