Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 24 of 41

7035/8255/8260 Terminals User Manual: Setting Parameters 7, pages 205 to 214

Pages 205 to 214 of 348, from 7035/8255/8260 Terminals User Manual

The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix 7942, Teklogix 7978, Teklogix 7035, Psion 7942 and Psion 7978

Page 205

Chapter 7: Setting Parameters Serial 1 And Console 2 Parameter Settings Serial 1 and Console 2 sub-menus change depending on the device you choose. Ports Serial 1 Parameters Console 2 Parameters Enable Speed Data Bits Parity Stop Bits Flow Ctrl Buffer Retries Retry Tmo Input Tmo Scan-See Test

9600 8 None 1 None 512 3 50 2 » N

Enable » Disable » Range 1200 2400 4800 9600 7-8 None Odd Even 1-2 None XON/XOFF 32-2048 1-100 0-100 0-100 see page 181

Y/N

Speed This parameter determines the bit rate of the port.

Data Bits This parameter determines the number of bits for the data going through this port.

Parity This parameter determines the type of parity checking used on the data going through the port. The options are Odd, Even and None.

Stop Bits This parameter specifies the number of stop bits – 1 or 2 – used for asynchronous communication.

Teklogix 7035, 8255 & 8260 Terminals User Manual

179

Page 206

Chapter 7: Setting Parameters Serial 1 And Console 2 Parameter Settings

Flow Control This parameter selects the type of flow control used in your terminal. The 7035 can perform XON/XOFF and/or CTS/RTS handshaking. Keep in mind that CTS/RTS hardware flow control generally results in faster data throughput. Note: Flow Control under ‘Serial 1’ contains the following options: None, CTS/RTS, XON/XOFF and Both. Options available under ‘Console 2’ include: None and XON/XOFF. The function of each mode is as follows: Enable: Used to input and output data. Supports XON/XOFF and/or CTS/RTS or no handshaking. Print: Used to output data only. All input characters except XON and XOFF are ignored. Supports XON/XOFF and/or CTS/RTS or no handshaking. Output: Used to output data only. All input characters are ignored. Supports CTS/RTS or no handshaking. Note: To enable the input and/or output, ‘serial in’ and/or ‘serial out’ must be enabled in the TESS menu.

Buffer The value assigned to this parameter determines the size of the serial buffer used by the application for both input and output. The buffer controls how much data the application can send to or receive from a serial device.

Retries Note: “Retries” is not available if “Nomad” or “Scan-See” is chosen as the peripheral device. This parameter determines the number of times the terminal attempts to transmit a byte from the serial port. If the count specified in this parameter is exceeded, the transmission fails. Keep in mind that the value assigned to this parameter must be exceeded before data in the buffer is thrown away. To disable this parameter and force the terminal to use “Retry Tmo”, this parameter should be set to ‘1’.

180 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 207

Chapter 7: Setting Parameters Serial 1 And Console 2 Parameter Settings

Retry Tmo Note: “Retries” is not available if “Scan-See” is chosen as the peripheral device. This parameter sets the time in seconds that the terminal waits before transmissions stop and data from the transmit buffer is discarded. Keep in mind that the value assigned to this parameter must be exceeded before data in the buffer is thrown away. A value of ‘0’ (zero) disables this parameter.

Input Tmo Note: “Retries” is not available if “Scan-See” is chosen as the peripheral device. This parameter sets the time in tenths of a second that the terminal waits before passing received data to the TESS or ANSI tasks.

Scan-See – Setting The Terminal Console Port For proper communication between a Scan-See and a Teklogix terminal, the console port of the terminal must be properly configured. The parameters for setting up the console port are located in the “Ports” setup menu, under “Console 2” in the “Parameters” sub-menu: Ports Serial 1 Disable Parameters » Console 2 Scan-See Parameters » The “Console 2” parameters (described on page 178) should be set as follows: Scan-See Speed 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None Buffer 512 Scan-See » Test N

Teklogix 7035, 8255 & 8260 Terminals User Manual

181

Page 208

Chapter 7: Setting Parameters Global Macros

Note: In order for the terminal to interface to Scan-See units with older firmware (serial numbers lower than 1594120224), set “Parity=space”; all other parameters are identical to the newer firmware. For details about the Scan-See sub-menu parameters, refer to the “Scan-See & Wireless Scan-See Scanner User Manual – PN 80408”.

Nomad – Setting The Terminal Console Port For Nomad To interface the terminal to the Nomad scanner, “Console 2” must be configured for NOMAD. For detailed information about configuring the Nomad scanner, refer to the “LS3070™ Wireless Scanner User Manual” – PN 80416.

Test This parameter sends a block of ASCII data out the serial port. This function is used during configuration only and has no effect on the emulation.

7.11 Global Macros A macro has 19 programmable characters (or “positions”). The macro keys can be programmed to replace frequently used keystrokes, along with the function of executable keys like <ENTER>, <DEL>, function keys and arrow keys. They may also be used to provide characters not normally accessed from the keyboard. The methods used to create macros are described in this section.

