Page 155
Chapter 7: Setting Parameters Font Size
7.5.8 Font Size Note: This “Font Size” feature is used by the DOS command line or by applications that do not provide font adjustment parameters. Tekterm is equipped with its own font sizing capabilities. ANSI Font Sizes are described under “Font Size” on page 154. TESS Font Sizes are described under “Font Size” on page 164. Important:
Because the 8260 vehicle-mount terminal is equipped with a full size – 25 x 80 – display, full screens can easily be displayed without reducing the font size. For this reason, the 8260 does not provide a Font menu.
This parameter is used to change the font size displayed on 7035 hand-helds and 8255 vehicle-mounts. Font sizes are represented in lines x characters (rows x columns). Font availability varies depending on the type of terminal. •
Press the <RIGHT> arrow key to scroll through the options.
7.5.9 Cursor Type Note: This “Cursor Type” parameter is used by the DOS command line or by applications that do not provide cursor adjustment parameters. Tekterm is equipped with its own cursor commands. This parameter allows you to choose how you want the terminal cursor displayed. You can choose either an Underline or Block cursor. •
Press the <RIGHT> arrow key to scroll through and choose an option.
7.5.10 Palette Remap A DOS-based application generally uses a VGA colour palette. On Teklogix terminals, these colours are converted to grey scale with varying degrees of success. While grey scale displays well on a 7035 hand-held terminal, it does not display as well on an 8255 LCD or an 8260 vehicle-mount terminal. The “Palette Remap” parameter allows you to substitute default application colours with colours that will display well on your Teklogix terminal. Note: All built-in Teklogix software uses only intense white (VGA index 15) and black (VGA index 0), both of which display well on Teklogix terminals.
Teklogix 7035, 8255 & 8260 Terminals User Manual
129
Page 156
Chapter 7: Setting Parameters Watchdog Timer The values on the left-hand side of the “Palette Remap” screen represent the original VGA palette; these values cannot be changed. The values on the right-hand side of this screen can be altered to remap colours as they reach your Teklogix terminal display. For example, suppose that you want your terminal to always replace the colour red with the colour black. You need to change the red colour value of 4 to the black colour value of 0. Palette Remap [0] Black [0] [1] Blue [1] [2] Green [2] [3] Cyan [3] [4] Red [4] [5] Magenta [5] [6] Brown [6] [7] Lt Grey [7] [8] Dark Grey [8] [9] Lt Blue [9] [a] Lt Green [a] [b] Lt Cyan [b] [c] Lt Red [c] [d] Lt Magenta [d] [e] Yellow [e] [f] White [f] To remap a colour: • Highlight the colour you want to remap, and press the <RIGHT> or <LEFT> arrow key until the colour value you want is displayed. •
Press <F4> to save your changes, and reset the terminal. (See page 119 for terminal reset information.)
7.5.11 Watchdog Timer Setting this parameter to Enabled signals the terminal to reboot automatically when control of the terminal is not periodically returned to a system monitor program (running in the background). This allows for recovery from programs that “crash” or “hang” the terminal. If “Watchdog Timer” is set to Disabled, the terminal will not reboot automatically under the circumstances described above.
130 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 157
Chapter 7: Setting Parameters Power – 7035 Only
7.5.12 Power – 7035 Only Power CPU speed Power down Power off
33MHz 4 mins 1 hour
Range 8, 16, 33MHz see text see text
CPU Speed Important:
Changing the CPU speed can invalidate FCC approvals. Cisco and Lucent radios are approved for 33Mhz. The Narrow Band radio is only approved for 8 MHz. This parameter allows you to change the CPU speed your terminal uses. Allowable values are: 8MHz, 16MHz and 33MHz.
Power Down When the amount of time specified in the “Power Down” parameter expires without any activity, the terminal goes into suspend mode, a power-saving mode. Pressing <ENTER/ON> reinstates full power mode. The possible values for this parameter are: Disabled, 1 min, 2 mins, 4 mins, 8 mins, 16 mins, 32 mins and 60 mins.
Power Off Important:
The value assigned for this parameter is not recognized until the value in the “Power Down” parameter has expired. When the time specified for the “Power Off” parameter has expired, the terminal turns off. A full reboot is required to return the terminal to full operating mode. The allowable values for this parameter are: Disabled, 1 min, 8 mins, 16 mins, 32 mins, 1 hour, 2 hours and 4 hours. This timeout occurs whether the terminal is turned on or off. That is, even if the terminal is switched off, it will return to its last operating state when switched on. If it is left ‘off’ for the time period specified by this parameter, a full reboot will occur when switched back on.
