Page 61

C H A P T E R

5

A B

Peel Info

C

1 Me nu

2

Ou tputOn

D 3

4

Off Clea r

Flip

5 6

Vi ew

7 Clos

Patte rn

8 e Iris

9

Op en

Cam era

Repea P atte t rn

0 Dis pla

Seq y

P rev Next

TOUCH TRACKER Utilities In This Chapter • • • • • • • • •

Calibrating the Tracker Ball Resetting the Dome Selecting a Language Designating Main Versus Call TOUCH TRACKER Toggling the Zoom and Focus Buttons Toggling Automatic/Manual Alarm Acknowledgment Displaying a Dome's ID Code Adjusting Camera V-Phase Special Utilities

Page 62

Calibrating the Tracker Ball Calibration “tunes” the Tracker Ball sensors for maximum range of motion and balance. If you need to calibrate the Tracker Ball, the following procedure describes how to do this. At any time during this procedure you can press Clear to exit the calibration process; however, no calibration values are saved unless the entire calibration sequence is completed. If you exit prematurely, the TOUCH TRACKER will retain the previously set calibration values. 1. Press the Menu button on the keypad to display the menu. 2. Scroll through the menu and press the appropriate button - zoom or focus - to select Calibration. The LCD displays the following prompt: Calibration Push Ball Left

3. Immediately push the Tracker Ball all the way to the left until the LCD displays this prompt: Calibration Push Ball Right

4. Immediately push the Tracker Ball all the way to the right until the LCD displays this prompt: Calibration Push Ball Down

5. Immediately push the Tracker Ball all the towards you until the LCD displays this prompt: Calibration Push Ball Up

5-2

Operator’s Manual

Page 63

6. Immediately push the Tracker Ball all the way away from you until the LCD displays this prompt: Calibration Release Ball

7. Remove your finger from the Tracker Ball. The LCD displays this prompt: Calibration Calibration Done

8. Press the Menu button to exit the menu/programming mode. The TOUCH TRACKER is now re-calibrated and it automatically returns to the camera control mode.

Resetting the Dome If you find that one of the SpeedDome Series of cameras is not responding as expected to TOUCH TRACKER commands, you should reset the dome. The following procedure describes how to reset the dome. 1. Using the number buttons, enter the number of the camera you want to reset (for example, camera 5) and then press the Camera button. 2. Press the Menu button to display the menu. 3. Use the Tracker Ball to scroll through the menu items and press the appropriate button - zoom or focus - to select Reset Dome. The LCD displays the following message: Cam 5 Reset In Process

The SpeedDome is inoperable while it is resetting. Once the SpeedDome is reset, the TOUCH TRACKER returns to the camera control mode.

TOUCH TRACKER Utilities

5-3

Page 64

Selecting a Language Choose which language you would like the TOUCH TRACKER LCD text appear in: • • • •

English French Spanish German

• • • •

Dutch Italian Japanese Portuguese

• •

Swedish Hungarian

1. Press the Menu button on the keypad to display the menu. 2. Use the Tracker Ball to scroll through the menu items and press the appropriate button - zoom or focus - to choose Select Language. The LCD displays the list from which you can choose a language. English Francais

The list only displays two choices at any one time. 3. Use the Tracker Ball to scroll through the language selections, and press the appropriate button - zoom or focus - to select the correct language. The TOUCH TRACKER resets and comes back up in the selected language. The TOUCH TRACKER is again in the camera control mode.

Designating Main Versus Call TOUCH TRACKER If your facility has two TOUCH TRACKERs installed, one was installed as the Main TOUCH TRACKER and the other as the Call TOUCH TRACKER. You cannot designate both TOUCH TRACKERs as Main or Call; this will cause a communication error. The chart on the following page outlines which features are available to the Main TOUCH TRACKER, and the limited feature set of the Call TOUCH TRACKER.

5-4

Operator’s Manual

Page 65

TOUCH TRACKER Functions

Main TOUCH TRACKER

Designate which external unit the system is connected to (quad splitter, multiplexer, PC, no unit)

!

Select display mode (2x2, 3x3, 4x4, or full-screen format

!

Select a camera

! ! ! !

Manually control a camera (pan, tilt, zoom, focus, iris) Flip a SpeedDome Initiate automatic system functions (Quick Views, Patterns, outputs) Run the Sequence

!

Clear alarms

!

Define automatic system functions (Quick Views, Patterns, Sequence, alarms)

!

Calibrate the Tracker Ball

! ! ! ! !

Reset a SpeedDome Select language for TOUCH TRACKER text Designate Main vs. Call TOUCH TRACKER Toggle zoom and focus buttons

Call TOUCH TRACKER

! ! ! !

! ! ! ! !

As your needs change, you may want to switch the Main and Call TOUCH TRACKERs.

