Page 165
Chapter 7: Setting Parameters Code 39
Field Size The field size is the length of the field after the first character is stripped and the prefix and suffix characters are added. If the field size is non-zero, only bar codes of that length are passed through.
Prefix Char This character, if non-zero, is added before a successfully decoded bar code. Enter the ASCII decimal equivalent of this character. Enter a value of “0” (zero) if no prefix is to be added.
Suffix Char This character, if non-zero, is added after a successfully decoded bar code. Enter the ASCII decimal equivalent of this character. Enter a value of “0” (zero) if no suffix is to be added.
Strip Leading This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Notes: 1. The appended character is treated as any other keyboard character. For example, if <DEL> is pressed, the usual action for that key is performed. With ANSI emulation, the terminal transmits the escape sequence associated with the function immediately after the bar code data. 2. For Code 39 bar codes, the “AIAG Strip” is performed before the “Strip Leading”.
Strip Trailing The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
Teklogix 7035, 8255 & 8260 Terminals User Manual
139
Page 166
Chapter 7: Setting Parameters Code 128
7.6.3.2 Code 128 Code 128 Type Standard Include Sym N Size/Chars »
Type When using Code 128, you can choose the type of bar code variation the scanner will recognize. The options available are Standard, UCC and EAN/UCC. These options are described below.
Standard Set “Standard” to “Y” if Code 128 is desired.
UCC “UCC” is a variation of Code 128.
EAN/UCC Set “EAN/UCC” to “Y” to enable this type of bar code. “EAN/UCC” bar codes include group separators and start codes.
Include Sym Enabling (setting to “Y”) “Include Sym” causes the group separator(s) and start code contained in this type of bar code to be displayed on the terminal screen.
Size/Chars See “Size/Chars” on page 138.
7.6.3.3 EAN 13 EAN 13 Inc Country Include Chk Size/Chars Addendum
Y Y » Disabled
Inc Country If this parameter is enabled (set to “Y”), the country code is included with the decoded bar code data. 140 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 167
Chapter 7: Setting Parameters EAN 13
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars Size/Chars Prefix Char Suffix Char Strip Leading Strip Trailing
0 0 0 0
Range 0-255 0-255 0-127 0-127
Prefix Char This character, if non-zero, is added before a successfully decoded bar code. Enter the ASCII decimal value of this character from 0 to 255. Enter a value of “0” (zero) if no prefix is to be added.
Suffix Char This character, if non-zero, is added after a successfully decoded bar code. Enter the ASCII decimal equivalent of this character from 0 to 255. Enter a value of “0” (zero) if no suffix is to be added.
Teklogix 7035, 8255 & 8260 Terminals User Manual
141
Page 168
Chapter 7: Setting Parameters EAN 13
Strip Leading This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Notes: 1.
The appended character is treated as any other keyboard character. For example, if <DEL> is pressed, the usual action for that key is performed. With ANSI emulation, the terminal transmits the escape sequence associated with the function immediately after the bar code data. 2. For Code 39 bar codes, the “AIAG Strip” is performed before the “Strip Leading”.
Strip Trailing The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
Addendum Important:
Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 135) must be set to “Y”.
An addendum is a separate bar code, supplementary to the main bar code. This parameter provides three options: Disabled, Options and Required. Depending on the value chosen for this parameter, an addendum is recognized or ignored. When “Addendum” is set to Disabled, the scanner does not recognize an addendum. If this parameter is set to Optional, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required, the scanner does not accept the main bar code without an addendum.
142 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 169
Chapter 7: Setting Parameters EAN 8
7.6.3.4 EAN 8 EAN 8 Include Chk Size/Chars Addendum
Y » Disable
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 141.
Addendum Important:
Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 135) must be set to “Y”.
Refer to "Addendum" on page 142.
7.6.3.5 UPC A UPC A Inc Num Sys Include Chk Size/Chars Addendum
N N » Disabled
Inc Num Sys If this parameter is enabled (set to “Y”), the number system digit is included with the decoded bar code data.
