Page 43

C H A P T E R

4

A B

Peel Info

C

1 Me nu

2

Ou tputOn

D 3

4

Off Clea r

Flip

5 6

Vi ew

7 Clos

Patte rn

8 e Iris

9

Op en

Cam era

Repea P atte t rn

0 Dis pla

Seq y

P rev Next

Defining Automatic System Functions In This Chapter • • • • • •

Defining a Quick View Defining a Pattern Understanding Sequence Programming Defining the Sequence Setting Up System Alarms SpeedDome LT Auto Pan Programming

Page 44

Defining a Quick View IMPORTANT The SpeedDome Ultra III and newer domes support up to 96 views. Older programmable domes support up to 4 views. The TOUCH TRACKER beeps when you attempt to program a view numbered higher than 4 on domes older than the SpeedDome Ultra III.

A Quick View automatically and instantaneously calls up a view from a programmable dome, regardless of where that dome is currently pointing. You can define your own Quick Views to support your specific needs. Depending on the type of dome, either 4 or 96 views may be defined.

Tip: You must use the Main TOUCH TRACKER to define Quick Views.

If you make a mistake during programming or you no longer want to program the Quick View, press the Menu or the Clear button at any time to cancel programming. The TOUCH TRACKER returns to the camera control mode.

The following procedure describes how to define a Quick View. 1. Using the number buttons, enter the number of the programmable camera for which you are defining this Quick View (for example, camera 7). Then press the Camera button. 2. Pan and tilt the camera so that it is pointing at the view you want to define. Then zoom and focus the camera accordingly. 3. When you have the perfect picture displayed on the monitor, press the Menu button.

4-2

Operator's Manual

Page 45

The TOUCH TRACKER is now in the menu/programming mode, and the menu appears: Calibration Define Sequence

4. Use the Tracker Ball to scroll through the menu selections until Setup View is displayed on the LCD. Setup View Record Pattern

5. Press the appropriate button, zoom or focus, to select Setup View. The following prompt appears on the LCD: Cam 7 Enter View#?

Note

If you press a number that has already been assigned to a Quick View for this camera, the new Quick View will overwrite the existing Quick View. There is no warning to indicate that the existing Quick View will be replaced. Use caution.

6. Press the number on the keypad (1 - 96) that you want to assign to this Quick View, then press Zoom or Focus. The following message appears briefly on the LCD: Cam 7 View Saved

If you press an invalid number (any number greater than 96), the TOUCH TRACKER beeps, and the system will not save the Quick View. If this happens, simply press a valid number and the Quick View will be saved. The TOUCH TRACKER automatically returns to the camera control mode.

Defining Automatic System Functions

4-3

Page 46

In the List of Quick Views (found in Appendix A of this manual), make a record of the Quick View you just defined, including a brief description of what the Quick View is “looking at.”

Tip: A short cut method for defining Quick Views is available. Press Menu, View, the Quick View number, and Zoom or Focus to create a Quick View of the current scene.

Defining a Pattern You can define your own Patterns to support your specific needs. You can program up to three Patterns per programmable dome. The length and complexity of a Pattern are restricted by two variables: • •

Number of camera commands Time

Each time you move the camera in any direction, zoom in or out, focus near or far, or adjust the iris, you have issued camera commands to the camera. The three Patterns for a dome can collectively consist of up to 98 camera commands. As you program a Pattern, the number of camera commands remaining for that camera appears on the TOUCH TRACKER LCD. There is also a time constraint on Patterns. A single Pattern cannot have a duration longer than approximately 6 minutes and 50 seconds. Even if a Pattern has only two camera commands in it, the Pattern will stop recording once its duration time has elapsed. Patterns are programmed in real-time. This means that the camera is remembering every programming command you make at the actual speed you issue the commands. For example, if you let the camera sit still for 20 seconds during programming, that is exactly what the camera will do each time that Pattern is called up in the future. The 20 seconds of “non-motion time” is part of the Pattern.

4-4

Operator's Manual

Page 47

Tip: You must use the Main TOUCH TRACKER to define Patterns.

The SpeedDome LT does not support Pattern programming. Refer to the section in this chapter titled “SpeedDome LT Auto Pan Programming” for information about setting the Auto Pan feature.

The following procedure describes how to define a Pattern. 1. Using the number buttons, enter the number of the programmable camera for which you are defining the Pattern (for example, camera 3). Then press the Camera button. 2. Pan and tilt the camera to the starting point of the Pattern, and then zoom and focus the camera accordingly. 3. When you have the perfect “starting point” picture displayed on the monitor, press the Menu button. The TOUCH TRACKER is now in the menu/programming mode, and the menu appears: Calibration Define Sequence

Defining Automatic System Functions

4-5

Page 48

4. Use the Tracker Ball to scroll through the menu selections until Record Pattern is displayed. Record Pattern Alarm Actions

5. Press the appropriate button - zoom or focus - to select Record Pattern. The following prompt appears on the LCD: Cam 3 Enter Patrn#?

