Interface Units
Standard Interface Unit Circuit Board FIGURE 3–8. Standard Interface Unit Circuit Board
Controls, Connectors, & Indicators
3
Rev H, February 2002
CiMAX 78xx Technical Reference Manual
3-11
Page 50
Chapter
3
Controls, Connectors, & Indicators
Hex Interface Unit Circuit Board FIGURE 3–9. Hex Interface Unit Circuit Board
3-12
CiMAX 78xx Technical Reference Manual
Rev H, February 2002
Page 51
Interface Units
Programmable Interface Controller Board FIGURE 3–10. Programmable Interface Controller Board
Controls, Connectors, & Indicators
3
Relays in the Interface Units Standard Interface Unit Optional output relay modules can be plugged into locations K1 through K7. Standard Opto-22 style solid state output relay modules with several different AC and DC voltage and power ratings can be provided to fit your application. You can use these relays to operate divert gates, for example. Optional input relay modules can be plugged in to locations K1 through K5. Relay modules with several different AC and DC voltage and power ratings can be provided to fit your application. Position the jumpers associated with relay modules JH1-JH5 to: •
IN when an input relay is used, as shown in Figure 3–11
•
OUT when an output relay is used, as shown in Figure 3–12
•
When no module is used, position the jumper to OUT
FIGURE 3–11. JH1-5 Jumper Setting for Input Relays
Rev H, February 2002
CiMAX 78xx Technical Reference Manual
3-13
Page 52
Chapter
3
Controls, Connectors, & Indicators
FIGURE 3–12. JH1-5 Jumper Setting for Output Relays
K8 is an electro-mechanical relay containing one set of normally open (NO) and normally closed (NC) contacts. You can use K8 to accomplish logic functions with AC line voltage. For example, relays in series can be used to implement the AND logic function. This relay provides contacts that remain open, and contacts that remain closed, when the power is OFF.
Hex Interface Unit JH18 through JH22 are used to isolate inputs 4 through 8 from the three scanners attached to the top three positions (D-F) of the Hex Interface Unit. Normal operation requires that these shunts be installed in the 1-2 position. This will insure that these inputs are connected to all six scanners the same way. If this interface box is used side scanning, then the inputs 4-8 will be connected to proximity sensors that detect which side of the conveyor a box may be positioned. Three scanners will be connected to the lower three positions (A-C) and the scanners on the other side of the conveyor will be connected to the top three positions (D-F). The proximity information should be in reverse order from the lower three scanners. This is accomplished by moving shunts JH18 through JH22 to the 2-3 position. For example, if five proximity sensors are used, install 22 AWG wire between TB1 AND TB11 (IN4-IN8A, IN5-IN7A, IN6-IN6A, IN7-IN5A, IN8-IN4A).
Typical Relay Wiring Examples FIGURE 3–13. Open Collector Output Operating an External Relay
3-14
CiMAX 78xx Technical Reference Manual
Rev H, February 2002
Page 53
Interface Units
FIGURE 3–14. Solid State Output Relay
Controls, Connectors, & Indicators
3
FIGURE 3–15. K-8 Electro-Mechanical Relay Connection
FIGURE 3–16. Solid State Input Relay Module
Rev H, February 2002
CiMAX 78xx Technical Reference Manual
3-15
Page 54
Chapter
3
Controls, Connectors, & Indicators
Interface Unit I/O Connections Table 3–1 shows the Interface Unit I/O Connections at Terminal Block TB1. Default assignments are indicated in parentheses. TABLE 3–1. Interface Unit I/O Connections - TB1
TB1
Signal
In/Out Pwr DB-25
1
Output 1 (NO READ)
9
2
Input 1 (INZONE PRESENCE)
1
3
Output 2 (MATCH)
10
4
Input 2 (OUTZONE PRESENCE)
2
5
Output 3 (NO MATCH)
11
6
Input 3 (TACHOMETER)
3
7
Output 4 (BEEPER)
12
8
Input 4 (HEIGHT SENSOR 1)
4
9
Output 5
13
10
Input 5 (HEIGHT SENSOR 2)
5
11
Output 6
14
12
Input 6 (HEIGHT SENSOR 3)
6
13
Output 7
15
14
Input 7 (HEIGHT SENSOR 4)
7
15
Output 8
16
16
Input 8 (HEIGHT SENSOR 5)
8
18
Beep
12
19
+12 VDC
19
Host DB-9
17
20
Ground
21
+5 VDC
22
Ground
23
Ground
24
+12 VDC
24 5 20
25 26
Host TXD
3
27
Host RXD
2
Host T422+
1
28 29 30 31 32 33 34
3-16
CiMAX 78xx Technical Reference Manual
Rev H, February 2002
Page 55
Interface Units
TABLE 3–1. Interface Unit I/O Connections - TB1 (Continued)
In/Out Pwr DB-25
Host DB-9
TB1
Signal
35
Host T422-
6
36
Host R422+
7
37
Host R422-
9
39
Setup TXD
8
40
Setup RXD
4
41
+5 VDC
25
42
Laser control
17
46
Ground
21
47
Ground
22
48
Ground
23
Frame Ground
18
3
Controls, Connectors, & Indicators
38
43 44 45
49 50
Expansion Board Input Connections Table 3–2 shows the Expansion Board Input Connection at Terminal Block J2. TABLE 3–2. Expansion Board Input Connections
J2 Marked
Assignment
1 (INZ)
Height Input 1
2 (ANG)
Height Input 2
3 (TACH)
Height Input 3
4 (HT1)
Height Input 4
5 (HT2)
Height Input 5
6 (HT3)
Height Input 6
7 (HT4)
Height Input 7
8 (HT5)
Inzone Presence (connect to TB1-2)
9 +5V
+5V
10 GND
GND
11 CTSOUT
CTSOUT (RS-232)
12 CTSIN
CTSIN (TTL)
Photoeye & Tachometer Connections Connections shown here are for SICK Auto Ident, Inc. parts only.
