Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide, pages 171 to 180

Pages 171 to 180 of 416: 123Scan; Symbologies

The original document is the PDF (9.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol DS-3478

Page 171

Chapter 12 123Scan Introduction 123Scan is a Windows®-based utility that programs the digital scanner with all parameters including Advanced Data Formatting (ADF) rules. An ADF rule modifies bar code data before it transmits to the host, ensuring compatibility between bar code data and the host application without having to modify the host software. You can program digital scanners via PC download or by scanning a sheet of bar codes generated by 123Scan. Save digital scanner programming in a file for electronic distribution. 123Scan includes a help file.

Setting Up 123Scan To communicate with the 123Scan program: 1.

Load 123Scan, included in the documentation CD-ROM, onto a host computer running Windows 98, Windows 2000, or Windows XP.

2.

Connect the digital scanner to the host computer using an RS-232 cable. See Connecting an RS-232 Interface on page 7-2.

3.

Scan the following bar code to enable the 123Scan interface on the digital scanner. Refer to the 123Scan instructions for programming the digital scanner.

123Scan Configuration

Page 172

12 - 2 Symbol DS3478 Product Reference Guide

Page 173

Chapter 13 Symbologies Introduction This chapter describes symbology features and provides programming bar codes for selecting these features for the digital scanner. Before programming, follow the instructions in Chapter 1, Getting Started. The digital scanner ships with the settings shown in the Symbology Default Table on page 13-2 (also see Appendix A, Standard Default Parameters for all host and miscellaneous digital scanner defaults). If the default values suit requirements, programming is not necessary. Set feature values by scanning single bar codes or short bar code sequences. To return all features to default values, scan Set Default Parameter on page 4-3. If not using a Synapse or USB cable, select the host type (see the specific host chapter) after the digital scanner emits power-up beeps.

Scanning Sequence Examples In most cases, scan only one bar code to set a parameter value. For example, to transmit bar code data without the UPC-A check digit, scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A/UPC-E/UPC-E1 Check Digit on page 13-14. The digital scanner issues a fast warble beep and the LED turns green, indicating a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes in sequence. See the parameter description for this procedure.

Errors While Scanning Unless otherwise specified, if you make an error during a scanning sequence, re-scan the correct parameter.

Page 174

13 - 2 Symbol DS3478 Product Reference Guide

Symbology Default Parameters Table 13-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in this chapter. NOTE

See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.

Table 13-1 Symbology Default Table

Parameter

Default

Page Number

UPC/EAN UPC-A

Enable

13-7

UPC-E

Enable

13-7

UPC-E1

Disable

13-8

EAN-13

Enable

13-8

EAN-8

Enable

13-9

Bookland EAN

Disable

13-9

Decode UPC/EAN Supplementals (2 and 5 digits)

Ignore Supplementals

13-10

User-Programmable Supplementals

13-13

UPC/EAN Supplemental Redundancy

10

13-13

Transmit UPC-A Check Digit

Enable

13-14

Transmit UPC-E Check Digit

Enable

13-14

Transmit UPC-E1 Check Digit

Enable

13-14

UPC-A Preamble

System Character

13-16

UPC-E Preamble

System Character

13-17

UPC-E1 Preamble

System Character

13-18

Convert UPC-E to A

Disable

13-19

Convert UPC-E1 to A

Disable

13-19

EAN-8 Extend

Disable

13-20

Bookland ISBN Format

ISBN-10

13-21

UCC Coupon Extended Code

Disable

13-22

ISSN EAN

Disable

13-22

Page 175

Symbologies 13 - 3

Table 13-1 Symbology Default Table (Continued)

Parameter

Default

Page Number

Code 128 Code 128

Enable

13-23

Set Length(s) for Code 128

Any Length

13-23

GS1-128 (formerly UCC/EAN-128)

Enable

13-25

ISBT 128

Enable

13-25

ISBT Concatenation

Disable

13-26

Check ISBT Table

Enable

13-27

ISBT Concatenation Redundancy

10

13-27

Code 39

Enable

13-28

Trioptic Code 39

Disable

13-28

Convert Code 39 to Code 32

Disable

13-29

Code 32 Prefix

Disable

13-29

Set Length(s) for Code 39

2 to 55

13-30

Code 39 Check Digit Verification

Disable

13-40

Transmit Code 39 Check Digit

Disable

13-32

Code 39 Full ASCII Conversion

Disable

13-33

Buffer Code 39

Disable

13-34

Code 93

Disable

13-36

Set Lengths for Code 93

4 to 55

13-36

Code 11

Disable

13-38

Set Lengths for Code 11

4 to 55

13-38

Code 11 Check Digit Verification

Disable

13-40

Transmit Code 11 Check Digits

Disable

13-41

Interleaved 2 of 5 (I 2 of 5)

