The text of a manual · part 8 of 14
AD TOUCH TRACKER 16 System Operator's Manual: Chapter 4: Defining Automatic System Functions, pages 52 to 60
Pages 52 to 60 of 108, from AD TOUCH TRACKER 16 System Operator's Manual
The original document is the PDF (568 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sensormatic TouchTracker 16
Page 52
Defining the Sequence Tip: You must use the Main TOUCH TRACKER to define the Sequence.
The following procedure describes how to define the Sequence. 1. Press the Menu button on the keypad. The TOUCH TRACKER is now in the menu/programming mode, and the menu appears: Calibration Define Sequence
2. Press the appropriate button - zoom or focus - to select Define Sequence. If the Sequence has not been defined, or if the first event in the Sequence was not defined, the LCD looks like this: Evt Cam Act Dur 01 -- View- --
If someone has already set up the Sequence, and the first event has been defined, the information for the first event in the Sequence appears on the LCD. For example: Evt Cam Act Dur 01 7 View25 10
3. Use the Tracker Ball to scroll to the event you want to define. 4. In the Cam field, indicate the camera on which this event was defined, or the camera whose fixed shot you want to include. Use the number buttons to enter the camera number.
4-10
Operator's Manual
Page 53
5. In the Act field, indicate the type of Action (Quick View, Pattern, or fixed shot) you are specifying for this event. Press View to indicate a Quick View or a fixed shot; press Pattern to indicate a Pattern. 6. Use the number buttons on the keypad to designate the specific number of this Quick View or Pattern. This number was assigned to the Quick View or Pattern when it was initially defined. If you want the Action to be a fixed shot, press the Clear button. 7. In the Dur field, use the number buttons to enter the duration time, in seconds, for this event. The maximum duration time is 90 seconds. The duration time must be entered as two digits. For example, enter “05” for 5 seconds. 8. Use the Tracker Ball to scroll to the next event, and repeat Steps 4 through 7 for each event you want to include in this Sequence. You can define up to 16 events. You can leave any event undefined by pressing the Clear button when the cursor is in the Cam field for that event. 9. When you complete defining the Sequence, press the Menu button. This returns the TOUCH TRACKER to the camera control mode.
Tip: A shortcut method for defining the Sequence is available. Press Menu, then Seq to start sequence programming. Use the Tracker Ball to scroll to the appropriate event number. Follow steps 4–9 above to assign the camera, action, and duration to each event in the sequence.
Setting Up System Alarms You can define up to 64 different alarms that can be triggered by the inputs connected to domes at your facility. An alarm is triggered when one of these inputs changes from its normal state to its abnormal state. For example, if the input is a smoke detector, its normal state would be “not detecting smoke.” However, when the smoke detector detects smoke, it changes to its abnormal
Defining Automatic System Functions
4-11
Page 54
state, and this triggers an alarm. (Refer to your List of Inputs and Outputs in Appendix A to determine the normal and abnormal state for each input.) When an alarm is triggered, it can automatically call up one video action (either a Quick View, a Pattern, or a fixed shot) and initiate one output. This video action must have been defined for the same dome that the output is connected to, and vice versa. Refer to your List of Inputs and Outputs in Appendix A to determine which outputs are connected to which domes. Refer to your List of Quick Views and List of Patterns in Appendix A to determine which Quick Views and Patterns were defined for which domes. It might be helpful for you to fill out the Setup Alarms Worksheet in Appendix A before you begin setting up an alarm. On the Setup Alarms Worksheet you can calculate which inputs on which domes will trigger which video action and output, if any. You can then refer to this worksheet when you are actually setting up an alarm.
Tip: You must use the Main TOUCH TRACKER to set up Alarms.
The following procedure describes how to set up a system alarm. 1. Using the number buttons, enter the number of the camera for which you are setting up the alarm. Then press the Camera button. 2. Press the Menu button. The TOUCH TRACKER is now in the menu/programming mode, and the menu appears: Calibration Define Sequence
3. Use the Tracker Ball to scroll through the menu selections until Alarm Actions is displayed on the LCD. Record Pattern Alarm Actions
4-12
Operator's Manual
Page 55
4. Press the appropriate button - zoom or focus - to select Alarm Actions. The information for that camera's first alarm input appears on the LCD. When you set up an alarm, you will indicate which Quick View, Pattern, or fixed shot will be called up when the alarm is triggered. You will also indicate which output initiates when this alarm is triggered. The video action and the output must be associated with the same dome. A sample setup alarm LCD is shown here. Cam12/1 => Cam7 View96 Out3
If an alarm input has not been set up yet, the fields will have dashes in them. A setup alarm LCD contains the following information: 1
2 This is the dome and input that will trigger an alarm when a change in state is detected.
This is the dome whose video appears on the monitor when the alarm occurs.
Cam12/1 => Cam7 View96 Out3 4 3 This is the specific Quick View or Pattern that appears when the alarm is triggered. If there is no number in this field, this indicates a fixed shot.
This is the specific output that initiates when the alarm is triggered.
In this sample alarm, input 1 on camera 12 is the specific input that will trigger the alarm. The alarm input, for example, could be a motion detector that triggers an alarm when it senses motion. When this alarm is triggered, Quick View 96 on camera 7 appears on the monitor. In addition, output 3 on the same camera initiates automatically. The output might be, for example, a light that turns on when the alarm is triggered.
