Page 175

Chapter 7: Setting Parameters ANSI Settings

Name And Type Up to four applications can be entered in this parameter. The “Name #” parameter must be completed with a name that is meaningful to the operator. The “Type #” field indicates the type of session you will be running. • In a “Name #” field, type a name that is meaningful to the operator. • The available options for the “Type #” field are TESS and ANSI. Type the appropriate application type in this field using either uppercase, lowercase or a combination. • To display the “Settings” menu for your application, position the cursor on “Settings”, and press <F1> – the NEXT key. Note: Before you can access the “Settings” menu, you must first complete the “Name” and “Type” fields.

7.7.1 ANSI Settings Ansi Auto Term# Terminal # Host Conn Screen Host Char Set Transmit Keyboard Serial

Y» 1 » » » » » »

Range see text 1-1024 see text see text see text see text see text see text

Each session you create has its own “Settings” parameters. Additional ANSI information is documented in Chapter 6: ANSI Operations.

Auto Term# Note: Refer to “Group” on page 150 for additional instructions. When this parameter is set to “Y”, a unique terminal number is assigned for the current ANSI session. If “Auto Term#” is set to “Y”, any value assigned to the “Terminal #” parameter is ignored. Note: “Auto Term#” is available when 802.IQv2 is assigned to the “Host Conn” parameter (page 150) or when 802.IQv1 is enabled in the Radio Menu (“802.IQ v1” on page D-6).

Teklogix 7035, 8255 & 8260 Terminals User Manual

149

Page 176

Chapter 7: Setting Parameters Host Conn

Group Auto Term# Group 1

Range 1-5

When “Auto Term#” is set to “Y”, the ‘Group’ parameter is used to identify the group or pool of terminal numbers from which an auto-address is chosen.

Terminal # For every application session you create, the terminal number assigned in the “Terminal #” parameter must be non-zero and unique. This parameter defines the terminal number for the ANSI session and uniquely identifies all transmissions to and from the terminal. Other applications running in the terminal, such as a TESS session or another ANSI session must each have a different terminal number. In addition, each Teklogix terminal using the radio link must have a unique terminal number.

7.7.1.1 Host Conn Important:

This option is not available when the terminal is operating with a narrow band radio. Range Host Conn Conn Type Telnet 802.IQv2, 9010t, Telnet Settings » see text

Conn Type The options for this a parameter vary depending on the type of application you are running – ANSI or TESS and the type of radio installed in your terminal. For ANSI applications, this parameter allows you to choose one of the following types of connections: 802.IQv2, 9010t (TCP Direct) or Telnet. Keep in mind that choosing Telnet allows the terminal to communicate directly with the host.

150 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 177

Chapter 7: Setting Parameters Host Conn

Settings Note: The “Settings” sub-menu is not available when 802.IQv2 is selected as the “Conn Type”. In addition, this sub-menu varies depending on which option you’ve selected – Telnet or 9010t. Range Telnet Settings Host see text Port 23 0-32767 ENTER Pmpt Press ENTER to connect see text ESC Prompt Press ESC to cancel see text Auto Login N» Y/N FK Remap N Y/N

9010t Settings Host Port

9999

Range see text 0-9999

Host This parameter is used to assign a host IP address using the format ###.###.###.### or a host name if DNS is used.

Port “Port” specifies the 9010t (TCP Direct) or Telnet port number. The default 9010t port number assigned is 9999, the maximum allowable value. The default Telnet port number assigned is 23 with a maximum allowable value of 32767.

ENTER Pmpt This string indicates that the terminal is waiting for the user to press <ENTER> at the time of connection.

ESC Prompt This string indicates that the user can press the <ESC> key to terminate a connection attempt before the connection is established.

Teklogix 7035, 8255 & 8260 Terminals User Manual

151

Page 178

Chapter 7: Setting Parameters Host Conn

Auto Login Auto Login Login Prompt Login Password Prompt Password Password Echo Login Failed gin:

word: Y incorrect

Range see text see text see text see text Y/N see text

The “Auto Login” parameters are used to define whether or not the terminal will attempt to log in automatically. The Auto Login sequence is as follows: 1. 2. 3. 4. 5. 6.

