The text of a manual · part 8 of 48
Symbol DS6707 Digital Imager Scanner Product Reference Guide: Maintenance & Technical Specifications
Pages 39 to 46 of 394, from Symbol DS6707 Digital Imager Scanner Product Reference Guide
The original document is the PDF (8.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6707
Page 39
Chapter 3 Maintenance & Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.
• Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window.
Page 40
3-2
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Troubleshooting Table 3-1 Troubleshooting
Problem The aiming pattern does not appear when pressing the trigger.
Possible Causes
Possible Solutions
No power to the digital imager scanner.
If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used.
Connect the correct host interface cable.
Interface/power cables are loose.
Re-connect cables.
Digital imager scanner is disabled.
See the technical person in charge of scanning.
If using RS-232 Nixdorf B mode, CTS is not asserted.
Assert CTS line.
Aiming pattern is disabled.
Enable the aiming pattern. See Decode Aiming Pattern on page 4-13.
Scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.
The USB bus may put the digital imager scanner in a state where power to the digital imager scanner is cycled on and off more than once.
Normal during host reset.
Digital imager scanner emits aiming pattern, but does not decode the bar code.
Digital imager scanner is not programmed for the correct bar code type.
Program the digital imager scanner to read that type of bar code. See Chapter 10, Symbologies.
Bar code symbol is unreadable.
Scan test symbols of the same bar code type to determine if the bar code is defaced.
The symbol is not completely inside aiming pattern.
Move the symbol completely within the aiming pattern.
Digital imager scanner has not completed USB initialization.
Wait several seconds and scan again.
Digital imager scanner emits 4 short high beeps during decode attempt.
Page 41
Maintenance & Technical Specifications
3-3
Table 3-1 Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
Digital imager scanner decodes bar code, but does not transmit the data to the host.
Digital imager scanner is not programmed for the correct host type.
Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.
Interface cable is loose.
Re-connect the cable.
If 4 long low beeps are heard, a transmission error occurred.
Set the digital imager scanner's communication parameters to match the host's setting.
If 5 low beeps are heard, a conversion or format error occurred.
Configure the digital imager scanner's conversion parameters properly.
If low/high/low beeps sound, an invalid ADF rule is detected.
Program the correct ADF rules.
If high/low beeps sound, the digital imager scanner is buffering Code 39 data.
Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.
Digital imager scanner is not programmed to work with the host.
Scan the appropriate host type programming bar code.
Host displays scanned data incorrectly.
For RS-232, set the digital imager scanner's communication parameters to match the host's settings. Program the proper editing options (e.g., UPC-E to UPC-A Conversion). Digital imager scanner emits high/high/high/low beeps when not in use.
RS-232 receive error.
Normal during host reset. Otherwise, set the digital imager scanner's RS-232 parity to match the host setting.
Digital imager scanner emits low/high beeps during programming.
Input error or Cancel bar code was scanned.
Scan the correct numeric bar codes within range for the parameter programmed.
Digital imager scanner emits low/high/low/high beeps during programming.
Out of ADF parameter storage space.
Erase all rules and re-program with shorter rules.
Digital imager scanner emits low/high/low beeps.
Clearing Code 39 buffer.
Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.
Digital imager scanner emits a power-up beep after changing USB host type.
The USB bus re-established power to the digital imager scanner.
Normal when changing USB host type.
Digital imager scanner emits one high beep when not in use.
In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.
Normal when Beep on <BEL> is enabled and the digital imager scanner is in RS-232 mode.
Page 42
3-4
Symbol DS6707 Digital Imager Scanner Product Reference Guide
If after performing these checks the digital imager scanner still experiences problems, contact the distributor or contact Motorola Enterprise Mobility Support. See page xv for the telephone numbers.
