Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 8

Inspector D4000 Laser Operator's Guide, pages 11 to 20

Pages 11 to 20 of 75

The original document is the PDF (352 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the RJS Inspector D4000

Page 11

Operator’s Guide

Inspector D4000™ Laser

2.0 Warranty 2.1 General Warranty Warranty information: +1 (763) 746-8034 RJS warrants your RJS Inspector D4000 to be free from defects in material and workmanship for a period of 1 year from the date of shipment from RJS’ factory location. The liability of RJS under this warranty is limited to repairing or replacing the defective part and/or unit. RJS may optionally choose to issue credit for any unit returned during the warranty period. You must promptly notify RJS of any defect in order to receive the full protection of this warranty. 2.2 Warranty Limitations The warranty set forth above is exclusive and no other warranty, whether written or oral is expressed or implied. RJS specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. However, any implied warranty of merchantability or fitness is limited to the one year duration of this written warranty. RJS shall in no event be liable for any indirect, incidental, or consequential damages, including but not limited to damages which may arise from loss of anticipated profits or production delivery delays, spoilage of material, increased costs of operation of business or otherwise.

002-7858

5

RJS, Minneapolis, MN

Page 12

Operator’s Guide

Inspector D4000™ Laser

2.3 Service during the Warranty Period If your RJS Inspector D4000 should fail during the warranty period, contact RJS or its authorized representative immediately upon discovery of the defect. A Return Authorization Number (RMA number) may be obtained by visiting our website address: http://www.rjs1.com/request_rma.php You will be asked to ship the product in its original packing, freight prepaid, with the RMA number visibly written on the outside of the carton to RJS’ factory location. Be sure to include any samples or printouts or other information that will help us to understand the problem. Your repair will be given priority treatment, or your unit may be replaced at RJS’ option. The repaired item will be returned UPS/United States Postal Service ground, freight prepaid. At your request we will ship express or overnight if you need premium service and agree to pay the additional cost.

002-7858

6

RJS, Minneapolis, MN

Page 13

Operator’s Guide

Inspector D4000™ Laser

3.0 Introduction 3.1 Warnings Do not point the Laser in the direction of the eyes so that the light beam emitted by the unit strikes the eyes directlythis could result in eye damage. Keep the unit and gun away from a water source such as a faucetthis could short the unit and cause injury. Users of the verifier (unit and gun) are not authorized to open case(s) or in any way modify circuitry. The following caution labels should already be on the Laser (and must remain on the Laser): LASER LIGHT - DO NOT STARE INTO BEAM EMITTED WAVELENGTH 630-680nm MAX. OUTPUT RADIATION 1.0mW CLASS 2 LASER PRODUCT EN 60825-1:2007

If a caution label(s) with equivalent information as shown on the examples to the right are not on the Laser, notify RJS at once.

This product complies with 21 CFR Subchapter J CLASS 2 LASER LIGHT WHEN OPEN AVOID EXPOSURE - LASER LIGHT IS EMITTED FROM THIS APERTURE DO NOT STARE INTO BEAM

This equipment complies with the requirements in part 15 of FCC rules for a class A computing device. Operation of this equipment in a residential area may cause interference in radio and TV reception, requiring the operator to take whatever steps are necessary to correct the interference. Class II laser product. This product conforms to DHMS regulation 21 CFR subchapter J for use with listed class II EDP equipment

!

Not user serviceable. Opening case voids warranty.

002-7858

7

RJS, Minneapolis, MN

Page 14

Operator’s Guide

Inspector D4000™ Laser

3.2 RJS Inspector D4000 Description and Features The RJS Inspector D4000 is an advanced technology bar code verifier that makes it easy to decode bar code symbols and to evaluate symbol compliance with industry standards. Features Automatic power-on by pressing trigger Scan bar codes on curved surfaces GS1-128 data content validation Auto-discriminates between many different symbologies Auto-print mode Low battery indicator Barcode symbol data and deviation displays Multiple scan averaging Power-down is automatic after short period of disuse Programmable, multi-scan analysis Store and print capabilities Visual and audible signals Note: The D4000 Laser is NOT a full ISO/ANSI bar code verifier. It will ONLY inspect the Decodability parameter (which will be accurate when the Laser is held at the proper angle and distance). If you need to comply with the ISO15416 bar code quality standards then the D4000 Auto Optic will be required.