Host sends “Login Prompt”. Terminal responds with “Login”. Host sends “Password Prompt”. Terminal responds with “Password”. Host may send password echo. Terminal ignores password echo if “Password Echo” is set to “Y”, otherwise skip to step 7. 7. Terminal looks for “Login Failed” in next transmission from host. 8. Login successful or Login failed and return to step 1.

Login Prompt When the terminal receives the string assigned to this parameter, it will respond with “Login”.

Login The terminal responds with this string when it receives a “Login Prompt”.

Password Prompt When the terminal receives this string, it responds with a “Password”.

Password The terminal responds with this string when it receives a “Password Prompt”.

152 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 179

Chapter 7: Setting Parameters Screen

Password Echo When this parameter is set to “Y”, the host will echo data back to the terminal after receiving a “Password”.

Login Failed When the terminal receives this string, it assumes that the login attempt has failed and returns to the “Enter Pmpt”.

FK Remap Setting this parameter to “Y” allows the terminal to redefine the character sequence sent by ANSI function keys. When “FK Remap” is set to “Y”, the “ANSI FK Remap” menu becomes available in the root “Parameters” menu. Refer to “ANSI FK Remap” on page 196 for additional details.

7.7.1.2 Screen Screen Pages Columns Rows Auto Wrap Disp Ctrls Font Size Cursor Type Softkeys Video

4 80

24 Y N 18x20 Underline » »

Range 0-16 80 or 132 4-60 Y/N Y/N see text Underline Block see text see text

Pages This parameter defines how many pages are accessible to application programs. The ANSI control functions, Next Page (NP) and Previous page (PP), are used to select another page. These pages are independent of each other so that if lines of text scroll off a page, the other pages are unaffected. Important:

There is no error indication from the terminal if the memory required by the selected number and size of pages exceeds the memory available in the terminal.

Teklogix 7035, 8255 & 8260 Terminals User Manual

153

Page 180

Chapter 7: Setting Parameters Screen

Columns This parameter defines the logical page width (in characters) used by the host computer application. Emulator systems trim the host application screens to this width. This page width cannot be smaller than the width of the terminal display. Display panning is used if the page is wider than the display.

Rows This parameter defines the logical page length (in lines) used by the host computer application. Emulator systems trim the host application screens to this length. This page length cannot be smaller than the length of the terminal’s display. Display panning is used if the page is longer than the display. Note: The value in this parameter must be an even number.

Auto Wrap If “Auto Wrap” is disabled (set to “N”), characters received when the cursor is at the right edge of the screen replace the previously displayed characters. If “Auto Wrap” is enabled (set to “Y”), the cursor wraps to the next line when the current line is filled. The display scrolls up if the cursor is at the bottom margin.

Disp Ctrls This parameter is used to debug information from the ANSI host. Instead of acting on the ANSI C0 and C1 controls, a character description of them is displayed on the terminal screen.

Font Size This parameter is used to change the font size displayed within the ANSI application on 7035 hand-helds and 8255 and 8260 vehicle-mounts. Font sizes are represented in lines x characters (rows x columns). Font availability varies depending on the type of terminal used and the font package installed in the terminal. •

Press the <RIGHT> arrow key to scroll through the options.

Cursor Type This parameter allows you to choose how you want the terminal cursor displayed. You can choose either an Underline or Block cursor. •

Press the <RIGHT> arrow key to scroll through and choose an option.

154 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 181

Chapter 7: Setting Parameters Screen

Softkeys Note: This menu uses string entry fields. For detailed information about completing this type of field, refer to “String Entry Parameters” on page 117. Softkeys F1 F2 F3 F4 Important:

The sample menu above reflects the 7035 hand-held softkey options. The Softkey menu for 8255 and 8260 vehicle-mount terminals equipped with 10 function key keyboards provide 10 softkey labels – <F1> to <F10>. Vehicle-mounts with 6 function key keyboards list 6 softkey labels in this menu.

Softkeys are function keys that have been programmed to perform specific actions in your application. These keys are identified through softkey labels – reverse video labels that are displayed at the bottom of the terminal screen. These softkey labels can be reconfigured using the menu attached to this parameter. To edit a label: •

Position the cursor in the appropriate function key field within the Softkey menu, and type a new name – preferably one that describes the corresponding key’s function.

Note: Although you can enter up to 8 characters for each softkey label, the text will be shortened to better fit in the available space on your display.

