Page 21

Operator’s Guide

Inspector D4000™ Laser

The next selection is Scans/Analysis:

Scans/Analysis Single From this screen you may choose the number of scans (from 1 (single) to 10 or continuous) to be used in the analysis. When set to continuous the D4000 will scan and grade bar codes until the Laser trigger is released, then the Continuous Results screen will be displayed: (See 8.5 Continuous Mode) The last selection is Comparison Mode:

Comparison Mode Off When Comparison Mode is On, the first bar code scanned after turning Comparison Mode On will be saved as the Master bar code. All bar codes scanned will be compared to the Master bar code and if the encoded data does not match then a No Match error will be displayed. (See 7.2, Comparison Mode) Note: When all Setup selections have been made, the RJS Inspector D4000 will navigate back to the Main Menu automatically. All setup parameters are retained in non-volatile memory and will be saved until changed by you - even if the power is turned off.

002-7858

15

RJS, Minneapolis, MN

Page 22

Operator’s Guide

Inspector D4000™ Laser

5.3 Storage Storage will display as either Storage Inactive or Storage % depending on whether Store and Print is enabled or disabled. When Store and Print is enabled, a number and a percentage sign 00% to 99% will display. When Store and Print is disabled, Storage Inactive will display.

Scan Setup Storage Inactive D4000L Ver.x.xx “Inactive” displays when Store and Print is inactive.

Scan Setup Storage XX% D4000L Ver.x.xx A storage “%” displays when Store and Print is active. If a % is displayed, it represents the percentage of the buffer that is filled with scan data. You may enable or disable Store and Print by pressing Enter with the cursor on Storage. (Toggle from one option to the other) When Storage is active, press Select to move the cursor to the % sign. Press Enter on the % sign to clear the Store and Print buffer. (See Appendix H, Print Functions)

002-7858

16

RJS, Minneapolis, MN

Page 23

Operator’s Guide

Inspector D4000™ Laser

6.0 Scanning Symbols 6.1 Scanning Techniques Lay the symbol to be scanned on a flat, nonreflective surface While the laser beam is not over a bar code pull the trigger on the Laser Adjust the angle and distance of the Laser to the bar code sample so that the distance results in a laser beam that is twice as wide as the bar code (at least 2 inches wide) and the angle is at 30 degrees (angle of the exit window on the Laser) Once at the proper angle and distance, drag the laser beam over the bar code (maintaining the angle and distance)

(See Appendix A - Scanning Technique) 6.2 Scanning Results After a bar code is scanned, the RJS Inspector D4000 will respond with a crisp, chirp (or beep) sound. Inspector Display after a scan when the Multiple Scan analysis is set to two:

*1234ABCD* 01 Scans Remain.

002-7858

17

RJS, Minneapolis, MN

Page 24

Operator’s Guide

Inspector D4000™ Laser

Press Select to view the grade for the previous scan (applies when there are one or more scans remaining):

*1234ABCD* Code 3of9 D/bility % .64 D/bility Grade A Note: See 7.0 Pass/Fail Analysis Screen section for details the inspection tests and results

002-7858

18

RJS, Minneapolis, MN

Page 25

Operator’s Guide

Inspector D4000™ Laser

7.0 Pass/Fail Analysis Screen After the symbol is scanned the Pass/Fail Analysis Screen will be displayed. An example of a Pass/Fail Analysis Screen for an acceptable symbol is shown below:

*1234ABCD* Code 3of9 D/bility % .64 D/bility Grade A This screen shows: The first line is the decoded data. (If more than 16 characters are present, those characters will wrap to the next row of the display) Press Select to scroll through the data The second line provides the Symbology type The third line is the ISO/ANSI Decodability percentage grade The fourth line is the ISO/ANSI Decodability letter grade Below is a sample of scans remaining in multiple scan mode if the last scan has not been completed.

*1234ABCD* 02 Scans Remain. If the symbology code is 128, only printable characters will be displayed. Note: See Appendix E for descriptions of how these codes are displayed

002-7858

19

RJS, Minneapolis, MN

Page 26

Operator’s Guide

Inspector D4000™ Laser

Table 7-A (Code Identifier Descriptions for Pass/Fail Analysis Screen) Identifier Symbology Type B-1 B345 LOG HIBC 3 OF 9 39+C 25+C I25 CC GS1 C128 UPCA UA+2 UA+5 UPCE UE+2 UE+5 EAN8 E8+2 E8+5 EN13 13+2 13+5

Code 39; B-1 sub-specification for AIAG Code 39; B3, 4, 5, or 10 sub-specification for AIAG Code 39; LOGMARS sub-specification Code 39; HIBC sub-specification Code 39; Traditional ISO/ANSI sub-specification Code 39; with Mod 43 Interleaved 2 of 5 with Mod 10 Interleaved 2 of 5 Interleaved 2 of 5 ITF-14 sub-specification GS1-128 Code 128 Code 128 UPC version A UPC version A plus 2 digit addendum UPC version A plus 5 digit addendum UPC version E UPC version E plus 2 digit addendum UPC version E plus 5 digit addendum EAN 8 character EAN 8 plus 2 digit addendum EAN 8 plus 5 digit addendum EAN 13 character EAN 13 plus 2 digit addendum EAN 13 plus 5 digit addendum

Note: The Identifiers listed above are displayed when the bar code is acceptable. Some Identifiers will be different if a warning is issued for the bar code.

