The text of a manual · part 4 of 8
Inspector D4000 Laser Operator's Guide, pages 31 to 40
Pages 31 to 40 of 75
The original document is the PDF (352 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RJS Inspector D4000
Page 31
Operator’s Guide
Inspector D4000™ Laser
8.4 Inspection Results Press Select to bring up the next screen:
Ratio: 2.2 P D/bility .48 C -100% Tol. +100% --------RRARR+++ This screen shows: The first line is the Ratio calculation (when applicable) The second line is the ISO/ANSI Decodability percentage and letter grade The third line and fourth lines are the Bar width deviations chart “R” letters represent “range” of bar widths in the code. “A” represents the average of all character bar width deviations. Note: The location of the “A” is indicated with the 5 LEDs also See Table 8-A.
The closer the “A” is to the center of the display, the better. The following shows the percentage of the scanning tolerance used at each position on the display: 93
79
Negative numbers to the left indicate bars that are narrower Positive numbers to the right indicate bars that are wider
002-7858
65
50
36
22
8
1
0
25
+ 8
+ 22
+ 36
+ 50
+ 65
+ 79
RJS, Minneapolis, MN
+ 93
Page 32
Operator’s Guide
Inspector D4000™ Laser
The closer the “A” is to the edge, the more likely the Reject. A symbol is “Acceptable” until any calculated bar width deviation exceeds 100% of the tolerance for the symbology decoded; for example: Bar Width - Acceptable
-100% Tol. +100% ------RRARR+++++ Bar Width - Warning
-100% Tol. +100% --------++RRRARR Bar Width - Rejected
-100% Tol. +100% --------+++++++R “A” is out of tolerance and off the screen. Note: Could also be on negative side (See Table 8-A for visual display of deviations)
002-7858
26
RJS, Minneapolis, MN
Page 33
Operator’s Guide
Inspector D4000™ Laser
Table 8-A (LED, Bar code Width Deviations) 5 LED Display Average Bar width deviation as a Pattern % of tolerance Within +21% to -21% Within +22 to +49% Within +50 to +78% Within +79 to +99% Out of tolerance (wide) Within -22 to -49% Within -50 to -78% Within -79 to -99% Out of tolerance (narrow) Note: Solid indicators represent LEDs turned on and the 9 possible patterns are displayed.
002-7858
27
RJS, Minneapolis, MN
Page 34
Operator’s Guide
Inspector D4000™ Laser
8.5 Continuous Mode In the Continuous Mode, an additional data analysis screen displays:
Continuous Mode #Decodes 013/019 %Decodes 68%
13 good decodes out of 19 attempted reads Percentage of good reads
The first line indicates the results are for a scan captured with the Continuous Mode On The second line is the number of scans with decoded bar codes and the number of scan attempts. The third line is the percentage of bar codes decoded to scan attempts. (This is NOT the ISO/ANSI Decodability percentage)
There is a limit of 100 good scans in the Continuous Mode (or 250 total scans) whichever comes first. When a limit is reached, the unit automatically stops scanning. Note: In Continuous Mode the unit continues to attempt reads as long as the Laser trigger is depressed. When using this mode the beam may be moved around the symbol to provide extra analysis. The analysis result is based on the average. Note: After scanning a bar code, the Inspector D4000 will return to the last Data Analysis screen displayed before the bar code was scanned. The Data Analysis screens will cycle through a loop. Once the last screen has been viewed, pressing the Select button again will return the Inspector D4000 to the initial Data Analysis Screen.
002-7858
28
RJS, Minneapolis, MN
Page 35
Operator’s Guide
002-7858
Inspector D4000™ Laser
29
RJS, Minneapolis, MN
Page 36
Operator’s Guide
Inspector D4000™ Laser
9.0 Connect to other Devices Connect to Computer You may store and print the analysis on a Windows PC computer using the optional VCIR software package. (Your RJS Inspector D4000 Laser will connect to a computer with a serial interface cable; 9600 BPS, 8 bit, no parity, 1 stop bit) Connect to Printer Your RJS Inspector D4000 will connect to an RJS TP140A/TP140/TP40 printer with a serial interface cable. Contact RJS to order either the VCIR software or printer: RJS Technologies 701 Decatur Ave North, Suite 107 Minneapolis, MN 55427 +1 (763) 746-8034 Sales@rjs1.com
002-7858
30
RJS, Minneapolis, MN
Page 37
Operator’s Guide
Appendix A
Appendix A (Scanning Technique) The D4000 Laser bar code verifier utilizes the CR2 Laser which has three major improvements when compared to the previous models: Codes with an X dimensions as small as 5 mils (0.005 inch, 0.127 mm) can be analyzed (vs. 0.0075 inch, 0.190 mm). More accurate correlation to the ISO/ANSI Decodability calculation is achieved. Scanning Technique Lay the symbol to be scanned on a flat, nonreflective surface While the laser beam is not over a bar code pull the trigger on the Laser Adjust the angle and distance of the Laser to the bar code sample so that the distance results in a laser beam that is twice as wide as the bar code (at least 2 inches wide) and the angle is at 30 degrees (angle of the exit window on the Laser) Once at the proper angle and distance, drag the laser beam over the bar code (maintaining the angle and distance) Figure A-1 (Scanning Position)
Note: A label containing this information is also attached to the top of the scanner for quick reference.