Include Chk If this parameter is enabled (set to “Y”), the check digit will be included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 141. Teklogix 7035, 8255 & 8260 Terminals User Manual
143
Page 170
Chapter 7: Setting Parameters UPC E
Addendum Important:
Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 135) must be set to “Y”.
Refer to “Addendum” on page 142.
7.6.3.6 UPC E UPC E Exp to UPC A Inc Num Sys Include Chk Size/Chars Addendum
Y Y Y » Disable
Exp to UPC A Setting this parameter to “Y” enables a non-standard decoding that returns 12 digits from the 6 digit UPC E bar code.
Inc Num Sys If this parameter is enabled (set to “Y”), the number system digit is included with the decoded bar code data.
Include Chk When enabled, the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 141.
Addendum Important:
Before “Addendum” can take effect, the “Short Code” parameter in the Options menu (see page 135) must be set to “Y”.
Refer to “Addendum” on page 142.
144 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 171
Chapter 7: Setting Parameters Codabar
7.6.3.7 Codabar Codabar Size/Chars
»
Size/Chars See “Size/Chars” beginning on page 138.
7.6.3.8 Code 93 Code 93 Size/Chars
»
Size/Chars See “Size/Chars” beginning on page 138.
7.6.3.9 Code 11 Code 11 1 Chk Digit 2 Chk Digits Include Chk Size/Chars
N Y N »
1 Chk Digit If this parameter is enabled (set to “Y”), it is assumed that the last digit is a check digit.
2 Chk Digits If this parameter is enabled (set to “Y”), it is assumed that the last two digits are check digits.
Include Chk If “Include Chk” is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 138.
Teklogix 7035, 8255 & 8260 Terminals User Manual
145
Page 172
Chapter 7: Setting Parameters I 2 of 5
7.6.3.10 I 2 of 5 I 2 of 5 Mod 10 Chk ITF Chk Include Chk Size/Chars
N N N »
Mod 10 Chk If this parameter is enabled (set to “Y”), the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.
ITF Chk If this parameter is enabled (set to “Y”), the ITF-14/16 Mod10 check digit is calculated.
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 138.
7.6.3.11 MSI/PLESSY MSI/PLESSY 1 Chk Digit Include Chk Size/Chars
Y N »
1 Chk Digit If this parameter is enabled (set to “Y”), it is assumed that the last digit is a check digit.
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 138. 146 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 173
Chapter 7: Setting Parameters D 2 of 5
7.6.3.12 D 2 of 5 D 2 of 5 Mod 10 Chk ITF Chk Include Chk Size/Chars
N N N »
Mod 10 Chk If this parameter is enabled (set to “Y”), the Mod 10 check digit is calculated. This calculation is the same as the Code 39 Mod 10 check digit.
ITF Chk If this parameter is enabled (set to “Y”), the ITF-14/16 Mod10 check digit is calculated.
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 138.
7.6.3.13 IATA 2 of 5 IATA 2 of 5 Mod 10 Chk ITF Chk Include Chk Size/Chars
N N N »
Mod 10 Chk If this parameter is enabled (set to “Y”), the Mod 10 check digit is calculated.
ITF Chk If this parameter is enabled (set to “Y”), the ITF-14/16 Mod10 check digit is calculated.
Teklogix 7035, 8255 & 8260 Terminals User Manual
147
Page 174
Chapter 7: Setting Parameters Applications
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
Size/Chars See “Size/Chars” beginning on page 138.
7.7 Applications “TESS” and “ANSI” applications require unique names so that several different sessions of “TESS” and “ANSI” can operate simultaneously. The 7035, 8255 and 8260 terminals can support up to 4 sessions at one time. Applications Name #1 Widget Type #1 ANSI Settings #1 » . . . Name #4 Type #4 Settings #4
Important:
Range see text TESS/ANSI see text
These applications will become active only after the changes made in the Application screen are saved by pressing <F4> – the SAVE key.
148 Teklogix 7035, 8255 & 8260 Terminals User Manual