002-7858

8

RJS, Minneapolis, MN

Page 15

Operator’s Guide

Inspector D4000™ Laser

3.3 Maintenance To ensure the best possible scanning conditions, keep the laser window and display window clean. Use a soft, damp, lint-free cloth to clean the windows. Do not use solvents on the unit or on any of the components. You may use alcohol to clean the unit.

3.3 Temperature Specs Do not operate or store your unit or components in temperatures outside the range of 50° - 105°. Do not operate or store your unit in conditions of high humidityover 80%.

002-7858

9

RJS, Minneapolis, MN

Page 16

Operator’s Guide

Inspector D4000™ Laser

4.0 The RJS Inspector D4000 Laser Serial interface Battery Charger

LCD Window

5 Indicator LED’s Function Buttons Laser Scanner

Stand

Battery Cover

002-7858

10

RJS, Minneapolis, MN

Page 17

Operator’s Guide

Inspector D4000™ Laser

5.0 Main Menu Selections 5.1 Power On When the unit is powered on, the following “Ready” screen will display after a few seconds:

D4000L Ver x.xx Ready x.xx = Current revision of the firmware Press Enter and Select at the same time to bring up the Main Menu:

Scan Setup Storage Inactive D4000L Ver.x.xx x.xx = Current revision of the firmware The selectable functions are: Scan, Setup and Storage:

Press Select to choose an option. Press Enter to initiate processing for that option.

Select Scan (from the Main Menu) to display the initial Pass/Fail Analysis screen for the previously scanned bar code.

5.2 Setup Select Setup (from the Main Menu) to view various system parameters: Press Select to choose an option Press Enter to initiate processing for that option The first selection is Decodability Warning: 002-7858

11

RJS, Minneapolis, MN

Page 18

Operator’s Guide

Inspector D4000™ Laser

D/bility Warning D Select an ISO/ANSI Decodability grade to use in your analysis. (See Appendix C for an explanation of the grades) A warning message will be produced for the selected grade or any lower grades: B C D F NONE If NONE is selected, the Decodability grade will not be used to trigger a warning message. However, the Decodability grade will be calculated and available for viewing. The next selection is UPC/EAN tolerance:

UPC/EAN Tol. 116 - 150% Mag. The magnifications are: 80 - 89 % Mag 90 - 115 % Mag 116 - 150 % Mag 151 - 200 % Mag (See Appendix G for an explanation of magnifications)

002-7858

12

RJS, Minneapolis, MN

Page 19

Operator’s Guide

Inspector D4000™ Laser

The next selection allows you to select if the check digit for UPC/EAN Random Weight bar codes should be tested:

UPC/EAN Rnd. Wt. Off Note: Select On to activate UPC/EAN random weight check digit calculations. (See Appendix B, Table B-2

Notes) The next selection is Decode 3 of 9 as:

Decode 3of9 as Code 3of9 This selection is for choosing the Code 39 sub-specifications for analysis: Code 3 of 9 3of9 w/43 AIAG B-1 AIAG B-3/4/5/10 LOGMARS HIBC 3 of 9 The next selection is Decode I 2 of 5 as:

Decode I2of5 as Std I2of5 This selection is for choosing the Code I 2 of 5 sub-specifications for analysis: Std I2of5 ITF14 Case Code I25 w/mod 10 002-7858

13

RJS, Minneapolis, MN

Page 20

Operator’s Guide

Inspector D4000™ Laser

The next selection is Decode C128 as:

Decode C128 as Std 128 This selection is for choosing the Code 128 subspecifications for analysis: Std 128 GS1-128 (tests all Application IDs and code length) The next selection is Auto Print Mode:

Auto Print Mode Off Two choices are available in Auto Print Mode: 1. On: (For the TP140A / TP140 / TP40 / Computer) Both ISO/ANSI and Traditional analysis will print automatically after a symbol is scanned. 2. Off: You must press the print button to print. (See Appendix H - Print Functions) The next selection is Output Device:

Output Device TP140 Three output choices are available: 1. When TP140 is enabled, the data is output in the format required by a TP140/TP140A printer 2. When TP40 is enabled, data output is in the format of analysis only 3. When Computer is enabled, data is output in computer readable format (text and graphics) (See Section 9.0, Connect to Computer) 002-7858

14

RJS, Minneapolis, MN