7.11.1 Displaying The Global Macros Menu Macros are programmed from within the “Global Macros” menu. If the Tekterm application is currently active: •

Press <ALT> and type x to exit the Tekterm application.

The “Display Menu” appears on the terminal screen. 01 Display Menu A Parameters B Emulations C DOS Prompt

182 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 209

Chapter 7: Setting Parameters Displaying The Global Macros Table To display the “Parameters” menu: • Type the letter a. • Type your password in the Password window, and press <ENTER>. Parameters System Scanner Applications View Manager GPS Ports Global Macros Network SNMP Radio Sound ANSI FK Remap

» » » » » » » » » » »

7.11.2 Displaying The Global Macros Table To display the “Global Macros” table: • In the “Parameters” menu, position the cursor on the “Global Macros” option, and press <F1> to display the macro table. Note: This is a sample 44-key 7035 macro table. Vehicle-mount terminals displays 12 macro fields rather than 4. Global Macros #1 #2 #3 #4 •

Position the cursor in the macro field corresponding to the macro key to which you want to assign macros – #1 corresponds to macro key <M1>, #2 corresponds to macro key <M2>, and so on.

Once the cursor is in a macro field, you have a number of options when creating a macro. You can type text and numbers, choose from a set of ASCII characters and program the function of special keys into a macro.

Teklogix 7035, 8255 & 8260 Terminals User Manual

183

Page 210

Chapter 7: Setting Parameters Choosing An ASCII Character In macros, the <UP> arrow, <DOWN> arrow, <ENTER> and <DEL> keys have the following functions: • Pressing the <UP> and <DOWN> arrow keys move the cursor between entry fields. • Pressing the <ENTER> key once moves the cursor to the first position in the entry field; pressing <ENTER> a second time completes the entry field, exits the sub-menu and returns the cursor to the “parent” or previous menu. • The <DEL> key deletes the character to the left of the cursor. • The <CLR> key – <BLUE> <DEL> – clears the entire field. If the last character in a field is deleted, the previous contents, if any, reappear.

7.11.3 Choosing An ASCII Character Important:

Make sure the <CTRL> and <SHIFT> keys are turned off!

By pressing either the <RIGHT> or <LEFT> arrow key, you can cycle through a set of printable characters not available on the keyboard. The sample below is a set of ASCII characters not accessible from the keyboard. 7035: / < > % ^ & ` ~ | [ ] { } " ' ? = + ; 8255/8260: ^ & ‘ ~ | [ ] { } ’ " •

Press the <RIGHT> arrow to display the next character in this sequence, and the <LEFT> arrow to display the previous one.

7.11.4 Adding Additional ASCII Characters When you’ve chosen an ASCII character and want to add another one in the same field, the cursor must be moved to the right of the existing character. Normally, pressing the <RIGHT> arrow key moves the cursor to the right, but in a string entry field, pressing the <RIGHT> arrow key cycles through the available ASCII characters instead. If you’ve already chosen an ASCII character and want to add another one in the field, you need to take a few extra steps to move the cursor to the right. To add another ASCII character in the string entry field, next to the one you’ve already chosen: • Type a numeric character – for example, type the number 7. • Next, press the <DEL> key. The cursor is now positioned to the right of the previously selected ASCII character. • Press the <RIGHT> or <LEFT> arrow key to scroll through the ASCII characters, and select another character. 184 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 211

Chapter 7: Setting Parameters Programming Special Keys Into Macros

7.11.5 Programming Special Keys Into Macros Macros can contain the function of a subset of terminal keys. The keys that can be programmed into macros include: <ENTER>, <DEL> and <CLR> (<BLUE><DEL>), function keys and arrow keys. To program the function of a key: • With the cursor in the “Global Macros” table, use the arrow keys to position the cursor in the macro field corresponding to the macro key you want to program – the field labelled #1 represents <M1>, and so on. • Press <CTRL> and then, type the letter l (el) (l represents “literal”). • Press the key you wish to add to the macro. For example: To execute the function of the <ENTER> key in a macro, type <CTRL> l <ENTER>.

7.12 Network Note: This menu is not displayed if the “802.IQ” protocol is set to “Y” in the “Radio” sub-menu or if a narrow band radio is installed in the terminal.. Range Network Local IP see text Net Mask see text Default Gateway see text Use DHCP N» see text Use DNS N» see text Ether Packet Sz 1500 1500 512 1024 1490 Mobile IP N» see text 802.IQ v2 » see text

Local IP This parameter is used to assign a unique terminal IP address so that the terminal can be identified on the network. The format is ###.###.###.###

Net Mask A subnet mask is assigned at this parameter. The 7035 uses the subnet mask, it’s own IP address and the destination IP address to determine if a packet should be sent on the local network or a remote subnet. If the destination is found to reside on the local network, the packet is sent directly to its destination. If the destination resides on a remote subnet, the packet is routed to the appropriate gateway. The accepted values for “Net Mask” range from 0.0.0.0 to 255.255.255.255. Note: The terminal “Net Mask” must match the network controller net mask. Teklogix 7035, 8255 & 8260 Terminals User Manual

185

Page 212

Chapter 7: Setting Parameters Network

Default Gateway The “Default Gateway” IP address assigned at this parameter creates an identifiable communication link between the terminal and a remote sub-network – that is, a network other than the one in which the terminal is currently operating. The acceptable values for this parameter range from 0.0.0.0 to 255.255.255.255. Note: Setting the “Default Gateway” to 0.0.0.0 disables this feature. A communication link will not exist between sub-networks.