002-7858
31
RJS, Minneapolis, MN
Page 38
Operator’s Guide
Appendix A
Special Considerations When scanning codes on a low contrast substrate like corrugated material or a specular substrate (such as shiny aluminum or plastic material), a scan angle other than 30 degrees may produce better decoding characteristics. Contact RJS Technical support if scanning problems occur.
002-7858
32
RJS, Minneapolis, MN
Page 39
Operator’s Guide
Appendix B
Appendix B (Symbology Analysis) Symbology Analysis Parameters Table B-1 shows error messages that will be displayed for each parameter type checked by the RJS Inspector D4000. Table B-1 (Parameter/Error Message)
Parameter
Data Analysis Message
Ratio Ratio 1.8 < or > 3.4 Inter-Character Gap (ICG) Invalid Data Character Too Few Characters I 2 of 5 Case code not 14 or 18 characters Code 128 GS1 Case code not 14 or 18 characters or not all numeric characters Mod Check Digits PCS Bar Width Deviation Edge of Range (Wide) Bar Width Deviation Edge of Range (Narrow) Bar Width Deviation Out of Range (Wide) Bar Width Deviation Out of Range (Narrow) Addendum Parity (UPC/EAN) ISO/ANSI Decodability (if enabled) Object in Quiet Zone Quiet Zone Too Small <Fnc1> with Standard C128 No <Fnc1> with GS1 Selected
Warning Ratio Rejected Ratio Bad ICG Invalid format Invalid format Invalid format
002-7858
33
Invalid format
Bad Mod. Check Rejected PCS Warning Wide Warning Narrow Rejected Wide Rejected Narrow Invalid Format Warn D/bility (DCD, in initial Pass/Fail screen) Defects F, 50% or greater Warning QZ/SS Format Warning Warn Missing F1
RJS, Minneapolis, MN
Page 40
Operator’s Guide
Appendix B
Table B-2 (Parameters Checked for Each Symbology) Symbology
Ratio
ICG
AIAG B-1
2.2-3.2
.5X-8X
AIAG B-3 B-4 B-5 B-10
2.8-3.2
.5X-8X
LOGMARS
2.2-3.0
.5X-8X
CODE 3 OF 9
2.2-3.0
.5X-8X
3 OF 9 W/43
2.2-3.0
.5X-8X
HIBC 3 OF 9
2.2-3.0
.5X-8X
INTERLVD 2 OF 5
2.2-3.0
N/A
CASE CODE
2.3-2.9
N/A
CODE 128
N/A
N/A
CASE CODE 128
N/A
N/A
UPC/EAN
N/A
N/A
CODABAR VARIANT CODE 93
2.2-3.0
.5X-8X
N/A
N/A
Data Character STD CODE 39 $/+% Not Allowed
Mod Check N/A
Tolerance
N/A
STD CODE 39 STD CODE 39 STD CODE 39 4 CHARS Min STD CODE 39 Min 2 CHARS 1ST. = "+" N/A
N/A
((12R8)/81)X ((12R8)/81)X ((12R8)/81)X ((12R8)/81)X
3 Data Chars Min. N/A
MOD 10
16 Data Char. Format Check N/A STD CODABAR STD CODE 93
N/A MOD 43
((12R8)/81)X
MOD 43
((12R8)/81)X
N/A
((18R1)/80)X ((18R1)/80)X .35X
MOD 103 Mod 10 Mod 102
MOD 10
.35X
N/A
See Note 1 (below) ((5R-8)/20)X
C&K
.35X
Notes:
X = X dimension
R = Ratio in the calculations
Tolerance is expressed as a fraction of the X dimension
See Appendix D for Quiet Zone Analysis descriptions. Note:
UPC/EAN tolerances: 80 - 89% = .14X 90 - 115% = .30X 116 - 150% = .34X
002-7858
34
RJS, Minneapolis, MN