Enable

13-42

Set Lengths for Interleaved 2 of 5

14

13-42

I 2 of 5 Check Digit Verification

Disable

13-44

Code 39

Code 93

Code 11

Interleaved 2 of 5 (I 2 of 5)

Page 176

13 - 4 Symbol DS3478 Product Reference Guide

Table 13-1 Symbology Default Table (Continued)

Parameter

Default

Page Number

Transmit I 2 of 5 Check Digit

Disable

13-44

Convert I 2 of 5 to EAN-13

Disable

13-45

Discrete 2 of 5

Disable

13-46

Set Lengths for D 2 of 5

12

13-46

Codabar

Disable

13-48

Set Lengths for Codabar

5 to 55

13-48

CLSI Editing

Disable

13-50

NOTIS Editing

Disable

13-50

MSI

Disable

13-51

Set Lengths for MSI

4 to 55

13-51

MSI Check Digits

One

13-53

Transmit MSI Check Digit(s)

Disable

13-53

MSI Check Digit Algorithm

Mod 10/Mod 10

13-54

Disable

13-54

Matrix 2 of 5

Disable

13-55

Matrix 2 of 5 Lengths

1 Length - 14

13-56

Matrix 2 of 5 Redundancy

Disable

13-57

Matrix 2 of 5 Check Digit

Disable

13-57

Transmit Matrix 2 of 5 Check Digit

Disable

13-58

Inverse 1D

Regular

13-58

US Postnet

Enable

13-59

US Planet

Enable

13-59

Transmit US Postal Check Digit

Enable

13-60

UK Postal

Enable

13-60

Discrete 2 of 5 (D 2 of 5)

Codabar (NW - 7)

MSI

Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5

Postal Codes

Page 177

Symbologies 13 - 5

Table 13-1 Symbology Default Table (Continued)

Parameter

Default

Page Number

Transmit UK Postal Check Digit

Enable

13-61

Japan Postal

Enable

13-61

Australian Postal

Enable

13-62

Netherlands KIX Code

Enable

13-62

USPS 4CB/One Code/Intelligent Mail

Disable

13-63

UPU FICS Postal

Disable

13-63

GS1 DataBar-14

Enable

13-64

GS1 DataBar Limited

Enable

13-64

GS1 DataBar Expanded

Enable

13-65

Convert GS1 DataBar to UPC/EAN

Disable

13-65

Composite CC-C

Disable

13-66

Composite CC-A/B

Disable

13-66

Composite TLC-39

Disable

13-67

UPC Composite Mode

Always Linked

13-67

GS1-128 Emulation Mode for UCC/EAN Composite Codes

Disable

13-68

PDF417

Enable

13-69

MicroPDF417

Disable

13-69

Code 128 Emulation

Disable

13-70

Data Matrix

Enable

13-71

Data Matrix Inverse

Regular

13-71

Maxicode

Enable

13-72

QR Code

Enable

13-73

QR Inverse

Regular

13-73

MicroQR

Enable

13-74

Aztec

Enable

13-75

Aztec Inverse

Enable

13-75

GS1 DataBar

Composite

2D Symbologies

Page 178

13 - 6 Symbol DS3478 Product Reference Guide

Table 13-1 Symbology Default Table (Continued)

Parameter

Default

Page Number

Symbology - Specific Security Levels Redundancy Level

1

13-76

Security Levels

0

13-78

Intercharacter Gap Size

Normal

13-80

Macro PDF Flush Macro PDF Buffer

13-81

Abort Macro PDF Entry

13-81

Page 179

Symbologies 13 - 7

UPC/EAN Enable/Disable UPC-A To enable or disable UPC-A, scan the appropriate bar code below.

*Enable UPC-A

Disable UPC-A

Enable/Disable UPC-E To enable or disable UPC-E, scan the appropriate bar code below.

*Enable UPC-E

Disable UPC-E

Page 180

13 - 8 Symbol DS3478 Product Reference Guide

Enable/Disable UPC-E1 To enable or disable UPC-E1, scan the appropriate bar code below. NOTE

UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Enable UPC-E1

*Disable UPC-E1 Enable/Disable EAN-13 To enable or disable EAN-13, scan the appropriate bar code below. NOTE

JAN is a subset of EAN, therefore parameters controlling EAN also affect JAN.

*Enable EAN-13

Disable EAN-13