Video Video Bold Blink Reverse Underline

NONE BLNK REV ULIN

Range see text see text see text see text

Bold The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Bold” ANSI attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal). Teklogix 7035, 8255 & 8260 Terminals User Manual

155

Page 182

Chapter 7: Setting Parameters Host Char Set

Blink The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Blink” ANSI attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).

Reverse The value assigned to the “Reverse” parameter specifies the actual video attributes to be assigned to fields created with the “Reverse” ANSI attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).

Underline The value assigned to this parameter specifies the actual video attributes to be assigned to fields created with the “Underline” ANSI attribute – that is, “BLNK” (blink), “ULIN” (underline), “REV” (reverse) or “NONE” (normal).

7.7.1.3 Host Char Set The ‘Char Set’ menu allows you to specify a character set in the ‘Lower’ and ‘Upper’ character tables. Char Set Lower VT220 Fren Cdn. Upper Arabic IR-127

Note: When an 8-bit set is selected from the ‘Lower’ character set, the ‘Upper’ character set cannot be changed. To choose ‘Lower’ and ‘Upper character sets: • •

Position the cursor on the ‘Lower’ or ‘Upper’ parameter, and press the <RIGHT> or <LEFT> arrow key to display the character set options. Press <F4> to save your selection to memory.

Important:

When a character sent from the host cannot be displayed, a rectangular box is used as a substitute.

156 Teklogix 7035, 8255 & 8260 Terminals User Manual

Page 183

Chapter 7: Setting Parameters Transmit

7.7.1.4 Transmit Transmit Xmit Count 99 Xmit Wait 1 Dev Attr Auto-Ans 7 Bit Y

Range 0-99 0-999 see text see text Y/N

Xmit Count This parameter determines how many characters from the keyboard or scanner are buffered by the terminal before being transmitted to the host. If 0 (zero) is selected, the terminal transmits only according to the “Xmit Wait” parameter. If the ANSI block mode features are used, this parameter should be set to 99. Note: If the terminal is not in local edit mode, the <ENTER>, arrow, <CTRL>, and function keys cause an immediate radio transmission regardless of the “Xmit Count” parameter setting.

Xmit Wait This parameter determines the length of time the terminal collects keystrokes before transmitting them to the host. This value is specified in increments of one 10th of a second (i.e., a value of 10 represents 1 second). If 0 (zero) is selected, the terminal transmits only according to the “Xmit Count” parameter. Note: If the terminal is not in local edit mode, the <ENTER>, arrow, <CTRL>, and function keys cause an immediate radio transmission regardless of the “Xmit Wait” parameter setting.

Dev Attr This parameter specifies a device attribute string. This string can be up to 39 characters long. The terminal sends this string to the host when it receives a DA or DECID control. Whether or not this parameter is set is dependent on the requirements of the host computer.

Teklogix 7035, 8255 & 8260 Terminals User Manual

157

Page 184

Chapter 7: Setting Parameters Keyboard

Auto-Answer This string can be up to 39 characters long and is sent by the terminal as a reply to an “ENQ” character from the host. The “Auto-Answer” string is programmable in the same manner as the keyboard macros. For example, this string can be used to automatically send the user name and password when logging into the host. Refer to "String Entry Parameters" on page 117 to 118 for detailed information.

7 Bit If this parameter is set to ‘Y’, the terminal transmits 7-bit controls. When set to ‘N’, the terminal transmits 8-bit controls. ‘7 Bit’ is set to ‘Y’ by default.

7.7.1.5 Keyboard Keyboard Echo Mode DEL Key PrintScreen key Insert Newline DEC Cursor Keys

Range Smart BS 16 N N Cursor Mode

Smart, Local, Host BS, DEL 0-26 Y/N Y/N Cursor Mode, Appl. Mode

Echo Mode The available echo modes are: Smart:

Important:

This mode reduces or eliminates the delay between typing a character on the keyboard and displaying the character echoed by the host computer. The terminal displays all printable characters on the screen before sending them to the host. The terminal compares the characters echoed by the host to the characters placed on the page and alters the display if the host echoes are different. The maximum number of characters waiting for echo is 25. Any additional characters are sent to the host but are not displayed. When the terminal is in insert mode, smart echo is disabled.

To suspend Smart echo mode if, for example, you are entering a password, press <ALT> and type ‘.’ (period). Characters will be replaced with a series of periods until you press the <ENTER> key.

158 Teklogix 7035, 8255 & 8260 Terminals User Manual