Page 110

Series 3800 Product Reference Guide

Scanning Standard 1-D Scan Element Table C-2. Standard 1-D Scan Element Specifications Item

Description

Power Requirements

3.0 to 5.5 VDC; 60 mA typ @Vcc; 70 mA max

Surge Current

60 mA typical @ 5.5 VDC; duration, 16 mSec

Cold Standby Current

50 mA

Max Vcc Noise Level

100 mV p to p

Scan Repetition Rate

36 (± 3) scans/sec (bidirectional)

Laser Power

.9 mW max

Skew Tolerance

± 65o from normal

Pitch Angle

± 55o from normal

Specular Dead Zone

±2o

Decode Depth of Field

Minimum element resolution is 5 mils (.127 mm) Max Typical working distance is 34 in. (86 cm)

Print Contrast Minimum

20% absolute dark/light reflectance differential, measured at 675 nm.

Ambient Light Immunity

Immune to direct exposure from normal office and factory level light

Sunlight

8000 ft. candles; 86,112 lux with correct enclosure

Artificial Light

150 ft. candles; 1615 lux

Shock

1500 G applied via any mounting surface @23o C

Vibration

Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr. per axis, over a frequency range of 5 Hz to 2000 Hz.

Operating Temperature

-4° to 122° F; -20° to 50° C

Storage Temperature

-40° to 140° F; -40° to 60° C

Humidity

5% to 95% non-condensing

Height

0.76 in. max.; 1.93 cm

Width

1.60 in. max.; 4.1 cm

Length

1.49 in. max.; 3.8 cm

Weight

1.70 oz. max.; 48 gm

C-2

Page 111

Appendix D Boot-Up Quick Reference

Table D-1. 35-Key Boot Procedures Boot Type

Key Sequence

Used For

Results

Power On

PWR or Laser Trigger or remove terminal from cradle

Normal power on

Returns terminal to where it was when it was turned off.

Warm Boot

+ / PWR

Lets you choose a program that resides in NVM.

If system software is present, returns terminal to DOS. Otherwise, returns terminal to command mode. Retains contents of RAM.

Cold Boot

SPACE FUNC

Resetting BIOS and Erases and recreates RAM disk. Only data in NVM is retained. the operating system.

Command Mode Start

BKSP Shift PWR

Entering command Takes terminal to beginning of mode for self-test or command mode. The first time you turn the terminal on or after the communication terminal has been stored without batteries, acts the same as a Cold Boot (resets BIOS, loses contents of RAM).

D-1

Page 112

Series 3800 Product Reference Guide

D-2

Page 113

Appendix E Spectrum24 Network and Flash Disk Utilities Introduction Some supplemental utilities are provided for working with the flash disk in addition to the Flash disk driver and utilities described in the Series 3000 ADK (refer to the section on FLASHDSK.SYS in the Device Driver chapter of the Series 3000 Application Programmer’s Reference Manual. These utilities include: CFG24 executes from a DOS prompt to change parameters for radio communications.

DIAG24 executes from a DOS prompt to test radio connectivity and performance.

BOOTP is automatically executed by the start-up procedure. Obtains IP address and sets up communications parameters. Should NOT be executed from a DOS prompt.

STAT24 is automatically executed by the start-up procedure. Indicates the status of the radio connection. Should NOT be executed from a DOS prompt.

FLASH.BAT facilitates performing flash disk housekeeping functions, such as copying files to, deleting files from, and renaming files on the flash disk. Executes from a DOS prompt.