Chapter 7: Setting Parameters Serial
SI Prefix This parameter determines the start-of-message character on serial input. A value of “0” (zero) indicates no prefix. Enter an ASCII numeric equivalent from 0 to 255 to represent the start character.
SI Suffix This parameter determines the end-of-message character on serial input. A value of “0” (zero) indicates no suffix. Enter an ASCII numeric equivalent from 0 to 255 to represent the end character.
SI FnKey SI FnKey SI FnKey 0
Range 0-36
This parameter allows you to choose the function key you want appended to the serial input. For example, entering a value of “1” appends <F1> to serial input. A value of “0” (zero) appends <F0> – the <ENTER> key. To disable this feature so that a suffix is not added, set the “SI Fnkey” parameter to “N”.
Out This parameter enables serial port output fields.
SO Prefix This parameter determines the start-of-message character on serial output. A value of “0” (zero) indicates no prefix. Enter an ASCII numeric equivalent from 0 to 255 to represent the start character.
SO Suffix This parameter determines the end-of-message character on serial output. A value of “0” (zero) indicates no suffix. Enter an ASCII numeric equivalent from 0 to 255 to represent the end character.
Teklogix 7035, 8255 & 8260 Terminals User Manual
169
Page 196
Chapter 7: Setting Parameters Tests
7.7.2.5 Tests Tests AutoRep Fn AutoRep T/O
Range 1-36 0-255
1
0
AutoRep Fn This parameter determines which function key is sent to the host in auto reply mode. The value represents the number of the function key – not the ASCII decimal equivalent. After sending this key, the terminal locks and waits for the host to unlock the terminal. To disable “AutoRep Fn”, set the “AutoRep T/O” parameter to zero.
AutoRep T/O This parameter determines the time (in seconds) between the terminal unlocking and the next transmission of the function key specified by the “AutoRep Fn” parameter. A value of zero disables auto reply mode.
7.7.2.6 Scanner Scanner ContNxtField Append Enter Append F0 Mixed AIAG Rjct if Alpha Beam Lockout
Y
Y Y N N N
Range Y/N Y/N Y/N Y/N Y/N Y/N
ContNxtField This parameter only applies to string entry data. When enabled (set to “Y”), this parameter allows bar codes that are longer than the field length to continue in the next field. If “ContNxtField” is disabled (set to “N”) OFF data will flow into the next field.
Append Enter When enabled (set to “Y”), “Append Enter” causes an <ENTER> code to be appended to the bar code. The <ENTER> code completes the entry of the bar code and moves the cursor to the next field.
170 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 197
Chapter 7: Setting Parameters Fields
Append F0 When enabled (set to “Y”), this parameter causes an <F0> code to be appended to the bar code. The <F0> code completes the entry of the bar code data in the field.
Mixed AIAG When this parameter is enabled (set to “Y”), AIAG labels are always accepted and processed – even if mixed with keyboard input. The AIAG label can replace the partially entered keyboard data. If this parameter is disabled, AIAG labels are rejected if field entry is in progress.
Rjct if Alpha When the cursor is in a numeric field and “Rjct if Alpha” is enabled (set to “Y”), bar codes containing alphabetic characters are rejected.
Beam Lockout When enabled (set to “Y”), this parameter disallows scanner use when the current session is in “LOCK-H” mode.
7.7.2.7 Fields Fields Field Order Y Enter To F0 Y Enter On Arr Y Entry Mode field Open Fky Only N Video » All Fld Video Y Ign Bcode_fld N Enh Edit Mode N Valid Numerics +-%*/.,$
Range Y/N Y/N Y/N see text Y/N see text Y/N Y/N Y/N see text
Field Order This parameter determines the mode of cursor movement between fields. The next field can be defined by location on the screen or by the assignment of field numbers. When enabled (set to “Y”), the cursor moves according to field location. If disabled (set to “N”), the cursor moves according to the numeric order of the fields.
Teklogix 7035, 8255 & 8260 Terminals User Manual
171
Page 198
Chapter 7: Setting Parameters Fields
Enter To F0 The <ENTER> key normally enters data into a field and moves the cursor to the next field. However, some applications require that the <ENTER> key start a transmission from the terminal. When enabled (set to “Y”), this parameter causes the <ENTER> key to be interpreted as <F0> which starts a transmission.
Enter On Arr When this parameter is enabled (set to “Y”), the arrow keys can be used to complete data entry into a field.
