Chapter 7: Setting Parameters Keyboard Local:
In this mode, any character entered using the keyboard is displayed before being sent to the host. Certain keys cause additional action at the terminal, as shown in Table 7.2 on page 159.
Host:
In this mode, the terminal sends all keyboard entries to the host and displays only data received from the host.
Key
Function
ENTER
In Newline mode, this key moves the cursor to the first column of the next line. In line feed mode, this key moves the cursor to column one of the current line.
CTRL-G (Bell)
The terminal beeps.
CTRL-H (Backspace)
The cursor moves back one space.
CTRL-I (Tab)
The cursor moves to the next horizontal tab stop.
CTRL-J (Line Feed) CTRL-L (Form Feed) CTRL-K (Vertical Tab) DEL
The cursor moves down one line in the same column. The cursor moves down to the next line with a vertical tab set. This key deletes the character to the left of the cursor and moves the cursor to the left by one position.
Table 7.2 Function Of Special Keys In Local Echo Mode
DEL Key This parameter determines which character is sent to the host – DEL (delete) or BS (backspace). The host interprets how it will respond to the code. The selection made at this parameter does not affect how the <DEL> key operates at the terminal.
PrintScreen Key This parameter determines the “hot-key” that will print the screen contents through the terminal serial port. The default is 16 or <CTRL> P. Note: The terminal’s serial port must be set for ‘Print’. Refer to “Serial 1 And Console 2 Peripheral Options” on page 177.
Teklogix 7035, 8255 & 8260 Terminals User Manual
159
Page 186
Chapter 7: Setting Parameters Serial
Insert When this parameter is enabled (set to “Y”), the keyboard operates in insert mode. In insert mode, the graphic symbol of a graphic character, or a control function for which graphical representation is required is inserted at the cursor. If the “Insert” parameter is disabled (set to “N”), the keyboard operates in replace mode. In replace mode, the graphic symbol or control function replaces (or, depending upon the implementation, is combined with) the graphic symbol at the cursor.
Newline When this parameter is disabled (set to “N”), a LF character received from the host causes the cursor to move down one line in the same column. In addition, the <ENTER> key transmits a CR. When enabled (set to “Y”), an LF character received from the host causes the cursor to move to the first column of the next line. The <ENTER> key transmits both a CR and an LF.
DEC Cursor Keys This parameter can be set to either Cursor Mode or Appl. Mode. Cursor Mode causes the cursor keys to generate ANSI cursor control sequences. Application Mode causes the cursor keys to send application control functions.
7.7.1.6 Serial Serial Async In Start End
N 0 0
Range Y/N 0-255 0-255
Async In When this parameter is enabled (set to “Y”), the serial (async) port is ready to receive input at all times.
Start/End The start character is added to the beginning of the data received from the serial (async) port. The end character is added to the end of the data received.
160 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 187
Chapter 7: Setting Parameters TESS Settings
7.7.2 TESS Settings TESS Auto Term# Terminal # Host Conn Screen Characters Serial Tests Scanner Fields Features
Y» 1 » » » » » » » »
Range see text see text see text see text see text see text see text see text see text see text
Each session you create has its own “Settings” parameters. Additional TESS information is documented in Chapter 5: TESS Operations.
Auto Term# Note: Refer to “Group” on page 161 for additional instructions. When this parameter is set to “Y”, a unique terminal number is assigned for the current TESS session. If “Auto Term#” is set to “Y”, any value assigned to the “Terminal #” parameter is ignored. Note: “Auto Term#” is available when 802.IQv2 is assigned to the “Host Conn” parameter (page 162) or when 802.IQv1 is enabled in the Radio Menu (“802.IQ v1” on page D-6).
Group Auto Term# Group 1
Range 1-5
When “Auto Term#” is set to “Y”, the ‘Group’ parameter is used to identify the group or pool of terminal numbers from which an auto-address is chosen.
Terminal # For every application session you create, the terminal number assigned in the “Terminal #” parameter must be non-zero and unique. This parameter defines the terminal number for the TESS session and uniquely identifies all transmissions to and from the terminal.
Teklogix 7035, 8255 & 8260 Terminals User Manual
161
Page 188
Chapter 7: Setting Parameters Host Conn Other applications running in the terminal, such as an ANSI session or another TESS session must each have a different terminal number. In addition, each Teklogix terminal using the radio link must have a unique terminal number.
7.7.2.1 Host Conn Important:
This parameter is not available when the terminal is operating with a narrow band radio. Range Host Conn Conn Type 802.IQv2 802.IQ, 9010t Settings » see text
Conn Type The options for this a parameter vary depending on the type of application you are running – ANSI or TESS. For TESS applications, this parameter allows you to choose one of the following types of connections: 802.IQv2 or 9010t (TCP Direct). In either case, the terminal will be communicating through a controller or an SDK. (For details about ANSI options, review “Host Conn” on page 150.)
