The text of a manual · part 13 of 25
Series 3800 Product Reference Guide: Scanning
Pages 76 to 80 of 138, from Series 3800 Product Reference Guide
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LRT-3800 and Symbol LRT-3824
Page 76
Series 3800 Product Reference Guide
Scanning Before scanning can occur, the terminal must be running an application that supports bar code scanning. The terminal must also be programmed to scan the type of bar code you want, such as Universal Product Code (UPC) or Code 3 of 9. For information on scanning applications and on programming the scanner, refer to the Series 3000 ADK.
Entering Data Using the Laser Scanner 1. Pull the trigger on the terminal handle to power on the terminal and laser scanner. 2. Hold the terminal within the specified range of distance from and at a slight angle to the bar code you wish to scan and pull the trigger. 3. Adjust the aim so that the thin, red laser beam covers the entire length of the bar code. Do not hold the scanner directly over the bar code. The larger the bar code, the farther away you should hold the scanner.
Wrong
Right
Optimal scanning distance varies with bar code density and scanner optics, but more combinations work within 4 to 10 inches. 4. If the decode is successful, the screen displays the code and the green LED flashes. The terminal may also beep. Note: The procedure for your scanner may differ from the one given above. Scanner use depends on the application.
Scanning Considerations Usually, scanning is a simple matter of aim, scan, and decode, and a few quick trial efforts master it simply and intuitively. However, two important considerations can optimize any scanning technique, angle and range.
5-14
Page 77
Operating the Series 3800
Angle Scanning angle is important for promoting quick decodes. When laser beams reflect directly back into the scanner from the bar code, this specular reflection can actually “blind” the scanner. To avoid this, scan the bar code so that the beam does not bounce directly back. But don’t scan at too oblique an angle; the scanner needs to collect scattered reflections from the scan to make a successful decode (refer to Figure 5-3). Practice quickly shows what tolerances to work within.
Tilt back at slight angle.
Specular Reflection
No Specular Reflection
Reflected beam interferes
Decode can occur
Bar Code
Bar Code
Figure 5-3. Scanning Angle and Specular Reflection
5-15
Page 78
Series 3800 Product Reference Guide
Range Any scanning device decodes well over a particular working range, minimum and maximum distances from the bar code. This range varies according to bar code density and scanning device optics. Scanning within range brings quick and constant decodes; scanning too close or too far away prevents decodes. You need to find the right working range for the bar codes you are scanning. The best general advice is: !
Hold the scanner farther away for larger symbols.
!
Hold the scanner closer for symbols with bars that are close together. Start scanning at a distance from the bar code, not from direct contact. If the bar code does not readily decode, move the scanner in closer. Practice quickly shows what distances to work within.
! !
Communications For communications with a host or printer: 1. Set up the 3860 CCM, 3865/3866 cradle(s), or PC adapter as described in Chapter 2, Hardware Setup. 2. Place the terminal in the CCM or cradle, or attach the terminal to the PC adapter as described in Chapter 2, Hardware Setup. 3. Start the communications program on the host and terminal.
5-16
Page 79
Chapter 6 Maintaining the Series 3800 Batteries The Series 3800 terminal is powered by a rechargeable nickel cadmium (NiCd) battery pack or one 9-volt alkaline battery installed in the alkaline battery adapter. Fully charged, the NiCd battery pack provides up to 8 hours of continuous operation. The NiCd battery pack is recharged by: ! ! !
placing a 3800 with the battery installed in a 3860, 3865, or 3866 cradle for 7 hours, or by connecting the terminal to a PC Adapter, or by placing the battery pack in a battery slot on the 3860 or 3865. Note: The terminal can be used while the battery is being charged in the 3860 CCM or connected to the PC Adapter.
Battery Life Battery life is affected by many factors, including ! ! ! ! !
scanning radio communications very high or very low operating temperatures backlighting use battery age. 6-1
Page 80
Series 3800 Product Reference Guide
When to Replace or Recharge the Battery The Series 3800 terminals provide two types of indicators to notify you when battery power is running low: warning messages and modified cursors. These indicators may be changed or disabled by an application. !
!
LOW BATTERY - When the battery is low, the cursor changes as shown in Table 61. If ERR300 is loaded, the message LOW BATTERY also appears. At this level the terminal continues to operate, but there is probably less than 1 hour of usable power left. VERY LOW - When the power is very low, the REPLACE CELLS message appears and the system powers off. Replace an alkaline battery or recharge a NiCd battery before attempting to use the terminal. If the battery is not immediately recharged or replaced, data may be lost. Table 6-1. Cursor Indicators Keyboard State
Cursor Character
Low Battery
Unshifted
(inverted caret)
(inverted solid caret)
Shifted
(caret)
(solid caret)
Momentary Shifted
(up arrow)
(solid up arrow)
Momentary Unshifted
(down arrow)
(solid down arrow)
(underline c)
(inverse c)
(underlined f)
(inverse f)
Control Function c f
Backup Batteries To prevent data loss during battery replacement, the terminal utilizes a lithium battery as a backup. The backup battery provides sufficient power to preserve memory contents for approximately 15 minutes while the primary battery is replaced. The backup battery does not provide enough power to operate the terminal. On receiving a low battery message, replace or recharge the primary batteries immediately.
6-2