TOUCH TRACKER Utilities

5-5

Page 66

IMPORTANT The following procedure describes how to toggle the current Main and Call TOUCH TRACKERs. Before you begin this procedure, you must know which TOUCH TRACKER you want to designate the Main, and which one you want as the Call. You can distinguish between the two TOUCH TRACKERs by looking at their menus. The Main TOUCH TRACKER contains all of the menu items, while the Call TOUCH TRACKER has a limited menu selection. If you want to toggle the functionality of the TOUCH TRACKERs, first you must do so on the current the Main TOUCH TRACKER.

1. On the Main TOUCH TRACKER, press the Menu button to display the menu. 2. Scroll through the menu items and press the appropriate button - zoom or focus - to select Tog Primary/2nd. The LCD displays the following prompt: Primary Unit Change w <Next>

3. Press the Next button to designate this the Call TOUCH TRACKER. 4. Press the Menu button to exit the menu/programming mode on this TOUCH TRACKER. 5. On the other TOUCH TRACKER, press the Menu button to display the menu. 6. Scroll through the menu items and then press the appropriate button - zoom or focus - to select Tog Primary/2nd.

5-6

Operator’s Manual

Page 67

The LCD displays the following prompt: Secondary Unit Change w <Next>

7. Press the Next button to designate this the Main TOUCH TRACKER. 8. Press the Menu button to exit the menu/programming mode on this TOUCH TRACKER. The TOUCH TRACKER resets and comes back up in the camera control mode.

Toggling the Zoom and Focus Buttons The function of the zoom and focus buttons can be configured according to the preference of each individual user. If you do not have a preference as to key arrangement and you do not configure the keys, the Zoom button will be on the left side and the Focus button will be on the right side of the Tracker Ball. This configuration is illustrated here: Zoom

Focus

If you are right-handed you may prefer to use your index finger to control the focus button; therefore, you would want to “swap” the focus button to the left side of the Tracker Ball. If you are left handed you may want to use your index finger to control the focus button. Therefore, you would want to “swap” the focus button to the right side of the Tracker Ball, as shown above.

TOUCH TRACKER Utilities

5-7

Page 68

The following procedure describes how to toggle the zoom and focus buttons. 1. Press the Menu button on the TOUCH TRACKER whose buttons you want to toggle. 2. Scroll through the menu items and then press the appropriate button - zoom or focus - to select Tog Zoom/Focus. The LCD displays the current arrangement of the zoom and focus buttons, for example: Zoom on Left Focus on Right

3. Press the Next button to switch the buttons' functionality. The LCD then displays the new arrangement of the zoom and focus buttons, for example: Zoom on Right Focus on Left

4. Press the Menu button to exit the menu/programming mode. The TOUCH TRACKER is again in the camera control mode.

5-8

Operator’s Manual

Page 69

Toggling Automatic/Manual Alarm Acknowledgment The default setting for the TOUCH TRACKER is to automatically clear alarms after 60 seconds. You can, however, change this to have alarms manually acknowledged by the system operators. To toggle the Automatic/Manual Alarm Acknowledgment function, do the following: 1. Press the D button. If Automatic Alarm Acknowledgment is enabled, you will see the following: Auto Ack Alarm

If Manual Alarm Acknowledgment is enabled, you will see the following: Manual Ack Alarm

2. Press D again to change alarm acknowledgment to the preferred type. 3. Press the Clear button to return the LCD to camera control mode.

TOUCH TRACKER Utilities

5-9

Page 70

Displaying a Dome's ID Code The following procedure describes how to display the ID code for the currently selected dome. The ID code may be useful when diagnosing a problem. 1. Using the number buttons, enter the number of the dome whose ID code you want to display (for example, camera 3) and then press the Camera button. 2. Press the Info button on the keypad. The LCD displays the following prompt: Cam 3 F 0701-0081-0134

Notice the “F” prefix in front of the ID code; this indicates that it applies to the dome's Flash PROM. 3. Press the Info button again to display the dome's EEPROM ID code. Cam 3 E 0701-0079-0310

Notice the “E” prefix in front of the ID code; this indicates that it applies to the dome's EEPROM. 4. Each time you press the Info button, you alternate between the Flash PROM and the EEPROM ID codes. 5. Press the Clear button to refresh the LCD. The TOUCH TRACKER is again in the camera control mode.

5-10

Operator’s Manual

Page 71

Adjusting Camera V-Phase Use of this utility should be limited to authorized service personnel. To adjust the V-phase of a selected camera, do the following: 1. Press Menu. 2. Using the Tracker Ball, scroll down to Adjust V-Phase. 3. Press the Zoom or Focus button to select the Adjust V-Phase menu option. 4. Press Next or Previous to observe the V-Phase through the oscilloscope or Fluke scope. 5. Press Menu to exit.

IMPORTANT Off-line domes or fixed cameras will generate a warning beep and disallow use of the V-Phase utility. For additional information on adjusting the VPhase, see the service section of the AD Touch Tracker 16 manual.

Special Utilities Although Show Sys Info and Ping Dome/TTR are considered utility items on the menu, these utilities are reserved for use by authorized service personnel. However, you may also perform these tasks in conjunction with an authorized service provider over the phone. There are no procedures in this documentation describing their use.

TOUCH TRACKER Utilities

5-11