Settings Note: The “Settings” sub-menu is only available when 9010t is selected as the “Conn Type”. Range Settings Host see text Port 9999 0-9999
Host This parameter is used to assign a host IP address using the format ###.###.###.###
Port “Port” specifies the 9010t (TCP Direct) port number. By default, the 9010t port is assigned the value 9999.
162 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 189
Chapter 7: Setting Parameters Screen
7.7.2.2 Screen Screen Columns Rows Scroll Mode Pages Saved App. Parameter Font Size Cursor Type Softkeys
Range 80
24 Normal 16 -1 18x20 Underline »
20..132 4..60 Normal, Field, Origin 1..16 -1..79 see text Underline, Block see text
Columns This parameter defines the logical page width (in characters) used by the host computer application. Emulator systems trim the host application screens to this width. This page width cannot be smaller than the width of the terminal display. Display panning is used if the page is wider than the display. Note: The value in this parameter must be an even number.
Rows This parameter defines the logical page length (in lines) used by the host computer application. Emulator systems trim the host application screens to this length. This page length cannot be smaller than the length of the terminal’s display. Display panning is used if the page is longer than the display. Note: The value in this parameter must be an even number.
Scroll Mode This parameter allows you to determine how the information in the display window moves on the screen. The options are: Normal, Field and Origin. If Normal is assigned to this parameter, the display window follows the cursor. If Field is chosen, the display window moves to the left after entering a new entry field. If Origin is chosen, the display window moves to the origin (upper-left corner) after “LOCK-H” or “LOCK-B” messages.
Teklogix 7035, 8255 & 8260 Terminals User Manual
163
Page 190
Chapter 7: Setting Parameters Screen
Pages Saved This parameter determines the number of pages that can be stored and recalled at the terminal. Storing frequently used page data at the terminal reduces the need for the host to retransmit complete page data over the radio link. Retransmitting data can reduce the system response time. Increasing the number of saved pages decreases the available memory for other functions.
App. Parameter The “Application” parameter is sent to the host system as part of the response to the TESS query command. Enter zero if this parameter is not used.
Font Size This parameter is used to change the font size displayed within the TESS applications. Font sizes are represented in lines x characters (rows x columns). Font availability varies depending on the type of terminal used and the font package installed in the terminal. • Press the <RIGHT> arrow key to scroll through the options.
Cursor Type This parameter allows you to choose how you want the terminal cursor displayed. You can choose either an Underline or Block cursor. • Press the <RIGHT> arrow key to scroll through and choose an option.
Softkeys Note: This menu uses string entry fields. For detailed information about completing this type of field, refer to “String Entry Parameters” on page 117. Softkeys F1 F2 F3 F4 Important:
The sample menu above reflects the 7035 hand-held softkey options. The Softkey menu for 8255 and 8260 vehicle-mount terminals equipped with 10 function key keyboards provide 10 softkey labels – F1 to F10. Vehicle-mounts with 6 function key keyboards list 6 softkey labels in this menu.
164 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 191
Chapter 7: Setting Parameters Characters Softkeys are function keys that have been programmed to perform specific actions in your application. These keys are identified through softkey labels – reverse video labels that are displayed at the bottom of the terminal screen. These softkey labels can be reconfigured using the menu attached to this parameter. To edit a label: • Position the cursor in the appropriate function key field within the Softkey menu, and type a new name – preferably one that describes the corresponding key’s function. Note: Although you can enter up to 8 characters for each softkey label, the text will be shortened to better fit in the available space on your display.
7.7.2.3 Characters Characters Invis. 42 NULL 46 Char Set » Err Func Key 0 V Match Chr 0 H Match Chr 0 Upper Case N
Range 0-255 0-255 see text 0-255 0-255 0-255 Y/N
Invis In TESS applications, some fields may be set as “invisible” or “non-display” fields. This parameter determines the character that will mask the actual text typed. For example, this feature is often used in password entry fields where the actual text typed is replaced by asterisks. * (asterisk) The ASCII equivalent for this character is 42.
NULL This parameter specifies the character that identifies empty entry fields. (Note that positions containing spaces are not considered empty.) Enter the ASCII equivalent of this character. The most commonly used characters are: _ (underline) The ASCII equivalent for this character is 95. . (period) The ASCII equivalent for this character is 46.
Teklogix 7035, 8255 & 8260 Terminals User Manual
165
Page 192
Chapter 7: Setting Parameters Characters
Char Set Char Set ISO N» IBM Y» DEC N» Misc. N» This menu contains the character sets available with your Teklogix terminal. The “Y” or “N” displayed next to a character set indicates whether or not a character set has been activated within this group. For example, in the sample menu above, “Y” next to IBM indicates that a character set has been activated in this group. To choose a character set: • Position the cursor on the appropriate item – for example, ISO – and press <F1> to display the character set options. • To activate a character set, press the <RIGHT> or <LEFT> arrow key to set it to “Y”.