Note

If you press a number that has already been assigned to a Pattern for this camera, the new Pattern will overwrite the existing Pattern. There is no warning to indicate that the existing Pattern will be replaced. Use caution.

6. Press the number on the keypad (1 - 3) that you want to assign to this Pattern, for example 1. The following message appears on the LCD: Record Pattern 1 Finish w <Next>

7. The Pattern is now being recorded in real-time. If you let the camera sit still at this point, that non-motion time will be recorded in the Pattern. If you pressed an invalid number (any number greater than 3), the TOUCH TRACKER will beep and the system will not allow you to program the Pattern. If this happens, simply press a valid number and continue with this procedure. 8. Move the camera around and create a logical, usable Pattern. Remember, the three Patterns for this camera can collectively incorporate up to 98 camera commands, and each Pattern can be up to 6 minutes and 50

4-6

Operator's Manual

Page 49

seconds long. The number of commands remaining for this camera appears on the LCD as you program the Pattern. 9. When you complete programming the Pattern, press the Next button. The following message appears on the LCD: Cam 3 Pattern Saved

The TOUCH TRACKER automatically returns to the camera control mode. In the List of Patterns (in Appendix A of this manual), make a record of the Pattern you just defined, including a brief description of the Pattern.

Tip: A shortcut method is available for defining Patterns. Press Menu, Pattern, and the Pattern number. Move the camera in the desired pattern, then press Next when finished.

Understanding Sequence Programming You can define a Sequence that incorporates up to 16 events. An event is a Quick View or Pattern that you have already defined; an event can also be a fixed shot. The events that you include in the Sequence can be defined for any camera. For each event, you designate a duration time, which indicates how long that event will remain on the monitor before the Sequence switches to the next event. Before you begin defining the Sequence, you should have a clear understanding what you want to include in the Sequence. Refer to the lists that you compiled (in Appendix A) of the available Quick Views and Patterns. Make sure you can answer the following questions: •

Which Quick Views, Patterns, and fixed shots will you include in the Sequence?

Defining Automatic System Functions

4-7

Page 50

•

What are the numbers that were assigned to those Quick Views and Patterns when they were defined?

•

What are the camera numbers that the Quick Views and Patterns were defined on? What are the camera numbers whose fixed shots you want to include?

It is recommended that you to fill out the Setup Sequence Worksheet in Appendix A before you begin setting up the Sequence. On the Setup Sequence Worksheet you can list all of the events - along with their numbers, the cameras on which they were defined, and their duration times - to be included in the Sequence. You can then refer to this worksheet when you are actually setting up the Sequence.

Sequence Programming Display Before you begin programming the Sequence, you should have a basic understanding of the fields shown during Sequence programming. The following illustration provides an overview of the fields: Column 1

Column 2

Column 3

Column 4

Evt Cam Act Dur 01 5 View96 10 02 7 Patn3 05 03 -- View- -. .

16

12 View- 30

Events in a Sequence are divided into four columns: column 1 column 2 column 3

4-8

“Evt” is the number of the event (1 through 16) within the Sequence; this number determines which event comes first, second, third, etc. “Cam” is the camera number on which the event was defined. “Act” is the type of event (Quick View, Pattern, or fixed shot), and number assigned to that event when it was originally defined (1 through 96 for Views; 1 through 3 for Patterns; blank for fixed shots).

Operator's Manual

Page 51

column 4

“Dur” is the amount of time, in seconds, that the event will remain on the monitor before the Sequence switches to the next event. This is the event's duration time. The maximum duration time is 90 seconds.

When the fields in an event have dashes in them instead of values, the event is not defined. Leaving an event undefined instructs the Sequence to skip that event. When the TOUCH TRACKER is in the menu/programming mode, the Tracker Ball enables you to move the cursor around on the LCD. The blinking square on the LCD indicates the cursor's location. Move the Tracker Ball up and down to move the cursor from event to event. Move the Tracker Ball left and right to move the cursor among the fields within an event. When the define Sequence LCD is first displayed, the cursor is in the Cam field. This is where you indicate on which camera the first event to be included in the Sequence was defined. If the Sequence has not been defined, or if the first event in the Sequence was not defined, the LCD looks like this: Evt Cam Act Dur 01 -- View- --

If someone has already set up the Sequence, and the first event has been defined, the information for the first event in the Sequence appears on the LCD. For example: Evt Cam Act Dur 01 7 View2 10

In the sample Sequence LCD (above), the first event is Quick View 2, defined on camera 7, and its duration time is 10 seconds.

Defining Automatic System Functions