NOTE
Technical Specifications Table 3-2 Technical Specifications
Item
Description
Physical Characteristics Dimensions
Symbol DS6707-DP: All other models:
6.55 in. x 5.08 in. x 2.82 in. (16.6 cm x 12.9 cm x 7.1 cm) (H x L x W) 6.55 in. x 4.72 in. x 2.82 in. (16.6 cm x 11.9 cm x 7.1 cm) (H x L x W)
Weight:
Symbol DS6707-DP: All other models:
7.4 oz. (209 gm) 6.4 oz. (182 gm)
Voltage & Current:
5 +/-10%VDC @ 350 mA
Color
Cash Register White or Twilight Black (DS6707-DP is only available in Cash Register White)
Performance Characteristics Light Source
Aiming: 650 nm laser diode Illumination: 630 nm LED
Field of View (Vertical x Horizontal)
Document Capture: 35º (V) x 44º (H) Standard Range, Direct Part Mark, High Density: 34º (V) x 43º (H)
Roll Pitch Yaw
360º +/- 65º +/- 60º
Symbology Decode Capability 1D
UPC/EAN and with supplementals, Bookland EAN, Code 128, Code 128 Full ASCII, GS1-128, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 32, Code 93, Code 11, Interleaved 2 of 5, Discrete 2 of 5, Codabar (NW1), MSI, GS1 DataBar variants, IATA
Postal
US Postnet and Planet, UK Postal, Japan, Australian, Dutch, 4State Postal, Post US4
PDF417 (& Variants)
PDF417, MicroPDF417, Composite Codes
2D
Data Matrix (ECC 200), MaxiCode, QR Code, Aztec
DPM (DS6707-DP only)
Data Matrix marks applied by dot peening; laser etch, ink marks, chemical etch, inkjet mold, cast and thermal spray
Page 43
Maintenance & Technical Specifications
Table 3-2 Technical Specifications (Continued)
Item
Description
Typical Working Distance: SR - Standard Range Focus
5 mil Code 39: 10 mil I 2 of 5: 13 mil 100% UPC/EAN: 20 mil Code 39: Postnet: 6.6 mil PDF417: 10 mil PDF417: 10 mil QR Code: 10 mil MicroPDF 10 mil Data Matrix: 35 mil Maxicode:
0.9 - 5.4 in. (2.3 - 13.7 cm) 1.0 - 7.9 in. (2.5 - 20.1 cm) 0.9 - 8.4 in. (2.3 - 21.3 cm) 0.9 - 12.9 in. (2.3 - 32.8 cm) 2.6 - 12.5 in. (6.6 - 31.8 cm) 3.4 - 5.7 in. (8.6 - 14.5 cm) 1.4 - 6.2 in. (3.6 - 15.7 cm) 2.6 - 6.8 in. (6.6 - 17.3 cm) 2.3 - 7.5 in. (5.8 - 19.1 cm) 1.1 - 7.5 in. (2.8 - 19.1 cm) 1.5 - 12.8 in. (3.8 - 32.5 cm)
Typical Working Distance: DC - Document Capture focus
5 mil Code 39: 10 mil I 2 of 5: 13 mil 100% UPC/EAN: 20 mil Code 39: Postnet: 6.6 mil PDF417: 10 mil PDF417: 10 mil QR Code: 10 mil MicroPDF: 10 mil Data Matrix: 35 mil Maxicode:
2.6 - 8.4 in. (6.6 - 21.3 cm) 1.7 - 13.7 in. (4.3 - 34.8 cm) 0.9 - 14.7 in. (2.3 - 37.3 cm) 1.2 - 21.4 in. (3.0 - 54.4 cm) 2.6 - 12.5 in. (6.6 - 31.8 cm) 3.2 - 8.2 in. (8.1 - 20.8 cm) 2.4 - 11.1 in. (6.1 - 28.2 cm) 2.6 - 6.8 in. (6.6 - 17.3 cm) 2.3 - 7.5 in. (5.8 - 19.1 cm) 2.6 - 12.2 in. (6.6 - 31.0 cm) 1.5 - 12.8 in. (3.8 - 32.5 cm)
Typical Working Distance: DP - Direct Part Mark focus
3 mil Code 39: 4 mil Code 39: 5 mil Code 39: 7.5 mil Code 39: 10 mil Code 39: 20 mil Code 39: 13 mil 100% UPC/EAN: 6.67 mil PDF417: 10 mil PDF417: 15 mil PDF417: 4 mil Data Matrix: 5 mil Data Matrix: 7.5 mil Data Matrix: 10 mil Data Matrix: 4 mil QR Code: 5 mil QR Code: 7.5 mil QR Code: 10 mil QR Code:
Up to 1.21 in. (3.07 cm) Up to 1.83 in. (4.65 cm) Up to 1.96 in. (4.98 cm) Up to 2.96 in. (7.52 cm) Up to 3.50 in. (8.89 cm) Up to 6.21 in. (15.77 cm) Up to 3.59 in. (9.12 cm) Up to 1.59 in. (4.04 cm) Up to 2.21 in. (5.61 cm) 0.92 - 3.05 in. (2.34 - 7.75 cm) Up to 1.00 in. (2.54 cm) Up to 1.29 in. (3.28 cm) Up to 1.71 in. (4.34 cm) Up to 2.13 in. (5.41 cm) Up to 1.00 in. (2.54 cm) Up to 1.25 in. (3.18 cm) Up to 1.67 in. (4.24 cm) Up to 2.00 in. (5.08 cm)
3-5
Page 44
3-6
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Table 3-2 Technical Specifications (Continued)
Item
Description
Typical Working Distance: HD - High Density