Err Func key This parameter defines the function key that interrupts the normal sequence of a terminal and causes an Error Reply message to be returned to the host. Enter the number of the function key to be used as the Error function key (e.g., “1” for function key 1). This parameter should be set to zero unless there is a system requirement for Error Reply messages. When the Error function key is entered, the terminal abandons all queued procedures and TESS commands and returns an Error Reply message, with a milestone, to the host. The host must respond with a milestone acknowledge before the terminal accepts further TESS commands.
V Match Chr This parameter enables visible field matching and defines the character that identifies visible field match data from the host. Field matching allows the host to pre-load data into an entry field that is compared with the user’s input. The terminal beeps if the entered data does not match. Visible field matching means that the data to be matched is displayed in the entry field. Enter the decimal value for the ASCII character from 0 to 255 that will be used by the host to identify visible match field data. Enter 0 (zero) to disable this feature. Note: Another method of field matching is available directly through the TESS data stream. 166 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 193
Chapter 7: Setting Parameters Serial
H Match Chr This parameter enables hidden field matching and defines the character that identifies hidden field match data from the host. Field matching allows the host to pre-load data into an entry field that is compared with the user’s input. The terminal beeps if the entered data does not match. Hidden field matching means that the data to be matched is not displayed in the entry field. Enter the decimal value for the ASCII character from 0 to 255 that will be used by the host to identify hidden match field data. Enter 0 (zero) to disable this feature. Note: Another method of field matching is available directly through the TESS data stream.
Upper Case When this parameter is set to “Y”, lowercase input is converted to uppercase.
7.7.2.4 Serial Serial In SI Mode SI Prefix SI Suffix SI Fnkey Out SO Prefix SO Suffix
Range N Field 10 13 N» Y 10 13
Y/N Field, Command 0-255 0-255 see text Y/N 0-255 0-255
Note: This menu uses “string entry” parameters. For detailed information about entering data in this type of parameter, refer to “String Entry Parameters” on page 117.
In This parameter enables the serial port input fields. If enabled (set to “Y”), the TESS application has exclusive use of the serial port. Data entered in these fields must begin with a SI Prefix and end with a SI Suffix character.
SI Mode TESS supports communication to and from the terminal serial port using two methods: Command and Field. When SI Mode is set to field, serial input is displayed in serial-input fields and serial output is displayed in serial-output fields on the current TESS page. The serial input fields are defined in the System Network Teklogix 7035, 8255 & 8260 Terminals User Manual
167
Page 194
Chapter 7: Setting Parameters Serial Controller configuration (see ‘9300 Network Controller User Manual” – PN 80409 and “Teklogix Screen Subsystem (TESS) Programmer’s Manual” – PN 79186 to review TESS field extended attributes and the bits ‘b’ command). The data is sent to the host as field data. Serial output with controller emulations is provided through the passthru-printing feature. If a TSDK (Teklogix Software Development Kit) is used to develop your application, the serial-input and serial-output fields are configured as the screen sets are created using the Wintsf screen editor. A serial-in field is an ‘Entry’ field with the serial attribute box checked and a serial-out field is a ‘Fixed’ field with the serial attribute box checked (refer to the “7035/8255/8260 Software Development Kit User Manual” – PN 80455). Important: If you are using serial-input fields, make sure the ‘SI Mode’ parameter is set to field. When ‘SI Mode’ is set to command, serial input is not displayed on the terminal screen. It is transmitted directly with a TESS response command. To use this mode, the TSDK TESS message macro TESS_RESP_SERIAL_INPUT will identify the received message as input data from the terminal serial port. Serial Notes: 1. Field mode is supported by both emulations and Software Development Kits. Command mode is only supported by Software Development Kits. 2. You can configure the terminal to automatically transmit data received through the serial port without user intervention. When ‘SI Mode’ is set to Field, automatic transmission of serial data can be done by setting the ‘SI Fnkey’ parameter to the desired function key. When ‘SI Mode’ is set to Command, automatic transmission is based on the configuration of the ‘Port’ parameters as well as the ‘SI Prefix’ and ‘SI Suffix’ values. If the suffix and prefix values are not used (set to zero), serial data is transmitted after the ‘Input Tmo’ value (in the ‘Ports’, ‘Serial 1’ menu) has expired. If the serial data is received in bursts and the ‘Input Tmo’ value expires between bursts, the serial data may be transmitted in several packets. If prefix and suffix values are used for SI data, the ‘Input Tmo value will not affect the transmission of the data from the terminal Serial data is passed to the TESS session after the ‘Serial 1’ port ‘Input Tmo’ value has expired and/or the prefix and suffix characters are received.