Page 47
Chapter 4 User Preferences & Miscellaneous Digital Imager Scanner Options Introduction You can program the digital imager scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides programming bar codes for selecting these features. The digital imager scanner ships with the settings shown in Table 4-1 on page 4-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when you power down the digital imager scanner. NOTE
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.
If not using a USB cable, select a host type after the power-up beeps sound. See Chapter 6, SSI Interface Chapter 7, USB Interface and Chapter 8, RS-232 Interface for specific host information. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*High Volume
Feature/Option
(00h) Option Hex Value for programming via SSI command
Page 48
4-2
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-5. The digital imager scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences and Miscellaneous Options - Parameter Defaults Table 4-1 lists defaults for user preferences parameters. There are two ways to change the default values:
• Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, see the Set Default Parameter on page 4-4.
• Download data through the device’s serial port using SSI. Hexadecimal parameter numbers appear in this chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters using this method. NOTE
Table 4-1
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
User Preferences Parameter Defaults Parameter
Parameter Number
Default
Page Number
User Preferences Set Default Parameter
Restore Defaults
4-4
Parameter Scanning
ECh
Enable
4-5
Beeper Tone
91h
Medium
4-5
Beeper Volume
8Ch
High
4-6
Power Mode
80h
Continuous On
4-6
Time Delay to Low Power Mode
92h
1 Minute
4-7
Trigger Mode
8Ah
Auto Aim
4-8
Picklist Mode
F0h, 92h
Disabled Always
4-9
Decode Session Timeout
88h
9.9 Sec
4-10
Timeout Between Decodes, Same Symbol
89h
0.6 Sec
4-10
Page 49
User Preferences & Miscellaneous Digital Imager Scanner Options
Table 4-1
User Preferences Parameter Defaults (Continued) Parameter
Parameter Number
Default
Page Number
Beep After Good Decode
38h
Enable
4-11
Decoding Illumination
F0h, 2Ah
Enable
4-11
DP Illumination
F1h, 3Bh
Auto
4-12
Decode Aiming Pattern
F0h, 32h
Enable
4-13
Fuzzy 1D Processing
F1h, 02h
Enable
4-13
Decode Mirror Images
F1h, 19h
Never
4-14
Transmit Code ID Character
2Dh
None
4-15
Prefix Value
63h, 69h
7013 <CR><LF>
4-16
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah
7013 <CR><LF>
4-16
Scan Data Transmission Format
EBh
Data as is
4-17
FN1 Substitution Values
67h, 6Dh
Set
4-18
Transmit “No Read” Message
5Eh
Disable
4-19
Miscellaneous Options
4-3
Page 50
4-4
Symbol DS6707 Digital Imager Scanner Product Reference Guide
User Preferences Set Default Parameter You can reset the Symbol DS6707 to two types of defaults: factory defaults or custom defaults. Scan the appropriate bar code below to reset the scanner to its default settings and/or set its current settings as custom defaults.
• Restore Defaults - Scan this bar code to reset all default parameters as follows. • If you previously set custom defaults by scanning Write to Custom Defaults, scan Restore Defaults to retrieve and restore the scanner’s custom default settings. • If you did not set custom defaults, scan Restore Defaults to restore the factory default values listed in Table A-1.
• Set Factory Defaults - Scan this bar code to restore the factory default values listed in Table A-1. This deletes any custom defaults set.
• Write to Custom Defaults - Scan this bar code to set the current scanner settings as custom defaults. Once set, you can recover custom default settings by scanning Restore Defaults.
*Restore Defaults
Set Factory Defaults
Write to Custom Defaults
Page 51
User Preferences & Miscellaneous Digital Imager Scanner Options
4-5
Parameter Scanning Parameter # ECh To disable decoding of parameter bar codes, scan the Disable Parameter Scanning bar code below. Note that the scanner can still decode the Set Defaults parameter bar code. To enable decoding of parameter bar codes, either scan Enable Parameter Scanning or Set All Defaults.
*Enable Parameter Scanning (01h)
Disable Parameter Scanning (00h)
Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code.
Low Frequency (02h)
*Medium Frequency (Optimum Setting) (01h)
High Frequency (00h)
Page 52
4-6
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Beeper Volume Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
Low Volume (02h)
Medium Volume (01h)
*High Volume (00h)
Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In reduced power mode, the digital imager scanner enters into a low power consumption mode to preserve battery life after each decode attempt. In continuous power mode, power remains on after each decode attempt.
*Continuous On (00h)
Reduced Power Mode (01h)
Page 53
User Preferences & Miscellaneous Digital Imager Scanner Options
4-7
Time Delay to Low Power Mode Parameter # 92h NOTE
This parameter only applies when Power Mode is set to Reduced Power.
This parameter sets the time the digital imager scanner remains active after decoding. The digital imager scanner wakes upon trigger pull or when the host attempts to communicate with the digital imager scanner.
1 Second (11h)
5 Seconds (15h)
*1 Minute (21h)
5 Minutes (25h)
15 Minutes (2Bh)
1 Hour (31h)
Page 54
4-8
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Trigger Mode Parameter # 8Ah Select one of the following trigger modes for the digital imager scanner:
• Level - A trigger pull activates decode processing. Decode processing continues until the bar code is decoded, the trigger is released, or the Decode Session Timeout is reached.
• Blink - This trigger mode is used in presentation (hands-free) mode. The digital imager scanner activates decode processing when it detects a bar code in its field of view. Decoding range is reduced in this mode.
• Auto Aim - This trigger mode turns on the red laser aiming pattern when the digital imager scanner senses motion. A trigger pull activates decode processing. After 2 seconds of inactivity the red laser aiming pattern automatically shuts off.
• Host - A host command issues the triggering signal. The digital scanner interprets an actual trigger pull as a Level triggering option.
Level (00h)
Blink (07h)
*Auto Aim (09h)
Host (08h)
Page 55
User Preferences & Miscellaneous Digital Imager Scanner Options
4-9
Picklist Mode Parameter # F0h 92h Picklist mode enables the digital imager scanner to decode only bar codes that are aligned under the laser crosshair. Select one of the following picklist modes for the digital imager scanner:
• Disabled Always - Picklist mode is always disabled. • Enabled Out of Scanstand - Picklist mode is enabled when the digital imager scanner is out of presentation (scanstand) mode and disabled when the digital imager scanner is in presentation mode.
• Enabled Always- Picklist mode is always enabled.
*Disabled Always (00h)
Enabled Out of Scanstand (01h)
Enabled Always (02h)
Page 56
4 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Enter a leading zero for single digit numbers. For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on page D-2.
Decode Session Timeout
Timeout Between Decodes, Same Symbol Parameter # 89h Use this option in presentation (hands-free) mode to prevent the beeper from continuously beeping when a symbol is left in the digital imager scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.6 seconds. To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments.
Timeout Between Decodes, Same Symbol