Page 104
Series 3800 Product Reference Guide
Scanning Problems What If... Nothing happens when you follow the operating instructions? ! ! ! ! !
Check the system power. Verify that the scanner is programmed to read the symbology you are trying to read. Try scanning a test symbol of the symbology you are trying to read. Check the bar code to ensure that it is not defaced. A defaced bar code may not be readable. Check to see that you are scanning from the proper distance.
Your terminal operates but scanned data is not displayed correctly? ! !
Check the system power. Check that the communications parameters (baud rate, parity, stop bits, etc.) are set properly for the receiving device.
The laser does not activate? !
!
7-14
You may have exceeded the allowable amount of scanning activity within the limits of your laser class of operation; in this case, wait for a short interval before scanning again. You may be scanning in an inappropriately hot environment. If so, remove the equipment from the environment or allow the laser to cool down.
Page 105
Appendix A Null Modem Pin-outs Null Modem Pin-Outs for Full Duplex Use the pin-outs shown in Figure A-1 for null modem communication.
PG
1
1
PG
TD
2
2
TD
RD
3
3
RD
RTS
4
4
RTS
CTS
5
5
CTS
DSR
6
6
DSR
SG
7
7
SG
DCD
8
8
DCD
DTR
20
20 DTR
Figure A-1. Null Modem Pin-Outs - Full Duplex
A-1
Page 106
Series 3800 Product Reference Guide
Null Modem Pin-outs for Half-Duplex Use the pin-outs shown in Figure A-2 for testing.
PGND 1
1
PGND
TD
2
3
RD
RD
3
2
TD
RTS 4
8
DCD
DSR 6
20
DTR
SG
7
7
SG
DCD 8
4
RTS
5
CTS
6
DSR
CTS 5
DTR 20
Figure A-2. Null Modem Pin-Outs - Half Duplex
A-2
Page 107
Appendix B Communications Status Codes The program loader status code consists of four hexadecimal digits which indicate whether or not the transfer was successful, and if not, the source of the communications error. A status code of 0000 indicates success; any other code indicates failure. Table B-1 lists the failures associated with the status codes. The values are additive. Table B-1. Communications Status Codes Status Code
Meaning
0002
Receive overrun error
0004
Receive parity error
0008
Receive framing error
0010
Programming voltage not present
0020
Data Set Ready or Carrier Detect not detected on open
0080
ABORT key hit during comm
0100
Insufficient NVM for image
0200
Illegal Intel hexadecimal record
0400
Unsupported Intel record
0600
NVM EEPROM failed to erase
0800
Receive time-out error
1000
Control start character time-out
2000
Clear To Send inactive time-out error
4000
Receive buffer full
B-1
Page 108
Series 3800 Product Reference Guide
B-2
Page 109
Appendix C Specifications Environment The terminal’s operating conditions are listed in Table C-1, Environmental Specifications. Table C-1. Environmental Specifications Condition
Range
Operating Temperature
-9°F to 104°F (-23°C to 40°C)
Storage Temperature
-4°F to 140°F (-20°C to 60°C)
Humidity (Operating)
0 to 90% (noncondensing)
Altitude
Up to 10,000 feet
Static
Up to 15 KV (terminal power may go off)
Shock
Withstands multiple 4-foot drops to concrete without malfunction or loss of data
Note: Batteries lose power faster at extremely high and low temperatures, and at temperatures below 0oC, the LCD operates slowly.
C-1