Rev H, February 2002
CiMAX 78xx Technical Reference Manual
3-17
Page 56
Chapter
3
Controls, Connectors, & Indicators
Use TB3, TB4 and TB5 instead of TB1 for complete opto-isolation. Refer to Table 3–1, “Interface Unit I/O Connections - TB1,” on page 3-16 for TB1 assignments. FIGURE 3–17. Photoeye & Tachometer Connections
Brown
935-0018-1
Black Blue White (not used)
Brown
935-0018-1
Black Blue White (not used)
Brown
Black Blue White (not used)
Gray/White 950-0003-1
Brown/White Green/White
Connectors on Scanner I/O Connector Panel Refer to Table 3–1, Table 3–2, and Table 3–3 for connector and signal specification for the Scanner I/O connector. TABLE 3–3. I/O Connections
3-18
Pin
Host
Set/Star
1
Host T422+
LAN+ (blue wire)
2
Host RXD
TERM DETECT
3
Host TXD
LAN- (white wire)
4
Host DTR
Ground
5
Ground
Frame Ground (cable shield)
CiMAX 78xx Technical Reference Manual
Rev H, February 2002
Page 57
Interface Units
TABLE 3–3. I/O Connections (Continued)
Pin
Host
Set/Star
6
Host T422-
Ground
7
Host R422+
TERM RXD
8
Host CTS
TERM TXD
9
Host R422-
+5 VDC, 500 mA max
3
Controls, Connectors, & Indicators
I/O Connector Panel FIGURE 3–18. I/O Connector Panel
I N / O U T P W R
25
13
9 6
14
5
1
S E T / S T A R
1 6 9
1
5
H O S T
Optional Ethernet connector
Host Connector Host Connections are also available on TB1 in the Standard and Hex Interface Unit and are brought to the scanner through the I/O Connections connector. The Host Connector provides an asynchronous serial I/O port that can be used to connect to a host computer or to other serial, ASCII
Rev H, February 2002
CiMAX 78xx Technical Reference Manual
3-19
Page 58
Chapter
3
Controls, Connectors, & Indicators devices (such as printer, display terminals, external keyboards, etc.). Control of data flow, baud rates, etc., are determined by parameters you can set. Refer to the Scanner Parameters Reference Guide for more information. This port can use RS-232, RS-422 or full modem protocols. Pins 2, 3, and 5 are always used for RS-232 communication. Pins 1, 5, 6, 7, and 9 are used for RS422 communication. Your host may require using other pins or making other connections in order to send and receive data. The Host Connector contains two asynchronous serial I/O communication ports, Host and Terminal. The Host Port is used to connect the 78xx Scanner to a host computer or controller to transfer barcode data for processing. The SETUP Port is used to connect the scanner to another scanner or to a printer, display terminal or computer. Control of data flow, baud rates, communications protocols, etc., from both ports can be set by means of parameters and software jumpers (parameters 100-199, 200-299, and 495). Refer to the Scanner Parameters Reference Guide for more information. The Host port can be programmed to use either RS-232 or RS-422 conventions, or both. The SETUP port uses only RS-232.
Set/Star Connector The Starnode Connector allows the 78xx Scanner to be connected to an EIA-485 Starnode local area network (LAN). This network connection is not implemented in the Interface Unit. You must attach your network cable directly to the connector on the front panel of the scanner. Refer to Table 3–3, “I/O Connections,” on page 3-18.
Setup Port Functionality on Starnode Connector The SETUP connector is provided as an input port for a local terminal. You can connect a CiMAX 1400 hand-held terminal, an ASCII terminal or a PC running a terminal emulation program. This port uses RS-232 conventions and runs at 9600 baud. Refer to Table 3–3, “I/O Connections,” on page 3-18. Setup connections are also available on TB1 in the Standard and Hex Interface Units and are connected to the scanner through the I/O Connections connector. A terminal can be used to display and change parameters values and run diagnostic tests. These functions are described in other chapters in this manual. Most terminals only require connection to pins 6, 7 and 8. The CiMAX 1400 terminal also uses pins 2 and 9. A cable with the necessary connections is provided with the terminal. Some terminals may require connecting to or jumpering other pins.
Ethernet Connectors (Optional) A BNC coaxial connector (standard) for 10 Base 2 thinnet or an RJ-45 connector for 10 base T twisted pair is provided with an Ethernet option. No Ethernet connections are available in the Standard or Hex Interface Units. If your scanner has the Ethernet option installed, you must attach your network cable directly to the RJ-45 connector on the I/O Connector panel of the scanner.
3-20
CiMAX 78xx Technical Reference Manual
Rev H, February 2002