The text of a manual · part 21 of 25
Series 3800 Product Reference Guide: Scanning
Pages 110 to 113 of 138, from Series 3800 Product Reference Guide
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LRT-3800 and Symbol LRT-3824
Page 110
Series 3800 Product Reference Guide
Scanning Standard 1-D Scan Element Table C-2. Standard 1-D Scan Element Specifications Item
Description
Power Requirements
3.0 to 5.5 VDC; 60 mA typ @Vcc; 70 mA max
Surge Current
60 mA typical @ 5.5 VDC; duration, 16 mSec
Cold Standby Current
50 mA
Max Vcc Noise Level
100 mV p to p
Scan Repetition Rate
36 (± 3) scans/sec (bidirectional)
Laser Power
.9 mW max
Skew Tolerance
± 65o from normal
Pitch Angle
± 55o from normal
Specular Dead Zone
±2o
Decode Depth of Field
Minimum element resolution is 5 mils (.127 mm) Max Typical working distance is 34 in. (86 cm)
Print Contrast Minimum
20% absolute dark/light reflectance differential, measured at 675 nm.
Ambient Light Immunity
Immune to direct exposure from normal office and factory level light
Sunlight
8000 ft. candles; 86,112 lux with correct enclosure
Artificial Light
150 ft. candles; 1615 lux
Shock
1500 G applied via any mounting surface @23o C
Vibration
Withstands a sinusoidal vibration of 1 G along each of the 3 mutually perpendicular axes for a period of 1 hr. per axis, over a frequency range of 5 Hz to 2000 Hz.
Operating Temperature
-4° to 122° F; -20° to 50° C
Storage Temperature
-40° to 140° F; -40° to 60° C
Humidity
5% to 95% non-condensing
Height
0.76 in. max.; 1.93 cm
Width
1.60 in. max.; 4.1 cm
Length
1.49 in. max.; 3.8 cm
Weight
1.70 oz. max.; 48 gm
C-2
Page 111
Appendix D Boot-Up Quick Reference
Table D-1. 35-Key Boot Procedures Boot Type
Key Sequence
Used For
Results
Power On
PWR or Laser Trigger or remove terminal from cradle
Normal power on
Returns terminal to where it was when it was turned off.
Warm Boot
+ / PWR
Lets you choose a program that resides in NVM.
If system software is present, returns terminal to DOS. Otherwise, returns terminal to command mode. Retains contents of RAM.
Cold Boot
SPACE FUNC
Resetting BIOS and Erases and recreates RAM disk. Only data in NVM is retained. the operating system.
Command Mode Start
BKSP Shift PWR
Entering command Takes terminal to beginning of mode for self-test or command mode. The first time you turn the terminal on or after the communication terminal has been stored without batteries, acts the same as a Cold Boot (resets BIOS, loses contents of RAM).
D-1
Page 112
Series 3800 Product Reference Guide
D-2
Page 113
Appendix E Spectrum24 Network and Flash Disk Utilities Introduction Some supplemental utilities are provided for working with the flash disk in addition to the Flash disk driver and utilities described in the Series 3000 ADK (refer to the section on FLASHDSK.SYS in the Device Driver chapter of the Series 3000 Application Programmer’s Reference Manual. These utilities include: CFG24 executes from a DOS prompt to change parameters for radio communications.
DIAG24 executes from a DOS prompt to test radio connectivity and performance.
BOOTP is automatically executed by the start-up procedure. Obtains IP address and sets up communications parameters. Should NOT be executed from a DOS prompt.
STAT24 is automatically executed by the start-up procedure. Indicates the status of the radio connection. Should NOT be executed from a DOS prompt.
FLASH.BAT facilitates performing flash disk housekeeping functions, such as copying files to, deleting files from, and renaming files on the flash disk. Executes from a DOS prompt.
E-1