Entry Mode “Entry Mode” parameters allow you to select a data entry mode. The modes are: insert, replace, field and fcursor. “TESS Edit Modes And Cursor Movement” on page 97 describes these modes in detail.
Open Fky Only When this parameter is enabled (set to “Y”), the screen is open for function keys only, and the cursor is not positioned. When this parameter is disabled, the screen is open for data entry, and the cursor is placed in the first field (if it exists).
Video Video Blink Bold Reverse
BLNK NONE REV
Range see text see text see text
Blink The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Blink” TESS attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).
Bold The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Bold” TESS attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).
172 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 199
Chapter 7: Setting Parameters Features
Reverse The value assigned to the “Reverse” parameter specifies the actual video attributes to be assigned to fields created with the “Reverse” TESS attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).
All Fld Video Usually, the video attributes apply only to the text that is in an entry field. When this parameter is enabled (set to “Y”), the entire field (including blanks) takes on the video attributes. Some systems use this option to identify empty entry fields with reverse video.
Ign Bcode_fld When this parameter is enabled (set to “Y”), fields that were defined as “bar code only” accept data from the keyboard as well as the bar code reader. In effect, they behave as data entry fields.
Enh Edit Mode This mode provides extended (enhanced) functions to users of Teklogix’ IBM 5250 terminal emulation. When this parameter is enabled (set to “Y”), the arrow keys move the cursor anywhere on the screen, unrestricted by fixed or entry fields. Certain 5250 emulation keys (e.g. Field Exit) that were originally available only when “Enh Edit Mode” was set to “Y” are now active at all times in TESS applications. Refer to “IBM 5250 Emulation Keys” on page 96 for details about these keys.
Valid Numerics Numbers from 0 to 9 are always considered valid characters for TESS numeric fields. This parameter allows other printable characters to be defined as numeric characters in addition to 0 through 9. Any displayable character can be defined as numeric.
7.7.2.8 Features Features Kbd Locked Disable Beep
N N
Range Y/N Y/N
Teklogix 7035, 8255 & 8260 Terminals User Manual
173
Page 200
Chapter 7: Setting Parameters View Manager
Kbd Locked This parameter allows you to lock (set to “Y”) or unlock (set to “N”) the keyboard for all alphanumeric input in TESS. When the keyboard is locked, the function keys, arrow keys and the <ENTER> key are still functional. The terminal emits an error beep if a character is rejected because the keyboard is locked. Changes to this parameter take effect only after the terminal is reset.
Disable Beep Setting this parameter to “Y” disables the beep generated by the ‘o’, ‘G’ and ‘#’ TESS commands. Keep in mind that Error and Scan beeps are not disabled.
7.8 View Manager View Manager Anchor View N X-origin 1 Y-origin 1 Use Increment N X-increment 5 Y-increment 5 Display Shift Y Custom Chars » Font Override Y»
Range Y/N 1-80 1-24 Y/N 1-40 1-12 Y/N see text see text
Anchor View When enabled (set to “Y”), this parameter locks the display at a defined location on the screen, preventing it from shifting when the cursor is moved. The “X-origin” and “Y-origin” coordinates specify where the screen origin, the upper-left corner of the screen, will be fixed.
X-origin And Y-origin The “X-origin” parameter is used to specify the column to which the upper left corner of the screen will be anchored. The “Y-origin” parameter is used to specify the row coordinate to which the screen will be anchored.
174 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 201
Chapter 7: Setting Parameters View Manager
Use increment When “Use increment” is enabled (set to “Y”) and the cursor is moved off the display, the screen contents shift by the values specified in the “X-increment” and “Y-increment” parameters.
X-increment This parameter determines the number of spaces the screen shifts once the cursor moves out of view. The value assigned here doesn’t take effect until “Use Increment” is set to “Y”.
Y-increment This parameter determines the number of spaces the screen shifts once the cursor moves out of view. The value assigned here doesn’t take effect until “Use Increment” is set to “Y”.
Display Shift If this parameter is enabled (set to “Y”), the display in application screens shifts so that there are no blank columns on the left-most side of the display.