Defining Automatic System Functions
4-13
Page 56
Even though you can only see the information for one alarm input at a time, each camera can have four alarm inputs. When the TOUCH TRACKER is in the menu/programming mode, the Tracker Ball enables you to move the cursor around on the LCD. The blinking square on the LCD indicates the cursor's location. Move the Tracker Ball left and right to move the cursor among the fields on the LCD. 5. When the setup alarm LCD is first displayed, the cursor is in the Cam field for input 1 of the camera you indicated. Is this the alarm input that you want to configure? If so, continue with Step 6 now. If this is not the alarm input you want to configure, use the Tracker Ball to scroll through the available inputs until the appropriate input appears in the input field. 6. In the Cam field, indicate the camera whose Quick View, Pattern, or fixed shot appears when this alarm is triggered. This is the same camera whose output initiates when the alarm is triggered. Use the number buttons on the keypad to enter the camera number. 7. Move the Tracker Ball to the right move the cursor to the next field. 8. Choose one of the following:
4-14
•
Do you want a Quick View to be displayed when this alarm is triggered? If so, use the number buttons to indicate the specific Quick View (1 - 96).
•
Do you want a Pattern to be displayed when this alarm is triggered? If so, press the Pattern button, and then use the number buttons to indicate the specific Pattern (1 - 3).
•
Do you want a fixed shot to be displayed when this alarm is triggered? If so, press the View button, but do not enter any number in this field. When this alarm is triggered, you will see
Operator's Manual
Page 57
video of wherever the camera (that you indicated in Step 6) is currently pointing. 9. Move the Tracker Ball to the right. In the Out field, indicate the specific output that initiates when this alarm is triggered. Use the number buttons to enter the number. Remember, this output must be connected to the camera you assigned in Step 6. If you do not want an output to be initiated, leave this field blank. 10. Choose one of the following: •
Do you want to set up another alarm input for this camera? If so, use the Tracker Ball to scroll through the available inputs until the appropriate input appears in the input field. Then repeat Steps 6 through 9.
•
Do you want to set up an alarm for another camera? If so, press the Next button on the keypad until the appropriate camera number appears in the Alarm Cam field. Then, repeat Steps 5 through 9.
•
Are you finished setting up alarms for now? If so, press the Menu button. This returns the TOUCH TRACKER to the camera control mode.
SpeedDome LT Auto Pan Programming The Auto Pan is a special feature supported by SpeedDome LT only. It allows you program a smooth side-to-side camera pan of an area. The SpeedDome LT does not allow you to program the same types of Patterns that other domes support. Instead, use Pattern programming to set the Auto Pan function.
Auto Pan Programming Limitations Keep the following limitations in mind when programming the SpeedDome LT Auto Pan feature:
Defining Automatic System Functions
4-15
Page 58
•
Although it appears to have three Patterns available to program, you can only program the Auto Pan feature for Pattern 1.
•
Any extraneous movements made during the Auto Pan programming will be ignored when the programming is complete. Once the end point of the Auto Pan is set, the result will be a smooth pan between the start point and the end point of the Auto Pan.
•
Do not attempt to create an Auto Pan that is greater than one revolution (360º) of the SpeedDome LT. The dome will accept this pattern during programming; however, it will not work when you attempt to run the pattern. The starting point and the ending point must be less than one revolution of the SpeedDome for the Auto Pan to work properly.
•
If you attempt to program Pattern 2 or 3 as different Auto Pans for the dome, the system will take you through the motions of the programming. However, the new Auto Pan will not be saved. Do not attempt to program more than one Auto Pan per SpeedDome LT.
•
If you need to re-program the Auto Pan for the dome, you must select the Pattern 1. Selecting another available Pattern number will not change the previously programmed Auto Pan.
To program the Auto Pan for SpeedDome LT, do the following:
Tip: You must use the Main TOUCH TRACKER to define the Auto Pan for SpeedDome LT.
1. Using the number buttons, enter the number of the SpeedDome LT for which you are defining the Auto Pan (for example, camera 3). Then press the Camera button. 2. Pan and tilt the camera to the starting point of the Pattern, and then zoom and focus the camera accordingly.
4-16
Operator's Manual
Page 59
3. When you have the perfect “starting point” picture displayed on the monitor, press the Menu button. The TOUCH TRACKER is now in the menu/programming mode, and the menu appears: Calibration Define Sequence
4. Use the Tracker Ball to scroll through the menu selections until Record Pattern is displayed. Record Pattern Alarm Actions
5. Press the appropriate button - zoom or focus - to select Record Pattern. The following prompt appears on the LCD: Cam 3 Enter Patrn#?
IMPORTANT The Auto Pan must be programmed for Pattern 1 only.
6. Press the number 1 on the keypad. The following message appears on the LCD: Record Pattern 1 Finish w <Next>
7. The Auto Pan is now being recorded. Any extraneous up or down movement will be ignored when programming the Auto Pan.
Defining Automatic System Functions
4-17
Page 60
If you pressed an invalid number (any number greater than 3), the TOUCH TRACKER will beep and the system will not allow you to program the Pattern. If this happens, simply press a valid number and continue with this procedure. 8. Move the camera until you see end point for the Auto Pan you are programming. Keep in mind this end point must be less than one full revolution of the dome. 9. When you see the end point, press the Next button. The following message appears on the LCD: Cam 3 Pattern Saved
The TOUCH TRACKER automatically returns to the camera control mode. In the List of Patterns (in Appendix A of this manual), make a record of the Auto Pan that you just defined, including a brief description of the Auto Pan. To test the Auto Pan that was programmed, press 1, then Pattern. The Auto Pan will run continuously until a camera command, such as tilt or focus, is issued.
4-18
Operator's Manual