002-7858

20

RJS, Minneapolis, MN

Page 27

Operator’s Guide

Inspector D4000™ Laser

Table 7-B (Code Identifiers RJS Inspector D4000) LOGMARS AIAG B-1 AIAG B 3/4/5/10 Code 3 of 9 HIBC 3 of 9 3of9 W/43 I 2 of 5 w/mod10 Std I2of5 ITF14 Case Code GS1-128 Std 128 X - Y % UPC-A X - Y % UPCA+2 X - Y % UPCA+5 X - Y % UPC-E X - Y % UPCE+2 X - Y % UPCE+5 X - Y % EAN-13 X - Y % EAN13+2 X - Y % EAN13+5 X - Y % EAN-8 X - Y % EAN8+2 X - Y % EAN8+5

Code 39 symbology Code 39 symbology Code 39 symbology Code 39 symbology Code 39 symbology Code 39 symbology Interleaved 2 of 5 symbology Interleaved 2 of 5 symbology Interleaved 2 of 5 symbology Code 128 symbology Code 128 symbology

Uniform Product Code, Ver. A Uniform Product Code, Ver. A with 2 digit Add Uniform Product Code, Ver. A with 5 digit Add Uniform Product Code, Ver. E Uniform Product Code, Ver. E with 2 digit Add Uniform Product Code, Ver. E with 5 digit Add European Article Number 13 digit European Article Number 13 digit with 2 digit Add European Article Number 13 digit with 5 digit Add European Article Number 8 digit European Article Number 8 digit with 2 digit Add European Article Number 8 digit with 5 digit Add

Note: On the previous tables, all ISO/ANSI symbologies use the traditional specifications for bar width deviation. X and Y represent the magnification range selected for UPC/EAN tolerances.

002-7858

21

RJS, Minneapolis, MN

Page 28

Operator’s Guide

Inspector D4000™ Laser

7.1 Multi-scan mode When multi-scans are selected, the number of remaining scans needed to complete the analysis are displayed:

*0192837465* 03 Scans Remain The resulting analysis is an average of the scans. Press the Select to view the Results screen:

*1234ABCD* Code 3of9 D/bility % .64 D/bility Grade A After the last scan a double beep or chirp will signal completion of the scan. 7.2 Comparison Mode The first bar code scanned after turning Comparison Mode On will be saved as the “Master” bar code. All bar codes scanned will be compared to the “Master” bar code and if the encoded data does not match then the following screen will be displayed.

No Match Note: To enter a new “Master” bar code, toggle the Comparison Mode selection to Off and then to On again.

002-7858

22

RJS, Minneapolis, MN

Page 29

Operator’s Guide

Inspector D4000™ Laser

8.0 Data Analysis Screens After doing a scan, the Pass/Fail Analysis screen is displayed press Enter to bring up the Data Analysis Screens. (See Pass/Fail Analysis, 7.0) 8.1 Encoded Data The first screen to display is the Decoded Symbol Data from the Pass/Fail Screen:

*1234ABCD* Note: If more than 16 characters are present, those characters will wrap to the next row of the display Note: Code 128 is an exception. See Appendix E for details

002-7858

23

RJS, Minneapolis, MN

Page 30

Operator’s Guide

Inspector D4000™ Laser

8.2 Modulo Check Character Press Select to bring up the next screen (if applicable):

Modck: 9 Expect:9

PASS

This display indicates (when applicable) the Modulo check character decoded and the Modulo check character that should have been decoded (expected) in the symbol. PASS or FAIL is also indicated. Note: For Code 128, the mod check character (Mod 103) is displayed as the symbology’s character value (a number from 000 to 102). One or two numeric Mod check characters may precede the 3-digit Code 128 Mod check described above. These digits represent the Mod 10 check character(s) that can be included depending on the format.

8.3 Symbol Specific Errors Press Select to bring up the next screen:

90-115% UPC-A Acceptable Symbology type is indicated on the top row and the analysis overview on the bottom row.

002-7858

24

RJS, Minneapolis, MN