Custom Chars Custom Chars 0 0 • • • 0 This parameter is used to create a list of custom characters (to a maximum of 20 characters) that are not normally available directly from the keyboard. To create a character: • Type the Unicode value of the character you want to create. Note: If the character you select does not exist in the host character set, it cannot be sent to the host application. Once you’ve created this list of characters, you can access the list from within a TESS or ANSI session as follows: • Press <ALT> a to display your list of custom characters. • Use the arrow keys to highlight the character you require, and press <ENTER> to select it. Teklogix 7035, 8255 & 8260 Terminals User Manual
175
Page 202
Chapter 7: Setting Parameters GPS – Global Positioning System Receiver
Font Override Font Override Font Code 0 ... is font 18x32 Font Code 1 ... is font 18x32 Font Code 2 ... is font 10x26 Font Code 3 ... is font 18x32 Font Code 4 ... is font 8x20 This parameter is used to redefine the font to which 5 different font codes refer. “Font Override” is enabled (set to “Y”) by default and is set to values equivalent to those used by 7030/8055/8060 generation terminals.
7.9 GPS – Global Positioning System Receiver Important:
GPS is only available for 7035 WAN hand-helds – terminals equipped with Wide Area Network radios.
The parameters in the GPS menu are used to configure the GPS receiver. The receiver can be programmed to transmit one or more NMEA sentences to the terminal once every “Tx period” seconds. Note: The terminal will transmit sentences from the GPS without modifications. For more information on the exact formats of the GPS sentences, review the documentation included with your GPS receiver. GPS Range GGA Y Y/N GLL N Y/N RMC N Y/N VTG N Y/N Tx Period 10 1-255
176 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 203
Chapter 7: Setting Parameters Ports– Serial 1 And Console 2
GGA When GGA is enabled (set to “Y”), a “Global Positioning System Fix Data” message can be transmitted from the GPS receiver. The data available in a GGA message includes: Time, Latitude, Longitude, Altitude, Signal Quality, Number of Satellites and Horizontal Dilution of Precision.
GLL Setting this parameter to “Y” allows a “Geographic position, Latitude and Longitude” sentence to be transmitted from the GPS receiver. The data available in a GLL message includes: Time, Latitude, Longitude, Status and Mode.
RMC Setting RMC to “Y” allows a “Recommended minimum specific GPS/Transmit data” sentence to be transmitted from the GPS receiver. The data available in a RMC message includes: Time, Date, Latitude, Longitude, Speed (knots), Direction, Magnetic Variation and Mode.
VTG When VTG is enabled (set to “Y”), the “Track made good and ground speed” sentence can be transmitted from the GPS receiver. The data available in a VTG message includes: Speed (knots), Speed (kilometers per hour) and Direction.
Tx Period The value assigned to this parameter determines the rate at which the enabled sentences are transmitted. For example, a value of 10 means that all enabled sentences will be transmitted at the beginning of each 10 second period.
7.10 Ports– Serial 1 And Console 2 Ports Serial 1 Parameters Console 2 Parameters
Print » Disable »
7.10.1 Serial 1 And Console 2 Peripheral Options The “Serial 1” (COM1) and “Console 2” (COM2) options allow you to enable, disable and specify the accessories attached to these ports. Possible values include:
Teklogix 7035, 8255 & 8260 Terminals User Manual
177
Page 204
Chapter 7: Setting Parameters Serial 1 And Console 2 Parameter Settings Serial 1 – Disable, Enable, Print, Scanner, Output and IrDA Printer. Console 2 – Disable, Enable, Print, Scanner, Scan-See, NOMAD and GPS.
To scroll through the options for each port: • Press the <RIGHT> or <LEFT> arrow key. Important:
If you choose Disable, the corresponding port parameters will not take effect.
These ports operate differently depending on the accessories selected. • • • • •
• •
“Print” – all TESS print operations are directed to the port. All ANSI media copy operations to the “primary port” are directed to this port. “Scanner” – TESS and ANSI accept scanner input from the port. “Scan-See” – TESS and ANSI accepts input from the Scan-See through Console 2 port. (This option is not available for the Serial 1 port.) “Nomad” – TESS and ANSI accepts input from the Nomad scanner through Console 2 port. (This option is not available for the Serial 1 port.) “Output” – TESS pass-through operations and serial output fields are directed to Serial 1 port. (This option is not available for the Console 2 port.) “IrDA Printer” – A serial peripheral cannot be used while the IrDA port is in use. (This option is not available for the Console 2 port.) “GPS” – TESS accepts input from the GPS receiver through Console 2 port (This option is not available for the Serial 1 port.)
7.10.2 Serial 1 And Console 2 Parameter Settings Since the parameters for the “Serial 1” and “Console 2” ports are identical in most cases, they are discussed in one section. Any differences are clearly indicated. Important:
The most significant difference between the “Serial 1” and “Console 2” port parameters is that the Scan-See menu is only available in the Console 2 “Parameters” menu.