Page 81

Maintaining the Series 3800

NiCd Battery Pack Replacement Battery Packs NiCd battery packs available from Symbol are listed below. System

P/N

Battery Pack

Standard

3872-103

NiCd Rechargeable

LRT Intrinsically Safe

3872-115

6-Cell NiCd

LDT Intrinsically Safe

3872-105

5-Cell NiCd

Note: Do not use the standard NiCd Battery (P/N 3872-103) with the LRT 3800 intrinsically safe terminals.

Removing the NiCd Battery Pack WARNING This procedure is not approved for, and should not be performed in, potentially hazardous environments. To remove the battery pack (refer to Figure 6-1): 1. Power the terminal off.

Figure 6-1. Removing the Battery Pack

6-3

Page 82

Series 3800 Product Reference Guide

2. Twist the D-ring on the bottom of the handle 90 degrees counterclockwise and remove the end cap. The battery pack should drop out. If necessary, tap the terminal against your hand gently to dislodge the battery.

Caution If you intend to store your terminal without the battery pack, ensure you have stored any data and/or programs you wish to keep on another terminal, a host computer, or another medium to avoid loss of data. The terminal backup power source retains data for approximately 15 minutes after the battery pack is removed, as long as the lithium backup batteries remain in place.

Installing the NiCd Battery Pack WARNING This procedure is not approved for, and should not be performed in, potentially hazardous environments. 1. Insert the batterypack into the battery compartment in the handle of the terminal. 2. Replace the end cap and twist the D ring halfway clockwise to lock it. 3. Press the D-ring flat to secure it.

6-4

Page 83

Maintaining the Series 3800

Charging the NiCd Battery Pack WARNING This procedure is not approved for, and should not be performed in, potentially hazardous environments. The NiCd battery pack automatically charges when the terminal is placed in a cradle or connected to a PC Adapter. A full charge takes about 7 hours. We recommend that you always keep the NiCd battery pack fully charged.

Battery Charging in the Terminal Using a Cradle To charge a NiCD battery in the terminal, using the 3860, 3865, or 3866 cradle (Figure 6-2): 1. Place the terminal in the cradle. The cradle charging light flashes when charging a discharged battery and remains steady when trickle-charging a charged battery.

3860

3865

3866

Figure 6-2. Charging the Battery in the Cradle 2. Leave the terminal up to 8 hours to recharge a fully discharged battery.

6-5

Page 84

Series 3800 Product Reference Guide

Charging Battery Packs Outside the Terminal Slots are provided in 3860 and 3865 cradles to charge spare battery packs outside the terminal. Place the battery pack to be charged in one of the battery slots in the cradle. The LED indicator lamp under the battery slot in which the terminal was placed indicates the battery is charging. (On the 3860, the spare-battery-charging indicator lamp is the right hand of three.) If the lamp is off, charging is not occurring. A blinking LED indicates fast charge; a solid on LED means slow charge/ready. See the cradle documentation listed in Related Publications for details.

Caution The optional communications cradles are NOT certified for use in potentially hazardous environments. To charge an intrinsically safe LRT 3800 in a cradle, remove the terminal from the potentially hazardous environment before charging.

Battery Charging with the PC Adapter Refer to Chapter 2, Hardware Setup, for instructions on setting up the PC Adapter for charging. Battery charging begins automatically when power is supplied to the PC Adapter. Fully charging a battery using the PC Adapter requires 14 hours.

Other Charging Options You have the option of charging battery packs in the UBC 1000 Charger. Refer to the UBC 1000 Charger documentation for more information.

6-6

Page 85

Maintaining the Series 3800

Battery Charging Tips For maximum capacity and battery life, follow these helpful hints:

Do ! ! ! ! !

Charge at temperatures between 0°C and 38°C (32°F to 100°F); 21°C (70°F) is preferred Recharge as soon as you see the “Low Battery” message Save your data and program on another terminal or another medium if you plan to store your terminal without the primary battery pack Store batteries at room temperature of 21°C (70°F) or cooler Recharge the NiCd battery pack after storage.

Don't ! !

Store or recharge primary batteries at temperatures below 0°C (32°F) or above 38°C (100°F) Judge a battery's charge level by measuring its voltage; voltage does not indicate charge level.

6-7