7.5.13 Serial Number This parameter identifies the terminal serial number. Normally, this value is set at the factory. However, the serial number can also be defined in the field using a serial download cable and a terminal connection to PMENU. Note: “Serial Number” is saved in EEPROM; it will not be erased if the parameter values are defaulted. Teklogix 7035, 8255 & 8260 Terminals User Manual
131
Page 158
Chapter 7: Setting Parameters Keyboard Type – Vehicle-Mounts Only
7.5.14 Keyboard Type – Vehicle-Mounts Only Teklogix offers two types of vehicle-mount keyboard types – an ‘F1 To F6’ and an ‘F1 to F10’ keyboard type. The keys on these two keyboard are mapped differently, and the ‘Keyboard Type’ parameter allows you to specify the keyboard type your terminal is using – ‘F1 To F6’ or ‘F1 to F10’. Note: The value assigned to this parameter is saved until you change it; that is, it will not change when the <F3> – Default – key is pressed.
7.6 Scanner Scanner Type Options Barcode
» » »
7.6.1 Type Type
Range
Internal Standard Standard, Long Range, High Vis, 2-D External Non-Decoded Non-Decoded, Wand
The Type sub-menu is used to indicate the type of internal and/or external scanner being used. The 7035 hand-held terminal can support both an internal and an external scanner at the same time.
Internal – 7035 Only Note: If you are using an Advanced Long Range (ALR) scanner, choose the Long Range setting. If you are using an High Performance (HP) scanner, choose either the Standard or High Visibility setting. Keep in mind also that if you are using a 2-D scanner, ‘Console 2’ in the Ports menu is set to ‘Disable’ by default – it cannot be configured. The “Internal” parameter must match the type of internal scanner installed in the 7035 – Long Range, High Visibility, Standard or 2-D. If an internal scanner has not been installed, set this parameter to None.
132 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 159
Chapter 7: Setting Parameters Options Note: The 2-D internal scanner is configured by the 7035 software on startup. Beyond selecting the 2-D scanner type, no configuration is required. However, the scan engine can be misconfigured if you scan a Symbol SE 2223 configuration bar code. To reset the engine to the appropriate default 2-D settings, scan the ‘Set All Defaults’ bar code below.
Important:
When you select 2-D as the internal scanner, the Console 2 port is disabled.
External The “External” (external) parameter must match the type of external scanner attached to the terminal – Wand or Non-Decoded. If an external scanner is not being used, set this parameter to None.
7.6.2 Options Options Translate Verify Security Short Code Click Time Click Data Scan Result Scan Indic Result Time Dot Time
» 0 0 N 250 Y Y 0 2.0 sec
Range see text 0..15 0..99 Y/N 0..1000 0..255 Y/N Y/N 0..20 0..3.0 Sec
Teklogix 7035, 8255 & 8260 Terminals User Manual
133
Page 160
Chapter 7: Setting Parameters Translate
7.6.2.1 Translate In Out . . . In Out Important:
Translate #1 #1
#8 #8
For detailed instructions on inserting characters or special keys (e.g., <ENTER>, <DEL>, etc.) in these fields, refer to "Global Macros" on page 182 to page 185. HOWEVER, keep in mind that these string entry fields do NOT accept Function keys and Arrow keys.
In #n This string entry parameter is compared with the decoded bar code reading. If there is a match, the “Out” string is translated into the decoded bar code. The first character of the “In” string specifies where the rest of the string can occur within the decoded bar code reading. The possible values for this character include: b Compare with the beginning of decoded bar code. e Compare with the end of decoded bar code. x Compare with the entire decoded bar code. a Compare anywhere within the decoded bar code (default). If the first character is none of ‘b’, ‘e’, ‘x’ or ‘a’, the character is assumed to be an ‘a’ and is stripped from the rest of the “In” entry. Note: Translation of the decoded bar code occurs after all other modifications to the bar code have been done (e.g., prefix char, suffix char, strip, etc.).
Out #n If there is a match between the decoded bar code and the corresponding “In” string, the decoded bar code will be translated into the “Out” string. This string entry parameter can be null, or it may contain any combination of standard and special characters (e.g., function keys, <ENTER>, etc.).
134 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 161
Chapter 7: Setting Parameters Other Options
7.6.2.2 Other Options Verify The value entered for this parameter determines the number of correct additional decodes required after the initial decode before a bar code is accepted. The allowable range is 0 to 15. Higher values significantly increase the time it takes to decode a bar code.
Security This parameter controls the tolerance for decoding edge-to-edge bar codes (Code 93, Code 128, UPC/EAN). The allowable value is 0 to 99. Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code.