Use DHCP Range

Use DHCP Network Info

DCHP

Local

When “Use DHCP” is set to ‘Y’, the IP address and subnet mask are always taken from the DHCP server. The sub-menu attached to this parameter offers two options – DHCP or Local. If ‘Network Info’ is set to DHCP, the DNS server (IP), the DNS suffix (Domain) and the default gateway will also come from the DHCP server. If ‘Network Info’ is set to Local, these values will be taken from the locally configured (terminal) values. Note: If “Use DHCP” is set to “Y”, the “IP Address” parameter (see page 185) should be left blank.

Use DNS Use DNS DNS IP DNS Domain

Range see text see text

Setting “Use DNS” (Domain Name System) to ‘Y’ allows access to your DNS server. The options in the sub-menu – DNS IP and DNS Domain – allow you to specify the IP address and domain name of your DNS server. The DNS domain is appended to any host name that does not include a suffix. For example, if your applications menu includes the server name Jack, and the DNS Domain is teklogix.com, the DNS server is queried for the IP address of Jack.teklogix.com.

186 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 213

Chapter 7: Setting Parameters Network

Ether Packet Sz This parameter determines the maximum allowable size of the data packet sent from the terminal to the host. The possible values are: 1500, 512, 1024, 1490. The default value is 1500. Note: Normally, this parameter should be left at the default value of 1500. However, if you are using a token ring access point with direct telnet connections, the ‘Ether Packet Sz’ parameter should be set to 1490.

Mobile IP Mobile IP Home Agent IP Home Agent Disc Renew Threshld Rgstr Lifetime Rgstr Tmo Delay Reg Retry Count Reg RX Delay Mn Reg on Contact Grat Arp Max Ct Grat Arp RX Dly Simultan. Binds Max Num Binds Foreign Agents Home Agent SPI Home Agent Key Replay Protectn

N 20 1800 3000 3 3000 N 3 2000 N 1 10 333 N

Range see text Y/N 20-300 300-65535 1000-10000 1-10 1000-10000 Y/N 1-5 200-5000 Y/N 1-8 2-32 see text see text Y/N

Home Agent IP The valued entered for this parameter is the IP address of the Home Agent.

Home Agent Disc Setting this parameter to “Y” allows the terminal to send a registration packet to the Foreign Agent which, in turn, forwards the packet to the home network and the Home Agent(s). The terminal uses the Home Agent(s) response (which includes the Home Agent(s) IP address) to choose the Home Agent with which it will register.

Teklogix 7035, 8255 & 8260 Terminals User Manual

187

Page 214

Chapter 7: Setting Parameters Network

Renew Threshld The value assigned to this parameter indicates the number of seconds prior to “Regstr Lifetime” expiration that the terminal attempts a registration renewal. If, for example, this parameter is set to 20, the terminal will attempt to renew registration 20 seconds before “Regstr Lifetime” expires. When setting this parameter, keep in mind that if the value is too low, the session will expire, and the terminal will be unable to communicate with the host. On the other hand, if the value is too high, the terminal will attempt to register continually.

Rgstr Lifetime The value assigned to this parameter indicates the maximum registration lifetime, in seconds, that a terminal will be registered with the Home Agent. The default value for “Rgstr Lifetime” is 1800. The value 65535 is equivalent to “infinite”. If the terminal requests a value larger than the value configured for the Home Agent, the registration will be rejected, and the terminal will retry using a lower value.

Rgstr Tmo Delay The registration timeout delay is measured in milliseconds. Values lower than the protocol's absolute minimum for registrations retransmissions (one second) will be rejected.

Reg Retry Count The value entered for this parameter indicates the maximum number of registration retries on timeouts. Depending on your system, assigning a value from 3 (the default value) to 5 is recommended.

Reg RX Delay Mn The value assigned for ‘Reg RX Delay Mn’ determines the minimum delay between registration retransmissions. It is measured in milliseconds. Note: While a minimum of at least 1000 milliseconds is required for this parameter, the value assigned must not be higher than that assigned to the ‘Rgstr Tmo Delay’ parameter.

Reg On Contact When this parameter is set to “Y”, the terminal will not attempt to register until it receives an ‘advertisement’ from the Home or Foreign Agent.

188 Teklogix 7035, 8255 & 8260 Terminals User Manual