3 mil Code 39: 4 mil Code 39: 5 mil Code 39: 7.5 mil Code 39: 10 mil Code 39: 20 mil Code 39: 13 mil 100% UPC: 6.67 mil PDF417: 10 mil PDF417: 15 mil PDF417: 4 mil Data Matrix: 5 mil Data Matrix: 7.5 mil Data Matrix: 10 mil Data Matrix: 4 mil QR Code: 5 mil QR Code: 7.5 mil QR Code: 10 mil QR Code:
0.84 - 2.42 in. (2.13 - 6.15 cm) 0.42 - 3.13 in. (1.07 - 7.95 cm) 0.29 - 3.38 in. (0.74 - 8.59 cm) Up to 4.38 in. (11.13 cm) 0.59 - 4.96 in. (1.50 - 12.60 cm) 0.42 - 8.21 in. (1.07 - 20.85 cm) 0.21 - 5.13 in. (0.53 - 13.03 cm) 0.63 - 3.10 in. (1.60 - 7.87 cm) 0.46 - 3.54 in. (1.17 - 9.00 cm) 1.33 - 4.46 in. (3.38 - 11.33 cm) 1.04 - 2.13 in. (2.64 - 5.41 cm) 0.79 - 2.50 in. (2.01 - 6.35 cm) 0.50 - 3.00 in. (1.27 - 7.62 cm) 0.54 - 3.50 in. (1.37 - 8.89 cm) 1.13 - 2.17 in. (2.87 - 5.51 cm) 0.88 - 2.54 in. (2.24 - 6.45 cm) 0.67 - 3.00 in. (1.70 - 7.62 cm) 0.46 - 3.42 in. (1.17 - 8.69 cm)
Print Contrast
25% minimum reflectance
Motion Tolerances
Horizontal Velocity: 5 in. (12.7 cm) per second
Interfaces Supported
RS-232C (Standard, Nixdorf, ICL, & Fujitsu) and USB (Standard, IBM SurePOS, Macintosh) allows for connectivity to all of the above plus many non-standard interfaces.
Imaging Characteristics Image (# of Pixels)
1.3 Mega Pixel: 1280 (H) x 1024 (V)
Graphics Format Support
Images can be exported as Bitmap, JPEG, and TIFF
Image Transfer Speed
USB 1.1: RS232:
Image Transfer Time
Typical USB application is ~ 0.2 seconds with a compressed JPEG of 100 kB
Imaging Distance (Vertical x Horizontal)
Documents Sizes: Minimum Distance (Approximate) 2.125 x 3.375 in. (5.4 x 8.6 cm) 2.4 in. (6.1 cm) 4 x 6 in. (10.2 x 15.2 cm) 5.7 in. (14.5 cm) 5 x 7 in. (12.7 x 17.8 cm) 11.9 in. (30.2 cm) 8½ x 11 (21.6 x 28 cm) 11.9 in. Ranges are from the nose of the scanner and are based on document capture focus only.
Up to 12 Megabits/second Up to 115 kB Baud Rate
Page 45
Maintenance & Technical Specifications
3-7
Table 3-2 Technical Specifications (Continued)
Item
Description
User Environment Operating Temperature
32º F to 104º F (0º C to 40º C)
Storage Temperature
-40º F to 158º F (-40º C to 70º C)
Humidity
5% to 95%, non-condensing
Drop Specifications
Withstands multiple 5 ft. (1.52 m) drops to concrete at operating temperature extremes, and multiple 6 ft. (1.8 m) drops to concrete at room temperature (23º C)
Ambient Light Immunity
Immune to normal artificial indoor and natural outdoor (direct sunlight) lighting.
Regulatory Electrical Safety
UL6950-1, CSA C22.2 No. 60950-1, EN60950-1 / IEC60950-1
Laser Safety
EN60825-1:1994 +A1: 2002 +A2 :2001, IEC60825-1, 21CFR1040.10 and 21CFR1040.11, CDRH Class II, IEC Class 2
EMI/RFI
FCC Part 15 Class B, ICES-003 Class B, CISPR 22, CISPR 24 Medical Electrical Equipment: EN60601-1-2: 2002
RoHS
Compliance with RoHS Directive 2002/95/EEC
Mounting Options (Accessories)
Intellistand with adjustable height: 5-10 in. (12.7-25.4 cm) and adjustable angle: 0º - 90º Desktop & Wall-mount holders are also available.
Power Supplies
Power supplies are available for applications that do not supply power over the host cable.
Page 46
3-8
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Digital Imager Scanner Signal Descriptions Bottom of digital imager scanner
Cable interface port
Pin 1
Pin 10
Interface cable modular connector
Figure 3-1 Digital Imager Scanner Cable Pinouts
The signal descriptions in Table 3-3 apply to the connectors on the Symbol DS6707 digital imager scanner and are for reference only. Table 3-3 Symbol DS6707 Digital Imager Scanner Signal Pin-outs
Pin
RS-232/SSI
USB
1
Reserved
Jump to Pin 6
2
Power
Power
3
Ground
Ground
4
TxD
Reserved
5
RxD
D+
6
RTS
Jump to Pin 1
7
CTS
D-
8
Reserved
Reserved
9
Reserved
Reserved
10
Reserved