Short Code When enabled (set to “Y”), this parameter allows scanning of short I 2 of 5 bar codes (2 characters). When “Short Code” is disabled (set to “N”), these short bar codes are rejected. Setting this parameter to “Y” may reduce the robustness of the decoding since the terminal must decode more potential bar codes. For this reason, it is not recommended that “Short Code” be enabled for general-purpose bar codes with 4 or more characters.
Click Time Note: This parameter only effects terminals using long-range scanners. This parameter controls the maximum gap time (in milliseconds) for a double-click. If the time between the first and second clicks of the scanner trigger is within this time, it is considered a double-click. The allowable range is 0 to 1000. A value of zero disables this feature. A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter (see page 136). When a value is not assigned for the “Click Data”, double-clicking the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click Data” value rather than initiating a scan.
Teklogix 7035, 8255 & 8260 Terminals User Manual
135
Page 162
Chapter 7: Setting Parameters Other Options
Click Data For both integrated and external scanners, this parameter determines which character is sent to TESS or ANSI following a double-click. Enter the ASCII value of the character desired from 0 to 255. You can also press the <LEFT> and <RIGHT> arrow keys to scroll through a set of ASCII characters not available from the keyboard.
Scan Result – 7035 Only When this parameter is enabled (set to “Y”), the type of bar code and the result of the scan appear on the terminal screen. Note that this information is only displayed after a successful decode and only as long as the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen.
Scan Indic – 7035 Only When this parameter is enabled (set to “Y”), the laser warning logo appears on the display whenever the scanner is activated. For the Teklogix 7035-I integrated terminal, this message is mandatory and appears even if this parameter is disabled (set to “N”).
Dot Time – 7035 Only Important:
“Dot Time” only appears in the Scanner Options menu when either “Long Range” or “High Vis” is selected as the internal scanner option. Internal scanner options are described on page 132 under the heading “Internal”.
The value selected for “Dot Time” determines how long the targeting dot remains on before the scanner switches to a normal scan sweep. The allowable values are: 0, 0.1, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 seconds.
Result Time The value assigned to the “Result Time” parameter determines how long the scan results of a successful scan are displayed on the terminal screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter. Note: To remove the scan result from the screen before the “Result Time” has expired, perform an unsuccessful scan.
136 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 163
Chapter 7: Setting Parameters Barcode
7.6.3 Barcode All the available bar code symbologies can be selected from this menu. For each symbology, there are options in a sub-menu. The terminal automatically discriminates between the selected codes. Some restrictions may apply. Important:
To improve the decode speed and performance, enable (set to “Y”) only those codes that are required by the application.
Barcode Code 39 Code 128 EAN 13 EAN 8 UPC A UPC E Codabar Code 93 Code 11 I 2 of 5 MSI/PLESSY D 2 of 5 IATA 2 of 5
Y » Y » Y » Y » Y » Y » N » N » N » N » N » N » Y »
Code 39 Full Ascii Mod 43 Chk Mod 10 Chk Include Chk AIAG Strip Err Accept Size/Chars
N N N N N N »
7.6.3.1 Code 39
Full Ascii If this parameter is enabled (set to “Y”), the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.
Teklogix 7035, 8255 & 8260 Terminals User Manual
137
Page 164
Chapter 7: Setting Parameters Code 39
Mod 43 Chk If this parameter is enabled (set to “Y”), the Mod 43 check digit is calculated.
Mod 10 Chk If this parameter is enabled (set to “Y”), the Mod 10 check digit is calculated.
Include Chk If this parameter is enabled (set to “Y”), the check digit is included with the decoded bar code data.
AIAG Strip If this parameter is enabled (set to “Y”), the AIAG data identifier is removed from each decoded Code 39 label. The data identifier occurs in the first position next to the Code 39 start character. It can be a single alphabetic character or a series of numeric digits followed by an alphabetic character. This identifier defines the general category or specific use of the data contained in the rest of the bar code. Note: This parameter should not be used in conjunction with the TESS AIAG feature. This is because the terminal performs the strip function before it processes the data through the AIAG feature; if the prefix is stripped, the data is not identified as AIAG.
Err Accept If the “Err Accept” and “AIAG Strip” parameters are enabled (set to “Y”), all label data without an AIAG identifier character is accepted. If the “Err Accept” parameter is disabled (set to “N”) and the “AIAG Strip” parameter is enabled (set to “Y”), the label data is not accepted.
Size/Chars Size/Chars Field Size Prefix Char Suffix Char Strip Leading Strip Trailing
138 Teklogix 7035, 8255 & 8260 Terminals User Manual
0 0 0 0 0
Range 0-99 0-255 0-255 0-127 0-127