Page 159
Chapter 11 Scanner Emulation Interface Introduction This chapter provides instructions for programming the digital scanner to interface with a scanner emulation host. With scanner emulation, the cradle connects either to an external decoder or to a decoder integrated in a portable terminal or Point-of-Sale (POS) terminal. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*Parameter Process and Pass-Through
Feature/Option
Page 160
11 - 2 Symbol DS3478 Product Reference Guide
Connecting Using Scanner Emulation To perform scanner emulation, connect the digital scanner cradle to a mobile computer, or a controller that collects the data and interprets it for the host.
Interface Cable
Host Port Connector
Figure 11-1 Scanner Emulation Connection NOTE
Interface cables vary depending on configuration. The connectors may be different from those illustrated in Figure 11-1, but the steps to connect the digital scanner cradle are the same. Disconnect the power supply before changing host cables or the digital scanner may not recognize the new host.
1.
Attach the modular connector of the scanner emulation interface cable to the cable interface port on the digital scanner cradle. See Connecting the Cradle on page 1-4.
2.
Connect the other end of the scanner emulation interface cable to the scanner port on the mobile computer or controller.
3.
Ensure all connections are secure.
4.
Pair the digital scanner to the cradle by scanning the bar code on the cradle.
5.
Scan Scanner Emulation Host on page 11-4 to enable the scanner emulation interface.
6.
To modify parameter options, scan the appropriate bar codes in this chapter.
7.
Connect an external power supply if required. CAUTION
Connect the cradle to a 5 volt decoder only. Connecting to a 12 volt decoder can cause damage and invalidate the warranty.
Page 161
Scanner Emulation Interface 11 - 3
Scanner Emulation Default Parameters Table 11-1 lists the defaults for the scanner emulation host. To change an option, scan the appropriate bar code(s) provided in this chapter. NOTE
See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.
Table 11-1 Scanner Emulation Default Table
Parameter
Default
Page Number
Scanner Emulation Host Parameters Beep Style
Beep on Successful Transmit
11-4
Parameter Pass-Through
Parameter Process and Pass Through
11-5
Convert Newer Code Types
Convert Newer Code Types
11-6
Module Width
20 µs Module Width
11-7
Convert All Bar Codes to Code 39
Disable
11-7
Code 39 Full ASCII Conversion
Disable
11-8
Transmission Timeout
3 seconds
11-9
Ignore Unknown Characters
Send Bar Codes with Unknown Characters
11-10
Leading Margin
2 ms
11-11
Check for Decode LED
Check for Decode LED
11-12
Page 162
11 - 4 Symbol DS3478 Product Reference Guide
Scanner Emulation Host Parameters Scanner Emulation Host Scan the following bar code to enable the scanner emulation host.
Scanner Emulation Host
Beep Style The scanner emulation host supports three different beep styles.
• Beep On Successful Transmit (default): The digital scanner beeps when the attached decoder issues the decode signal to the digital scanner. This way, the digital scanner and the decoder beep at the same time.
• Beep at Decode Time: The digital scanner beeps on its decode. This results in a double beep sequence from most decoders, since the digital scanner beeps, and the decoder beeps (at a different frequency) when it successfully decodes the output.
• Do Not Beep: The digital scanner does not beep; the attached decoder issues the decode beep. In all cases, if an error occurs, the digital scanner issues error beeps.
*Beep On Successful Transmit
Beep at Decode Time
Do Not Beep
Page 163
Scanner Emulation Interface 11 - 5
Parameter Pass-Through The scanner emulation host can process parameter bar code messages and send them to the attached decoder. In this way, customers using Symbol-compliant decoders can control the behavior of the system by scanning the necessary parameters only once. NOTE
For example, to enable Discrete 2 of 5, scan the Enable Discrete 2 of 5 parameter bar code with the digital scanner. The digital scanner and the attached decoder both process the parameter.
*Parameter Process and Pass-Through
Parameter Process Only
Page 164
11 - 6 Symbol DS3478 Product Reference Guide
Convert Newer Code Types The digital scanner supports a variety of code types that attached decoder systems typically cannot decode. To allow compatibility in these environments, the digital scanner converts these code types to more common symbologies, as per the following table. Symbologies not listed on this chart transmit normally. Scan this code type:
Transmitted as:
Code 11
Code 39
GS1 DataBar (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF, MaxiCode, Data Matrix, QR Code, Postal Codes, Composite Codes
Code 128
When decoding these code types with this parameter disabled, the digital scanner issues convert error beeps and transmits no data.
*Convert Newer Code Types
Reject Newer Code Types
Page 165
Scanner Emulation Interface 11 - 7
Module Width The standard module width is 20 µs. For an extremely slow decoder system, use this parameter to extend this module width to 50 µs.
*20 µs Module Width
50 µs Module Width
Convert All Bar Codes to Code 39 Scan the appropriate bar code to enable or disable converting all bar code data to Code 39.
*Do Not Convert All To Code 39 (Disable)
Convert All To Code 39 (Enable)
Page 166
11 - 8 Symbol DS3478 Product Reference Guide
Code 39 Full ASCII Conversion By default, this parameter replaces characters that do not have a corresponding character in the Code 39 symbology set with a space. Enable this parameter to encode the data sent to the scanner emulation host in Code 39 Full ASCII. This setting requires that the host be able to interpret Code 39 Full ASCII data. This setting applies only if you enabled Convert All to Code 39.
*Do Not Convert Code 39 To Full ASCII (Disable)
Convert Code 39 To Full ASCII (Enable)
Page 167
Scanner Emulation Interface 11 - 9
Transmission Timeout The scanner emulation host transmits bar code data to the attached decoder and waits for the decoder to assert the decode signal, indicating successful transmission. If, after a specified amount of time, the decode signal is not asserted (indicating that the attached decoder did not receive the bar code data), the digital scanner issues transmit error beeps. Scan the appropriate bar code to select the desired transmission timeout.
*3 Second Transmission Timeout
4 Second Transmission Timeout
5 Second Transmission Timeout
10 Second Transmission Timeout
30 Second Transmission Timeout
Page 168
11 - 10 Symbol DS3478 Product Reference Guide
Ignore Unknown Characters Unknown characters are characters that the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps. Select Do Not Send Bar Codes With Unknown Characters to prevent sending bar codes containing at least one unknown character to the host. The digital scanner issues an error beep.
*Send Bar Codes with Unknown Characters (Enable)
Do Not Send Bar Codes with Unknown Characters (Disable)
Page 169
Scanner Emulation Interface 11 - 11
Leading Margin Scan one of the following bar codes to select a leading margin duration.
1 ms Leading Margin
*2 ms Leading Margin
3 ms Leading Margin
5 ms Leading Margin
10 ms Leading Margin
Page 170
11 - 12 Symbol DS3478 Product Reference Guide
Check for Decode LED The attached decoder typically asserts the decode line to signal to the scanner emulation host that it successfully decoded the transmitted bar code. Some decoders, however, do not assert the decode signal upon a decode. In this case, the digital scanner emits transmit error beeps to indicate that the bar code did not successfully transmit. Scan the Ignore Decode LED bar code to disable the transmit error beeps.
*Check For Decode LED
Ignore Decode LED